Results 31 to 40 of about 1,613,220 (286)
Light Higgs bosons from a strongly interacting Higgs sector [PDF]
The mass and the decay width of a Higgs boson in the minimal standard model are evaluated by a variational method in the limit of strong self-coupling interaction.
+7 more
core +3 more sources
Quantum metrology exploits entangled states of particles to improve sensing precision beyond the limit achievable with uncorrelated particles. All previous methods required detection noise levels below this standard quantum limit to realize the benefits ...
Engelsen, N. J. +3 more
core +1 more source
Estimating the resolution limit of the map equation in community detection
A community detection algorithm is considered to have a resolution limit if the scale of the smallest modules that can be resolved depends on the size of the analyzed subnetwork.
Kawamoto, Tatsuro, Rosvall, Martin
core +2 more sources
Comparative analysis of Access PCT and Elecsys BRAHMS PCT assays for procalcitonin measurements [PDF]
Background Procalcitonin (PCT) is a crucial biomarker for diagnosing sepsis and managing antibiotic therapy. This study evaluated the analytical performance and comparability of the Access PCT and Elecsys BRAHMS PCT assays.
Hyunji Choi +2 more
doaj +1 more source
Accuracy of Expired BinaxNOW Rapid Antigen Tests
The widespread existence of expired antigen testing kits in households and potential coronavirus outbreaks necessitates evaluating the reliability of these expired kits.
Mary Jane E. Vaeth +13 more
doaj +1 more source
Numerical Optical Centroid Measurements
Optical imaging methods are typically restricted to a resolution of order of the probing light wavelength $\lambda_p$ by the Rayleigh diffraction limit. This limit can be circumvented by making use of multiphoton detection of correlated $N$-photon states,
Evers, Jörg, Gulfam, Qurrat-ul-Ain
core +1 more source
Calibration of a single atom detector for atomic micro chips [PDF]
We experimentally investigate a scheme for detecting single atoms magnetically trapped on an atom chip. The detector is based on the photoionization of atoms and the subsequent detection of the generated ions.
A. Günther +11 more
core +2 more sources
Tratamento de dados censurados em estudos ambientais
Due to the inherent limitations of the analytical methods of measurement, environmental exposure data often present observations described as below a certain detection limit, also called left-censored data. Censored data directly interferes in almost all
Cristiano Christofaro +1 more
doaj +1 more source
ORT observations of the damped Lyman alpha system towards PKS 0201+113
We report a deep radio search with the Ooty Radio Telescope (ORT) for the redshifted 21 cm absorption line from the damped Lyman alpha system seen at redshift 3.388 against the quasar PKS 0201+113.
Chengalur, Jayaram N, Kanekar, Nissim
core +1 more source
TEM10 homodyne detection as an optimal small displacement and tilt measurements scheme [PDF]
We report an experimental demonstration of optimal measurements of small displacement and tilt of a Gaussian beam - two conjugate variables - involving a homodyne detection with a TEM10 local oscillator.
Bachor, Hans A. +6 more
core +3 more sources