Results 121 to 130 of about 27,943 (287)

Mutual interference effects in closely-located HDR and LDR WPANs

open access: yes, 2009
Wireless Personal Area Networks (WPANs) are short-range ad-hoc networks centered around a person that make use of unlicensed bands for data transmission.
Prasad, Ramjee   +9 more
core   +1 more source

Dynamic modulated arc therapy (DMAT): A time‐aware, modulation‐steered optimization framework for next‐generation radiotherapy delivery

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 9, September 2026.
Abstract Background Conventional VMAT optimization largely treats delivery time and deliverability as emergent properties of simplified, control‐point‐centric models that often ignore finite acceleration and other dynamic limits. As modern linacs continue to increase maximum axis speeds and dose rates, there is a growing need for a planning paradigm ...
Taoran Li   +12 more
wiley   +1 more source

Clinical in‐vivo dosimetry for total skin electron therapy using gafchromic™ EBT4 film

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 9, September 2026.
Abstract Background Total skin electron therapy (TSET) is a standard treatment for cutaneous T‐cell lymphoma. Due to the complex patient positioning and irregular body contours, robust in‐vivo dosimetry (IVD) is essential to verify dose uniformity. While thermoluminescent dosimeters (TLDs) are traditional standard, their utility is hindered by labor ...
Zhexuan Zhang   +5 more
wiley   +1 more source

Gending Klasik"Ldr. Asih Pl.Br"

open access: yes, 2003
Gending Klasik"Ldr.
Subono, Blacius, Rustopo
core   +1 more source

Dosimetric impact of aperture‐restricted VMAT on heart dose in breast cancer treated with regional nodal irradiation

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 9, September 2026.
Abstract Background Volumetric modulated arc therapy (VMAT) is increasingly used for breast and chest wall (CW) treatment with regional nodal irradiation (RNI) because of its ability to sculpt dose around complex target volumes. However, VMAT can increase low‐dose radiation to surrounding normal tissues and particularly increase cardiac dose.
Anh Hong Duong   +16 more
wiley   +1 more source

A Monte Carlo based dose verification tool for an HDR Ir‐192 brachytherapy source and its evaluation on extremity malignancies

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 9, September 2026.
Abstract Background TG‐43 formalism dose calculation for brachytherapy with the homogeneous water‐based assumption is widely used, which can lead to dose inaccuracy in treatment planning. Purpose Extremity malignancies are also treated with high‐dose‐rate (HDR) 192Ir interstitial brachytherapy, a treatment site that has not been specifically ...
Peixiong Li   +10 more
wiley   +1 more source

The future of brachytherapy physics: Innovation, quality, and the next generation of clinical practice

open access: yes
Journal of Applied Clinical Medical Physics, Volume 27, Issue 10, October 2026.
Nataliya Kovalchuk   +5 more
wiley   +1 more source

Quantitative Cherenkov‐excited fluorescence emission dosimetry for HDR Co‐60 brachytherapy: Calibration and planar validation against TPS

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 9, September 2026.
Abstract Background Accurate dose verification in High‐Dose‐Rate (HDR) brachytherapy presents a significant challenge due to steep dose gradients and the absence of beam collimation. Conventional quality assurance (QA) methods typically rely on point detectors or film‐based techniques, which lack the capability to provide real‐time, full‐field ...
Yagiz Yedekci   +2 more
wiley   +1 more source

Preclinical feasibility of EPID‐based transit dosimetry for total body irradiation

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 9, September 2026.
Abstract Background Conventional extended‐distance total body irradiation (TBI) is commonly verified using point dosimeters, which provide limited spatial information and require additional handling during a prolonged treatment procedure. A portable charge‐coupled device (CCD)‐based electronic portal imaging device (EPID) positioned downstream of the ...
Tetsu Nakaichi   +10 more
wiley   +1 more source

Automatic Night Lamp Using LDR

open access: yesInternational Journal of Engineering Research and Applications
This project focuses on designing a night lamp that automatically turns on in the absence of light and gets turned off in the presence of light using a light-dependent resistor (LDR). The LDR is a sensor whose resistance decreases with increasing light intensity, enabling it to detect ambient light levels.
Pillalamarri Madhavi   +5 more
openaire   +1 more source

Home - About - Disclaimer - Privacy