Laser based smart displacement sensor
SIcon/01. Sensors for Industry Conference. Proceedings of the First ISA/IEEE. Sensors for Industry Conference (Cat. No.01EX459), 2002The paper presents a displacement measuring system based on one optical emitter (laser diode), two optical sensors and on a smart structure used for sensor data processing. The system is designed around the PIC16F877 8-bit microcontroller that powers the sensors, acquires data from the sensors and performs the intelligent processing based on a neural ...
O. Postolache, M. Pereira, P. Girao
openaire +1 more source
Measurement science and technology, 2021
In practical applications, some special working scenarios need to take into account both narrow space and extreme temperature, which puts more strict requirements on the size and temperature adaptability of the laser triangulation displacement sensor ...
Zhuojiang Nan, T. Wei, Zhao Hui
semanticscholar +1 more source
In practical applications, some special working scenarios need to take into account both narrow space and extreme temperature, which puts more strict requirements on the size and temperature adaptability of the laser triangulation displacement sensor ...
Zhuojiang Nan, T. Wei, Zhao Hui
semanticscholar +1 more source
Laser displacement sensor with application to gravitational radiation detection
Applied Optics, 1980The principles of operation of a novel laser displacement sensor are described. The intended application of the sensor is to measure displacements induced by gravitational radiation. The laser sensor is composed of three coupled cavities, defined by two laser mirrors and the mirrors of a Fabry-Perot etalon placed inside the laser cavity.
M, Weksler, Z, Vager, G, Neumann
openaire +2 more sources
Measuring leg ulcers using a laser displacement sensor
Physiological Measurement, 1994A non-contact method for the measurement of a skin ulcer's area and volume has been developed. A commercially available laser displacement sensor is scanned across the ulcer's surface to produce a displacement image. From this image the healthy normal skin's surface is reconstructed and the area and volume found.
D A, Ibbett +4 more
openaire +2 more sources
Measurement, 2019
The laser displacement sensor scan technique proposed in the present study helps to calculate the corrosion rate (CR), and subsequently, determine the susceptibility to intergranular corrosion, without preparing separate samples for the weld zone (WZ ...
Kalinga Simant Bal +2 more
semanticscholar +1 more source
The laser displacement sensor scan technique proposed in the present study helps to calculate the corrosion rate (CR), and subsequently, determine the susceptibility to intergranular corrosion, without preparing separate samples for the weld zone (WZ ...
Kalinga Simant Bal +2 more
semanticscholar +1 more source
Modification of displacement signals collected by laser sensors
2009 9th International Conference on Electronic Measurement & Instruments, 2009Laser displacement sensors are highly-frequent used instrument for dynamic response measurement in wind tunnel tests. The fundamental performances of three types of laser sensors used in wind tunnel laboratory are introduced, and several factors for influencing precision are reviewed.
Fuyou Xu +3 more
openaire +1 more source
A type of portable micro-EDXRF spectrometer with laser displacement sensor
Nuclear Instruments and Methods in Physics Reseach B, 2019A portable micro energy dispersive X-ray fluorescence spectrometer with Laser Displacement Sensor (LDS) is reported in this paper. Due to irregular or curved surface of archaeological object, the distances between the irradiation spot of sample and exit ...
Du Zeming +4 more
semanticscholar +1 more source
Temperature Compensation of Laser Triangular Displacement Sensor
2019 Chinese Automation Congress (CAC), 2019The measurement precision of the laser triangulation displacement sensor will be decreased with temperature, its application areas have been restricted for a long time. Three main factors affecting measurement accuracy were analyzed and two algorithms were proposed in this paper to compensate for the temperature error.
Zhi Li +4 more
openaire +1 more source
Surface profile measurement using a laser displacement sensor
A three dimensional surface profiling system was developed by integrating a Confocal laser displacement sensor with a X-Y scanning stage. The system allowed to scan a sample point by point over a selected area. For each point on the sample X, Y and Z values were collected.
Talukdar, Amitava
openaire +2 more sources
Integration of vision and laser displacement sensor for efficient and precise digitizing
Proceedings of 1994 IEEE International Conference on MFI '94. Multisensor Fusion and Integration for Intelligent Systems, 1996This paper presents a new digitizing technique which integrates computer vision methods, such as the photometric stereo approach, with the laser displacement sensors (LDS). The curvature at each point of the surface can be measured cost-effectively by the photometric stereo approach.
Chia-Chun Huang, Yuan F. Zheng
openaire +1 more source