Results 11 to 20 of about 3,181 (183)
Linac performance benchmarking: Feasibility of a web-based tool for comparison of local machine performance check (MPC) results with the global community. [PDF]
Abstract Background Varian machine performance check (MPC) is a manufacturer integrated quality control system included as standard for TrueBeam and Halcyon linear accelerators (linacs) to assess performance using a broad range of geometric and beam tests.
May L +12 more
europepmc +2 more sources
Seven Level Inverter LCL Filter
The paper presents the controlling of current in single phase grid connected seven level multiinverter with boostup operation. Here we get output as 1.5 times of input using charge pump principle with less harmonic distortions. By using LCL filter we can control the current which removes the LCL resonance and maintain the stability at different ...
Yamuna Pagidela, Sailaja K
openaire +1 more source
Phase Shifting Transformer-LCL (PST-LCL) Filter: Modeling and Analysis [PDF]
Power converters have been widely used in power systems to improve the quality and magnitude of the power drawn from renewable energy sources. An LCL filter for connection of an inverter to the grid is often used to reduce the harmonics generated by the inverter.
Chitsazan, Mohammad Amin +1 more
openaire +1 more source
Transformer and LCL Filter Design for DPFCs [PDF]
Flexible AC Transmission Systems (FACTS) can be used for power flow control in AC transmission grids, allowing simultaneous control of the bus voltage and line active and reactive power. However, due to high costs and reliability concerns, the application of this technology has been limited in such applications.
Ivo M. Martins +3 more
openaire +4 more sources
Research on Current Harmonic Suppression Strategy of the LCL Grid-connected Inverter [PDF]
The increasing number of nonlinear devices increased the harmonic content of grid voltage background and led to the grid-connected current distortion of inverter.
LIU Haiyang +4 more
doaj +1 more source
Digital notch filter based active damping for LCL filters [PDF]
LCL filters are widely used in Pulse Width Modulation (PWM) inverters. However, it also introduces a pair of unstable resonant poles that may challenge the controller stability. The passive damping is a convenient possibility to tackle the resonance problem at the cost of system overall efficiency.
Yao, Wenli +3 more
openaire +2 more sources
Modeling and Stability Analysis of
Due to the advantages of superior harmonics attenuation ability and reduced size, the LCL filter has been widely adopted to interface between the inverter and the grid for improving the quality of injected grid currents.
Yang Han +6 more
doaj +1 more source
An Evolutionary Annealing–Simplex Method for Inductance Value Selection for LCL Filters
Grid-connected voltage-source inverters (VSIs) have evolved over the past years for the interconnection of renewable energy sources with the grid to satisfy the increased electrical load demand and utilize clean carbon-free energy. However, VSIs suffer a
Xingyu Yang +3 more
doaj +1 more source
An Electrical Machine with Integrated Drive LCL Filter Components [PDF]
In recent years, integrated passive components technology has gained significant popularity in integrated drives research. An integrated drive may be considered to be a full mechanical integration of the machine, power electronic converter and passive components into a single package. This approach is important for applications such as traction motors,
Mohamed, M.A. +4 more
openaire +1 more source
High-order filters, such as LCL, are more commonly employed in grid-connected inverters (GcIs) as an interference element for the better attenuation of switching harmonics.
Muhammad Saleem +3 more
doaj +1 more source

