Results 21 to 30 of about 3,181 (183)
LCL filter is widely used in grid-connected converters for good harmonic mitigation performance. However, resonance poles of LCL filter challenge system stability, especially in a digital control system.
Tingting Gao +3 more
doaj +1 more source
The power delivered by a voltage source inverter needs to be filtered to fulfill grid code requirements. A commonly used filter technology is the LCL-filter.
Christoffer Fjellstedt +2 more
doaj +1 more source
Optimized damping for LCL filters in three-phase voltage source inverters coupled by power grid
The application of LCL filters has become popular for inverters connected to the power grid due to their advantages in harmonic current reductions. However, the power grid in a distribution system is non-ideal, presenting itself as a voltage source with ...
Meng Huang +3 more
doaj +1 more source
This paper proposes a nonlinear decoupled current control scheme for a grid-connected inverter with LCL filter. Decoupling the active and reactive current control channels is one of the main demands in the control of inverters.
Mohamad Amin Ghasemi +3 more
doaj +1 more source
Single-Sensor Control of LCL-Filtered Grid-Connected Inverters [PDF]
Owing to the filter resonance and background harmonics, the current control for the LCL-filtered grid-connected inverter should be carefully designed to ensure stable operation. Prior-art current control methods normally require extra sensors to achieve the damping of the resonance, or sophisticated active damping should be employed.
Mei Su 0001 +7 more
openaire +4 more sources
Distributed static compensators (DSTATCOMs), composed of power converters and passive filters, have been extensively utilized in distribution systems to improve their power quality. For the selection of passive filters, LCL filters with smaller sizes and
Xiangjian Meng, Jingyang Fang
doaj +1 more source
The Proportional Resonant (PR) current controller provides gains at a certain frequency (resonant frequency) and eliminates steady state errors. Therefore, the PR controller can be successfully applied to single grid-connected PV inverter current control.
Ningyun Zhang, Houjun Tang, Chen Yao
doaj +1 more source
Analysis and design of LCL filter based synchronverter [PDF]
Electrical energy generation is evolving from centralized towards distributed energy resources (DER) like wind and solar power plants. In such power systems, new challenges arise for the design of voltage source converter (VSC) control strategies.
Rosso, Roberto +4 more
openaire +1 more source
Ozone generation is a water disinfection method, superior to chlorine in terms of fewer byproducts and no residual taste. However, its high production cost limits its widespread adoption. This paper designs an ozone generation sinusoidal power supply for
Mostafa M. Shibl +3 more
doaj +1 more source
Research on Adaptive Suppression of LCL Converter Resonance Grid-Connected System
LCL-type converters are widely used in grid-connected systems due to their small size and good filtering performance. However, the resonance suppression problem brought by the LCL filter cannot be ignored.
Junwei Li, Yafang Tang, Junke Li
doaj +1 more source