Results 21 to 30 of about 104,849 (208)
Near‐Infrared Light‐Driven Zn/Au Janus Micromotors for Multiplex SERS Detection of Anticancer Drugs
Zn/Au Janus micromotors, propelled by thermophoretic effects under NIR light, function as active SERS platforms for single and multiplex detection of anticancer drugs. Their dynamic motion enhances analyte exchange at the Au interface, reducing saturation and competitive adsorption, thereby improving sensitivity and extending the linear detection range.
Tijana Maric +8 more
wiley +1 more source
Blood Biomarkers and Surface‐Enhanced Raman Spectroscopy for Gout: A Comprehensive Review
Schematic illustrating gout disease progression from asymptomatic hyperuricemia to chronic tophaceous disease, highlighting the limitations of conventional imaging and biochemical diagnostics and the potential of engineered SERS platforms for ultrasensitive blood‐based detection of urate‐related biomarkers across disease stages, with the color gradient
Isuri Perera +6 more
wiley +1 more source
This study relies on the development of a new sensor that can detect two closely related proteins involved in Alzheimer's disease at the same time. Unlike traditional methods, it works in natural conditions and does not require sample pretreatment. The device is highly sensitive and was successfully tested on patient samples, offering promises for ...
Giulia Siciliano +12 more
wiley +1 more source
A 3D‐printed piezoionic GPMx hydrogel enables stable electromechanical signal generation under mechanical loading, exhibiting long‐term durability and low fatigue. As a bioactive patch, it restores endogenous bioelectricity to stimulate osteogenesis via Ca2+ influx and mitochondrial activation, while simultaneously enabling label‐free alkaline ...
Sayan Deb Dutta +3 more
wiley +1 more source
Electrically Readable Lateral Flow Assay Using Organic Transistors for Diagnostic Applications
Electrolyte‐gated organic field‐effect transistors (EGOFETs) are integrated with lateral flow (LF) paper fluidics to create a reusable, portable, and low‐cost point‐of‐care (PoC) diagnostic test. The devices are validated for Human Immunoglobulin G detection, achieving high sensitivity (0.1 fm), selectivity, and reproducibility with rapid results in 20–
María Jesús Ortiz‐Aguayo +4 more
wiley +1 more source
2D MOF with Intrinsic Porosity for Colorimetric Volatile Organic Compounds (VOCs) Detection
An uncommon 2D MOF with intrinsic in‐plane porosity that can be mechanically exfoliated undergoes a distinct and reversible colour change upon exposure to various volatile organic compounds. ABSTRACT In this work, we report an uncommon 2D metal–organic framework (MOF) with intrinsic in‐plane porosity that undergoes a distinct and reversible colour ...
Sergio R. Gamarra +4 more
wiley +1 more source
A thermally adaptive plasmonic metasurface, functionalized with poly(N‐isopropylacrylamide) (PNIPAM) and anti‐CD63 antibodies, enables precise, on‐demand capture and release of extracellular vesicles (EVs). Delivering high recovery, improved purity, and intact vesicle structure, the platform offers a versatile, label‐free solution for real‐time EV ...
Beyza Nur Kucuk +7 more
wiley +1 more source
High‐Sensitivity Terahertz Gas Sensing Enabled by Undercut Metal‐Dielectric‐Metal Metamaterial
A terahertz (THz) metamaterial gas sensor is demonstrated using a metal–dielectric–metal (MDM) absorber with an undercut dielectric layer, which enlarges the gas‐replaced volume and strengthens refractive‐index perturbation of the resonant mode. A reflection dip at 0.766 THz is observed, and acetone–nitrogen tests yield concentration‐dependent shifts ...
Naoki Inomata +2 more
wiley +1 more source
Layered Nanoporous Platforms for SERS Sensing
Here, we present a detailed investigation of the SERS performance of layered nanoporous metals. The controlled deposition of well‐defined, stacked porous layers enabled a systematic analysis of the effects of multimetallic systems in SERS experiments. Numerical models are also used to support the experimental findings.
Yanqiu Zou +18 more
wiley +1 more source
An Advanced Molecularly Imprinted Polymer‐Based Electrochemical Aptasensor for Carbendazim Detection
A dual‐recognition electrochemical aptasensor that integrates a molecular imprinted polymer (MIP) and an aptamer is developed for the detection of a common pesticide, carbendazim (CBZ). The resulting sensor exhibits enhanced selectivity toward CBZ over structurally similar compounds and achieves a low detection limit of 1.3 nm, demonstrating its ...
Suthira Pushparajah +3 more
wiley +1 more source

