Results 41 to 50 of about 32,417 (310)

A Balanced Dual-Intracavity Dual-Mode Interlocking Method for Fiber Laser Self-Reference Wavelength Stabilization

open access: yesIEEE Photonics Journal
The laser frequency stabilization technology is very important in the development of laser applications, and the improvement of this technology has tend to further expectations for portability and low cost, in addition to the realization of strict ...
Liuxin Zhang   +9 more
doaj   +1 more source

Impact analysis of cavity length on transfer cavity frequency locking system for atomic inertial measurement device

open access: yesAIP Advances, 2020
In this work, an efficient method for frequency stabilization of a highly off-resonant laser in a spin-exchange relaxation-free atomic inertial sensor is proposed.
Xiufei Li   +5 more
doaj   +1 more source

Laser frequency stabilization and tuning.

open access: yesThe Review of Laser Engineering, 1987
Development and recent progress of laser frquency control of gas, dye, and semiconductor lasers are reviewed. Narrowing of laser spectral width, stabilization of the center frequency and freqency tuning with high frequency stability are described. Ultrahigh frequency stabilties of 3×10-16 for a He-Ne laser and 10-14-10-15 for an Al Ga As laser has been
TAKO, Toshiharu, AKIMOTO, Yoshiaki
openaire   +2 more sources

Confocal Fabry-Perot interferometer for frequency stabilization of laser

open access: yes, 2011
The frequency shift of laser source of Doppler lidar is required in the range of a few megahertzs. To satisfy this demand, a confocal Fabry-Perot (F-P) interferometer was manufactured as the frequency standard for frequency stabilization. After analyzing
Ruan, P.   +3 more
core   +1 more source

USP29‐regulated noncanonical stabilization of the hypoxia‐inducible factor‐α in aggressive prostate cancer

open access: yesMolecular Oncology, EarlyView.
We identify USP29 as the only DUB mirroring CA9 expression, a marker of hypoxia and HIF pathway activation associated with PCA aggressiveness. USP29 stabilizes HIF‐1α and HIF‐2α via a noncanonical mechanism that is independent of PHD/pVHL activity yet relies on proteasomal regulation, establishing USP29 as a previously unrecognized regulator of hypoxic
Amelie S Schober   +16 more
wiley   +1 more source

Locking Multi-Laser Frequencies to a Precision Wavelength Meter: Application to Cold Atoms

open access: yesSensors, 2021
We herein report a simultaneous frequency stabilization of two 780-nm external cavity diode lasers using a precision wavelength meter (WLM). The laser lock performance is characterized by the Allan deviation measurement in which we find σy=10−12 at an ...
Junwoo Kim   +8 more
doaj   +1 more source

Large‐scale bidirectional arrayed genetic screens identify OXR1 and EMC4 as modifiers of αSynuclein aggregation

open access: yesFEBS Open Bio, EarlyView.
Activation of the mitochondrial protein OXR1 increases pSyn129 αSynuclein aggregation by lowering ATP levels and altering mitochondrial membrane potential, particularly in response to MSA‐derived fibrils. In contrast, ablation of the ER protein EMC4 enhances autophagic flux and lysosomal clearance, broadly reducing α‐synuclein aggregates.
Sandesh Neupane   +11 more
wiley   +1 more source

Excited state spatial distributions in a cold strontium gas [PDF]

open access: yes, 2012
This thesis describes the development of a new technique for measuring the spatial distribution of Rydberg atoms in a cold strontium gas. Strontium atoms are cooled and trapped in a magneto-optical trap and coherently excited to Rydberg states in a two ...
LOCHEAD, GRAHAM
core  

Hyperosmotic stress‐induced redistribution of pre‐mRNA cleavage factor I subunits is associated with shifts in alternative polyadenylation

open access: yesFEBS Open Bio, EarlyView.
Hyperosmotic stress triggers the relocation of the CFIm complex from the nucleus to the cytoplasm. This shift creates a nuclear ‘stoichiometric bottleneck’, limiting CFIm availability for mRNA processing. Consequently, specific mRNAs like NUDT21 and DICER1 undergo targeted 3′UTR shortening, demonstrating how spatial protein dynamics drive rapid ...
Hitomi Soumiya   +2 more
wiley   +1 more source

Absolute Frequency Readout of Cavity against Atomic Reference

open access: yesRemote Sensing, 2022
Future space-based geodesy missions such as the Mass Change Mission and the Next Generation Gravity Mission are expected to rely on laser ranging as their primary instrument.
Emily Rose Rees   +3 more
doaj   +1 more source

Home - About - Disclaimer - Privacy