Results 71 to 80 of about 742,295 (257)
Optical Detection of Cellular Signals at Material Interfaces
Emerging functional materials are transforming optical detection of cellular signals. This review highlights optical techniques that exploit the unique optical properties of diverse materials to detect and quantify cellular electrical, chemical, and mechanical signals, and discusses key opportunities and challenges.
Xuchen Ren +5 more
wiley +1 more source
Complication with Removal of a Lumbar Spinal Locking Plate [PDF]
Introduction. The use of locking plate technology for anterior lumbar spinal fusion has increased stability of the vertebral fusion mass over traditional nonconstrained screw and plate systems.
Christopher Lenarz +3 more
core +1 more source
Three‐dimensional bioprinting transforms breast cancer modeling from simple constructs into spatially organized, multicellular, perfused, and patient‐derived platforms. This review shows how bioinks, cellular composition, architecture, and flow govern tumor behavior and drug response, while revealing why complexity alone is insufficient without ...
Mustafa Nakipoglu +7 more
wiley +1 more source
Mechanical Failure of the Distal Radius Volar Locking Plate
Purpose. To review 9 cases of mechanical failure of the volar locking plate for distal radial fractures. Methods. Records of 374 consecutive patients who underwent volar locking plating for distal radial fractures were reviewed.
Tun-Lin Foo +3 more
doaj +1 more source
Objectives: This study was designed to compare the results of palmar locking plate and K-wire augmented external fixation in the treatment of intra-articular comminuted distal radius fractures.
Arel Gereli +3 more
doaj +1 more source
Lignin‐mimicking protein methylation can enhance the efficacy and mitigate the toxicity of the classic FOLFOX chemotherapy regimen. ABSTRACT FOLFOX has served as the standard chemotherapy regimen for advanced stages, specifically in the treatment of pancreatic, colorectal, and bladder cancers.
Shiyao Song +14 more
wiley +1 more source
Polyaxial versus Uniaxial Volar Locking Plate for Distal Radial Fractures
Purpose. To compare the penetration of the distal screws in relation to the thickness of the distal metaphysis in the polyaxial versus uniaxial volar locking plates. Methods.
Louay Al-Mouazzen +3 more
doaj +1 more source
Removal of locking plates: new implant, new challenges and new solutions
Removal of locking plates in many ways poses novel challenges compared to conventional plates. None of the techniques described for the removal of locking plates are adequate for all situations.
Bhavuk Garg +4 more
doaj +1 more source
Measuring the Hall Effect in Hysteretic Materials
The authors highlight common pitfalls in measuring the Hall effect: in hysteretic magnets, improper data processing can create signals that look exotic but are not real. This Perspective explains the origin of these artifacts and presents practical measurement strategies that help researchers identify reliable Hall responses in complex magnetic ...
Jaime M. Moya +6 more
wiley +1 more source
Lengths, type (locking/non-locking), and position of screws used for each plate.
Lengths, type (locking/non-locking), and position of screws used for each plate.
Vincenzo Giordano (5669897) +7 more
core +1 more source

