Results 61 to 70 of about 742,295 (257)

Forward‐Biased Perovskite Photodiodes for In‐Sensor Optical Change Sensing

open access: yesAdvanced Functional Materials, EarlyView.
A forward‐biased perovskite photodiode is introduced as an in‐sensor analog preprocessing unit that uses current balancing between photocurrent and injection current to generate optical changes relative to programmable optical reference levels. The device directly converts reference‐relative optical changes into bipolar current signals, enabling sensor‐
Eungseon Yeon   +14 more
wiley   +1 more source

Mechanical Evaluation Of Locking Compression Plate [PDF]

open access: yes, 2018
Locking Compression Plate, LCP has been widely used in the femoral shaft fracture fixation. The clinical cases show that the failure of locking compression plate is possible before the adequate healing of the fracture.
Tong, Wen Le
core   +1 more source

Modern anatomical locking plates are associated with increased postoperative wound complications and unplanned surgical revisions compared to standard tubular plates in the management of unstable ankle fractures: a comparative cohort study in 595 patients

open access: yesPatient Safety in Surgery
Background The clinical benefit of locking plates in distal fibula fractures has not yet been proven. In addition, the risk of wound complications appears to be higher than with conventional tubular plates.
Patrick Gahr   +4 more
doaj   +1 more source

3D‐Printed Gradient Shape‐Memory Strain Sensors With Rewritable Gauge Factors

open access: yesAdvanced Functional Materials, EarlyView.
A 3D‐printed shape‐memory strain sensor combines thermomechanical programming with gradient architectural design. Preset strain rewrites the gauge factor (GF), while the gradient geometry amplifies the response through strain redistribution. Reprogrammable sensitivity enables the same sensor to detect weak pulse signals and monitor large‐amplitude ...
Xuan Zhang   +10 more
wiley   +1 more source

Biomechanical evaluation of acromion and scapular spine fracture repair techniques systematic review

open access: yesJSES Reviews, Reports, and Techniques
Background: The incidence of reverse total shoulder arthroplasty (rTSA) is rising. Acromion and scapular spine fractures (ASFs) are a known complication following rTSA with an incidence rate of around 5%.
John W. Moore, BS   +5 more
doaj   +1 more source

A New Bioactive Glass‐Based Hybrid Bioink With Enhanced Cell Viability and Antibacterial Properties

open access: yesAdvanced Healthcare Materials, EarlyView.
Graphical illustration of the production and characterization process, demonstrating the multiple functions of the new hybrid gelatin methacryloyl‐silver‐bioactive glass (GAB) material. Created in https://BioRender.com. ABSTRACT Recent advances in three‐dimensional bioprinting (3DBP) technology enable the production of customized bone substitutes ...
Adam C. Marsh   +14 more
wiley   +1 more source

A biomechanical study of headless compression screws versus a locking plate in radial head fracture fixation

open access: yes, 2019
Hypothesis: Fixation of a 3-part radial head fracture with cannulated compression screws will show equivalent stiffness to a locking plate under axial load. Debate exists regarding the management of Mason type III fractures, with many believing that open
Rebgetz, PR   +4 more
core   +1 more source

Targeting CD300a Signaling With a Phosphatidylserine‐Presenting Hydrogel Rescues Macrophage Dysfunction and Accelerates Diabetic Wound Healing

open access: yesAdvanced Healthcare Materials, EarlyView.
Schematic illustration of the proposed mechanism: PEG/RGD‐PSLs mimic apoptotic cells to engage PS receptors (notably CD300a), transducing an inhibitory signal that suppresses the MyD88/NF‐κB pathway, leading to global anti‐inflammatory and pro‐reparative effects.
Lele Wu   +10 more
wiley   +1 more source

Development of a Titanium Plate for Mandibular Angle Fractures with a Bone Defect in the Lower Border: Finite Element Analysis and Mechanical Test

open access: yeseJournal of Oral Maxillofacial Research, 2015
Objectives: The aim of the present study was to develop a plate to treat mandibular angle fractures using the finite element method and mechanical testing.
Douglas Rangel Goulart   +3 more
doaj   +1 more source

Biomechanical evaluation of different angle-stable locking plate systems for mandibular surgery [PDF]

open access: yes, 2015
PURPOSE To compare the initial stability and stability after fatigue of three different locking systems (Synthes(®), Stryker(®) and Medartis(®)) for mandibular fixation and reconstruction.
Bürki, Alexander   +3 more
core   +1 more source

Home - About - Disclaimer - Privacy