Results 31 to 40 of about 1,577,043 (232)
LCL filter is widely used in grid-connected converters for good harmonic mitigation performance. However, resonance poles of LCL filter challenge system stability, especially in a digital control system.
Tingting Gao +3 more
doaj +1 more source
This paper proposes a nonlinear decoupled current control scheme for a grid-connected inverter with LCL filter. Decoupling the active and reactive current control channels is one of the main demands in the control of inverters.
Mohamad Amin Ghasemi +3 more
doaj +1 more source
Distributed static compensators (DSTATCOMs), composed of power converters and passive filters, have been extensively utilized in distribution systems to improve their power quality. For the selection of passive filters, LCL filters with smaller sizes and
Xiangjian Meng, Jingyang Fang
doaj +1 more source
– In this work, it is presented a new direct discrete-time robust adaptive PI (Proportional Integral) Controller for grid-injected current control loop of a voltage source converter with LCL filter.
P. Evald +3 more
semanticscholar +1 more source
Active Power Filter LCL Filter Insertion Loss Calculation Analysis
This paper introduces a new approach for active power filters LCL filter insertion loss calculation, treating it as two port T-network and describing it using scattering and impedance parameters. There is proposed usage of line impedance stabilization network in frequency range over 9kHz to enable insertion loss calculation neglecting mains impedance ...
G. Asmanis, O. Krievs, A. Asmanis
openaire +1 more source
Optimized damping for LCL filters in three-phase voltage source inverters coupled by power grid
The application of LCL filters has become popular for inverters connected to the power grid due to their advantages in harmonic current reductions. However, the power grid in a distribution system is non-ideal, presenting itself as a voltage source with ...
Meng Huang +3 more
doaj +1 more source
LCL Interface Filter Design for Shunt Active Power Filters
This paper is focused on finding the parameters of a second order interface filter connected between the power system and the shunt active filter based on switching frequency of the active filter. Many publications on power active filters include various design methods for the interface inductive filter which take into account the injected current and ...
DOBRICEANU, M. +3 more
openaire +2 more sources
Single-Sensor Control of LCL-Filtered Grid-Connected Inverters [PDF]
Owing to the filter resonance and background harmonics, the current control for the LCL-filtered grid-connected inverter should be carefully designed to ensure stable operation. Prior-art current control methods normally require extra sensors to achieve the damping of the resonance, or sophisticated active damping should be employed.
Mei Su +7 more
openaire +3 more sources
The Proportional Resonant (PR) current controller provides gains at a certain frequency (resonant frequency) and eliminates steady state errors. Therefore, the PR controller can be successfully applied to single grid-connected PV inverter current control.
Ningyun Zhang, Houjun Tang, Chen Yao
doaj +1 more source
A model-free direct predictive grid-current control strategy for grid-connected converter with an inductance-capacitance-inductance filter [PDF]
The disadvantages of the conventional model predictive current control method for the grid-connected converter (GCC) with an inductance-capacitance-inductance (LCL) filter are a large amount of calculation and poor parameter robustness.
Leilei Guo +4 more
doaj +1 more source

