Results 11 to 20 of about 575,698 (128)
Influence of LCL Output Filter Parameter Changing on D-STATCOM Compensation Characteristics
Aim at the problem of D-STATCOM output containing plenty of switching ripple, LCL filter was designed. Influence of LCL filter parameters on the compensation characteristic of D-STATCOM was studied. Considering the compensation capacity of the D-STATCOM,
ZHANG Xingru
doaj +2 more sources
Effect of Line Impedance on the Stability of Shunt Active Power Filter Based on LCL Filter
When shunt active power filter based on LCL filter is used for voltage source type harmonic source, the line and load impedances will not only cause the harmonic amplification but also the stability problem based on current tracking.
REN Lei, YUN Pingping
doaj +2 more sources
Robust repetitive feedback control of a three-phase grid connected inverter [PDF]
This paper discusses the design of a repetitive feedback controller for a grid-connected two-level three-phase voltagesource inverter connected between a DC source and the grid through an LCL filter.
Sharkh, S.M. +4 more
core +2 more sources
LCL Filter Design for Grid Connected Three-Phase Inverter [PDF]
2nd International Symposium on Multidisciplinary Studies and Innovative Technologies (ISMSIT) -- OCT 19-21, 2018 -- Kizilcahamam, TURKEYDursun, Mustafa/0000-0001-9952-9358WOS: 000467794200011In this study, LCL filter design was performed by simulating ...
Döşoğlu, M. Kenan, Dursun, Mustafa
core +3 more sources
Research on Current Harmonic Suppression Strategy of the LCL Grid-connected Inverter [PDF]
The increasing number of nonlinear devices increased the harmonic content of grid voltage background and led to the grid-connected current distortion of inverter.
LIU Haiyang +4 more
doaj +1 more source
Modeling and Stability Analysis of
Due to the advantages of superior harmonics attenuation ability and reduced size, the LCL filter has been widely adopted to interface between the inverter and the grid for improving the quality of injected grid currents.
Yang Han +6 more
doaj +1 more source
An Evolutionary Annealing–Simplex Method for Inductance Value Selection for LCL Filters
Grid-connected voltage-source inverters (VSIs) have evolved over the past years for the interconnection of renewable energy sources with the grid to satisfy the increased electrical load demand and utilize clean carbon-free energy. However, VSIs suffer a
Xingyu Yang +3 more
doaj +1 more source
With the smart grid revolution, there is a growing interest in the use of power converters associated to LCL filters to interface between the main utility grid and loads or renewable energy sources.
Marwa Ben Said-Romdhane +3 more
doaj +1 more source
High-order filters, such as LCL, are more commonly employed in grid-connected inverters (GcIs) as an interference element for the better attenuation of switching harmonics.
Muhammad Saleem +3 more
doaj +1 more source
LCL filter is widely used in grid-connected converters for good harmonic mitigation performance. However, resonance poles of LCL filter challenge system stability, especially in a digital control system.
Tingting Gao +3 more
doaj +1 more source

