Results 21 to 30 of about 1,457,064 (320)

Measurement of Untruncated Nuclear Spin Interactions via Zero- to Ultra-Low-Field Nuclear Magnetic Resonance [PDF]

open access: yes, 2015
Zero- to ultra-low-field nuclear magnetic resonance (ZULF NMR) provides a new regime for the measurement of nuclear spin-spin interactions free from effects of large magnetic fields, such as truncation of terms that do not commute with the Zeeman ...
Bajaj, Vikram S.   +7 more
core   +1 more source

Selective drug trace detection with low-field NMR [PDF]

open access: yesThe Analyst, 2011
Advances with para-hydrogen induced polarization open up new fields of applications for portable low-field NMR. Here we report the possibility of tracing drugs down to the micromolar regime. We could selectively polarize nicotine quantities similar to those found in one cigarette. Also less than 1 mg of harmine, a drug used for treatment of Parkinson's
Glöggler, S.   +5 more
openaire   +4 more sources

Solid-state NMR signals at zero-to-ultra-low-field

open access: yesJournal of Magnetic Resonance Open, 2022
Zero-to-ultra-low-field nuclear magnetic resonance (ZULF NMR) is fast emerging as a viable spectroscopic approach to study samples under conditions dominated by internal spin interactions.
K.K. George Kurian   +2 more
doaj   +1 more source

Use of low-field NMR for the characterization of gels and biological tissues

open access: yesADMET and DMPK, 2018
The focus of this paper is on the theoretical interpretation of Low Field Nuclear Magnetic Resonance (LF-NMR) data regarding hydrogels architecture and on the most interesting applications of LF-NMR presented by this research group at the 6th IAPC ...
Michela Abrami   +5 more
doaj   +1 more source

Steady-State Free Precession sequences for high and low field NMR spectroscopy in solution: Challenges and opportunities

open access: yesJournal of Magnetic Resonance Open, 2023
The receptivity of NMR spectroscopy is low when compared to other techniques. Historically, increasing the strength of the static magnetic field has been the major approach to increase NMR sensitivity.
Tiago Bueno Moraes   +5 more
doaj   +1 more source

Inline NMR via a Dedicated V-Shaped Sensor

open access: yesSensors, 2023
Process monitoring and control require dedicated and reliable measures which reflect the status of the process under investigation. Although nuclear magnetic resonance is known to be a versatile analytical technique, it is only seldomly found in process ...
Eric Schmid   +4 more
doaj   +1 more source

Guar gum/borax hydrogel: Rheological, low field NMR and release characterizations

open access: yeseXPRESS Polymer Letters, 2013
Guar gum (GG) and Guar gum/borax (GGb) hydrogels are studied by means of rheology, Low Field Nuclear Magnetic Resonance (LF NMR) and model drug release tests. These three approaches are used to estimate the mesh size (ζ) of the polymeric network.
M. Grassi   +8 more
doaj   +1 more source

On-Site Measurement of Fat and Protein Contents in Milk Using Mobile NMR Technology

open access: yesMolecules, 2022
Robust and easy-to-use NMR sensor technology is proposed for accurate, on-site determination of fat and protein contents in milk. The two parameters are determined using fast consecutive 1H and 35Cl low-field NMR experiments on milk samples upon the 1:1 ...
Morten K. Sørensen   +4 more
doaj   +1 more source

Digital filters for low‐field NMR

open access: yesConcepts in Magnetic Resonance Part B: Magnetic Resonance Engineering, 2016
AbstractWe review the theory and operation of digital filters in modern nuclear magnetic resonance (NMR) spectrometers with fully digital receivers. Custom digital filters tailored for particular experimental requirements offer substantial improvements in signal‐to‐noise ratio (SNR), sensitivity, pulse sequence timing, and rejection of heteronuclear ...
Andrea Valori   +2 more
openaire   +1 more source

Wavelet Transform-Based Signal Denoising in Low-Field NMR

open access: yesChinese Journal of Magnetic Resonance, 2018
Low-field NMR often uses permanent magnet. The signals obtained contain high level of white Gaussian noises, and have low signal-to-noise ratio (SNR). In recent years, many denoising methods have been proposed for low-field NMR measurements.
CHANG Xiao, SU Guan-qun, NIE Sheng-dong
doaj   +1 more source