Results 31 to 40 of about 1,710,199 (275)
PWM rectifier LCL filter design for underground mine
The dual PWM variable frequency speed regulation system applied to scraper conveyors, coal shearers and other mechanical equipments needs to be installed a filter on the rectifier grid-side to suppress harmonic currents.
LI Shan1, LIU Xiaodong2, SU Changbo3
doaj +1 more source
Adequate Tuning of LCL filter for Robust Performance of Converter Side Current Feedback Control of Grid Connected Modified–Y-Source Inverter [PDF]
In the grid-tied PV inverter systems, the design of a proper power conditioning system is an important issue to ensure high-quality power injection to the grid.
Navid Rasekh, Majid Hosseinpour
doaj +1 more source
Research on Current Harmonic Suppression Strategy of the LCL Grid-connected Inverter [PDF]
The increasing number of nonlinear devices increased the harmonic content of grid voltage background and led to the grid-connected current distortion of inverter.
LIU Haiyang +4 more
doaj +1 more source
A design methodology for minimum volume of LCL filters applied to grid connected converters is proposed. It combines the determination of filter parameter values (inductances and capacitances) to hardware design (component technology and inductor ...
Pedro C. Bolsi +4 more
semanticscholar +1 more source
Robust repetitive feedback control of a three-phase grid connected inverter [PDF]
This paper discusses the design of a repetitive feedback controller for a grid-connected two-level three-phase voltagesource inverter connected between a DC source and the grid through an LCL filter.
Sharkh, S.M. +8 more
core +1 more source
Modeling and Stability Analysis of
Due to the advantages of superior harmonics attenuation ability and reduced size, the LCL filter has been widely adopted to interface between the inverter and the grid for improving the quality of injected grid currents.
Yang Han +6 more
doaj +1 more source
An Evolutionary Annealing–Simplex Method for Inductance Value Selection for LCL Filters
Grid-connected voltage-source inverters (VSIs) have evolved over the past years for the interconnection of renewable energy sources with the grid to satisfy the increased electrical load demand and utilize clean carbon-free energy. However, VSIs suffer a
Xingyu Yang +3 more
doaj +1 more source
An Electrical Machine with Integrated Drive LCL Filter Components [PDF]
In recent years, integrated passive components technology has gained significant popularity in integrated drives research. An integrated drive may be considered to be a full mechanical integration of the machine, power electronic converter and passive components into a single package. This approach is important for applications such as traction motors,
Mohamed, M.A. +4 more
openaire +1 more source
In distributed power generation systems, grid-connected inverters are becoming an attractive means of delivering the energy generated from renewable sources into the grid.
Abu Sufyan +6 more
semanticscholar +1 more source
High-order filters, such as LCL, are more commonly employed in grid-connected inverters (GcIs) as an interference element for the better attenuation of switching harmonics.
Muhammad Saleem +3 more
doaj +1 more source