Onshore wind farms are usually connected to the power grid by 35 kV transmission lines. Due to the high altitude of the wind turbines and their associated long transmission corridors, lightning activities are more frequent for onshore wind farms compared
Chen Chen, Jiuguo Gao, Penghao Chu
doaj +1 more source
Pada jaringan distribusi tenaga listrik sering mengalami gangguan yang dapat menyebabkan kerugian , salah satu penyebab gangguan yang terjadi pada jaringan distribusi tenaga listrik adalah sambaran petir yang mengakibatkan tegangan lebih dan dapat ...
Dicky Satya Prawira +3 more
doaj +1 more source
Failure Risk Assessment of Surge Arrester Using Paralleled Spark Gap
Surge arresters are usually used to protect distribution feeders against randomly distributed lightning overvoltages. However, there is a probability of surge arrester failure due to an increase in its absorbed energy over the withstand capability.
Nehmdoh A. Sabiha +2 more
doaj +1 more source
Based on the operation situation of the lightning arresters commonly used in Shaanxi Province, a lightning arrester with multi-short-gaps is developed, which has excellent ability in extinguishing arc.
Zeli JU +6 more
doaj +1 more source
Design of MOA potential distribution and temperature distribution wireless acquisition system
The protection performance of lightning arrester(MOA) has direct impact on insulation level of the transformer and other electrical equipment , the potential distribution and the temperature distribution of the arrester determines the operating life of a
Li Jiaqi +5 more
doaj +1 more source
On the placement of line arrester on underbuilt overhead distribution line [PDF]
Lightning performance of distribution line is an important issue in the countries with high lightning density such as Malaysia. Many studies have been carried out to investigate the lightning performance and thus protect the overhead line from this ...
Ab Kadir, Mohd Zainal Abidin +2 more
core +1 more source
Application and Analysis for Surge Arrester on Lightning Protection of Distribution Network
In order to effectively reduce lightning stroke outage rate, effect of lightning protection with surge arrester on transmission line has been generally acknowledged relative to other lightning protection measures.
Wang Daxing +5 more
doaj +1 more source
The power system is affected by different levels of transient shock caused by different switching angle when AC filter switching on. The shock causes frequent action and aging of lightning arrester.
Xin Luo +3 more
doaj +1 more source
Tower grounding improvement versus line surge arresters: comparison of remedial measures for high-BFOR subtransmission lines [PDF]
This paper presents a technical/economic comparison between remedial measures aimed at improving the lightning performance of an existing Italian three-phase 150-kV overhead line.
GATTA, Fabio Massimo +4 more
core +1 more source
Application and Analysis for Surge Arrester on Lightning Protection of Distribution Network
In order to effectively reduce lightning stroke outage rate, effect of lightning protection with surge arrester on transmission line has been generally acknowledged relative to other lightning protection measures.
Wang Daxing +5 more
doaj +1 more source