Results 101 to 110 of about 959,494 (252)

Locking plate fixation of humeral head fractures with a telescoping screw : a comparative biomechanical study versus a standard plate

open access: yes, 2012
Objectives: Locking plate fixation of humeral head fractures bares the risk of glenohumeral screw penetration. In order to circumvent this problem it is recommended to insert shorter locking screws having at least a 6 mm distance to the humeral head ...
Mittlmeier, Thomas   +6 more
core   +1 more source

Impact of augmentation strategy variations on the mechanical characteristics of patients with osteoporotic proximal humerus fractures with medial column instability

open access: yesFrontiers in Bioengineering and Biotechnology
IntroductionLow bone density and lack of medial support are the two most important factors affecting the stability of locking plate fixation for osteoporotic proximal humeral fractures (PHFs). This study aimed to compare the biomechanical characteristics
Guoqing Xiao   +5 more
doaj   +1 more source

Locking plate fixation compared with tension-band wiring for patellar fractures: a multicentre randomized controlled trial

open access: yes
Aims Patellar fractures are associated with considerable postoperative morbidity, and tension-band wiring has high complication rates and suboptimal outcomes. Locking plate fixation is a recent surgical innovation
Rikke Thorninger   +9 more
core   +1 more source

Cross‐scale Material‐Structure Synergy for 2D Metamaterials: Toward Customizable Intelligent Electromagnetic Manipulation in Multiphysics Fields

open access: yesAdvanced Science, EarlyView.
Recent advances in metasurface‐enabled low‐observable technologies are reviewed from the perspective of cross‐scale material–structure synergy. Electromagnetic, thermal, optical, and acoustic stealth are highlighted together with dynamic tuning, programmable coding, data‐driven inverse design, artificial intelligence, multispectral compatibility, and ...
Shuhao Wang   +5 more
wiley   +1 more source

Plant Metabolites Screening Identifies 7‐epi‐10‐Deacetyltaxol Inhibiting Cell Division by Interfering With the Cell Cycle and Microtubule Organization

open access: yesAdvanced Science, EarlyView.
In this study, an efficient screening system is developed for plant metabolites to find a compound, 7‐epi‐10‐deacetyltaxol, inhibits tissue elongation. It suppresses plant growth through brassinosteroid and microtubule pathways. It is later applied to animal cells and human tumor organoids, resulting in similar cell division suppression. These findings
Yan‐Jie Zhang   +20 more
wiley   +1 more source

Outcomes of plated metatarsophalangeal joint fusions without transarticular screw fixation

open access: yesJournal of the Foot & Ankle
Objective: Evaluate the outcomes of metatarsophalangeal (MTP) arthrodesis performed with plate-only fixation. Methods: A retrospective observational study was conducted on 68 patients submitted to MTP arthrodesis with plate fixation between June 2021 ...
Parimal Rana   +7 more
doaj   +1 more source

Engineered Allosteric Biosensor for In Situ DNA Glycosylase Detection in Neuroblastoma Risk Stratification and Drug Resistance Monitoring

open access: yesAdvanced Science, EarlyView.
An engineered allosteric biosensor (UUU‐DZ‐tFNA) was developed, in which UDG specifically recognizes and activates a DNAzyme to achieve signal cycle amplification in a sequentially activatable mode. UUU‐DZ‐tFNA achieves in situ UDG detection across multiple biological levels and facilitates risk stratification and drug resistance monitoring of NB ...
Yaqing Lu   +10 more
wiley   +1 more source

Vine‐Inspired Soft Robotics: Materials, Actuations, and Emerging Applications

open access: yesAdvanced Science, EarlyView.
Vine‐inspired robots grow from the tip, enabling navigation through confined spaces with minimal disturbance. This Review summarizes material and actuation strategies for vine‐inspired growth, key functions including steering, retraction, attachment, branching, and variable stiffness, and emerging applications spanning medical intervention, confined ...
Jiahao Wu   +7 more
wiley   +1 more source

Comparison of clinical application of locking plate versus cancellous screw in structural autologous bone grafting during TKA for medial tibial bone defects

open access: yesFrontiers in Bioengineering and Biotechnology
ObjectiveTo compare the clinical outcomes of locking plate versus cancellous screw fixation in structural autologous bone grafting for medial tibial bone defects during total knee arthroplasty.MethodsA retrospective analysis was conducted on 66 patients ...
Nanshan Ma   +18 more
doaj   +1 more source

Engineering Spatially Localized Bioactive Microenvironments in Assembly Implants for Spatially Extended Bone Ingrowth

open access: yesAdvanced Science, EarlyView.
An assembly porous titanium/β‐TCP implant is developed to establish a spatially programmable osteogenic microenvironment for enhanced osseointegration. By decoupling mechanical support from bioactive ion release, localized ionic gradients generated from the β‐TCP module direct osteogenic activity and bone ingrowth toward the porous titanium framework ...
Heng Zhang   +5 more
wiley   +1 more source