Results 131 to 140 of about 130,892 (321)
Analysis of seven pesticides in sediments was successfully achieved using comprehensive two-dimensional gas chromatography with micro-electron capture detection, as it provided higher sensitivity and less matrix interference.
Juliana Macedo da Silva +2 more
doaj +1 more source
Reporting the limits of detection and quantification for environmental DNA assays
Background Environmental DNA (eDNA) analysis is increasingly being used to detect the presence and relative abundance of rare species, especially invasive or imperiled aquatic species. The rapid progress in the eDNA field has resulted in numerous studies
Katy E. Klymus +13 more
doaj +1 more source
Validated UPLC-MS/MS methods to quantitate free and conjugated Alternaria toxins in commercially available tomato products and fruit and vegetable juices in Belgium [PDF]
Ultraperformance liquid chromatography tandem mass spectrometry and Quick, Easy, Cheap, Effective, Rugged, and Safe based analytical methodologies to quantitate both free (alternariol (1), alternariol monomethyl ether (2), tenuazonic acid (3), tentoxin ...
Asam, Stefan +10 more
core +3 more sources
Machine Learning–Enhanced Fluorescence Cryptography with NADH‐Responsive Polymer Dots
This study presents a smart anticounterfeiting system using semiconducting polymer dots (Pdots) that exhibit tunable fluorescence responses to NADH. By integrating these dynamic optical signals with machine learning–based decoding, the work establishes a secure and intelligent encryption platform, showing a novel strategy that links chemical sensing ...
Zhengkun Zhan +7 more
wiley +1 more source
Five sustainable and validated UV spectrophotometric methods were developed for analyzing chloramphenicol (CHL) and dexamethasone sodium phosphate (DSP) in pure and ophthalmic dosage forms. CHL was detected by zero order spectra method at 292.0 nm in the
Heidi R. Abd El-Hadi
doaj +1 more source
Derivative spectrophotometric method for determination of acyclovir in polymeric nanoparticles
A derivative spectrophotometric method was validated for quantification of acyclovir in poly (n-butylcyanoacrylate) (PBCA) nanoparticles. Specificity, linearity, precision, accuracy, recovery, detection (LOD) and quantification (LOQ) limits were ...
Guilherme Diniz Tavares +6 more
doaj +1 more source
Stir Bar Sorptive Extraction of Volatile Compounds in Vinegar: Validation Study and Comparison With Solid Phase Microextraction [PDF]
Stir bar sorptive extraction was evaluated for analysing volatiles in vinegar. The procedure developed shows detection and quantitation limits, and linear ranges adequate for analysing this type of compounds. The accuracy obtained was close to 100%, with
Alves +25 more
core +2 more sources
ABSTRACT This study describes the use of microchip micellar electrokinetic chromatography (MEKC) integrated with capacitively coupled contactless conductivity detection (C4D) for the determination of monoethylene glycol (MEG) in gas condensate samples.
Maurício M. L. Pereira +6 more
wiley +1 more source
Corrigendum: Detection of Aflatoxins in Different Matrices and Food-Chain Positions
Gabriella Miklós +9 more
doaj +1 more source
This paper describes selective molecularly imprinted solid-phase extraction of ttMA from urine samples followed by derivatization and analysis by gas chromatography/mass spectrometry (GC/MS). The analytical calibration curve ranged from 0.3 to 7.0 mg L-1
Lidiane Silva Franqui +3 more
doaj +1 more source

