Results 251 to 260 of about 9,430,970 (287)
Some of the next articles are maybe not open access.

Low Voltage Battery Cable

<div class="section abstract"> <div class="htmlview paragraph">This SAE Standard covers low voltage battery cable intended for use at a nominal system voltage of 60 VDC (25 VAC) or less in surface vehicle electrical systems. The tests are intended to qualify cables for normal applications with limited exposure to fluids and physical abuse.
openaire   +1 more source

Application of voltage response measurement on low voltage cables

2009 IEEE Electrical Insulation Conference, 2009
The application of voltage response measurement is a very effective tool to determine of the aging state of oil-paper insulated cables. The initial slope of the decay voltage is directly proportional to the conductivity of the insulation and the initial slope of the return voltage is proportional to the intensity of polarization processes.
Z. A. Tamus, I. Berta
openaire   +1 more source

Low Voltage Primary Cable

<div class="section abstract"> <div class="htmlview paragraph">This SAE Standard covers low voltage primary cable intended for use at a nominal system voltage of 60 VDC (25 VAC) or less in surface vehicle electrical systems. The tests are intended to qualify cables for normal applications with limited exposure to fluids and physical abuse.
openaire   +1 more source

Intermittent Arcing Fault on Underground Low-Voltage Cables

IEEE Transactions on Power Delivery, 2004
Arcing faults on 600/347-V underground cables can cause considerable damage, even explosions, despite the installed protection system. In fact, the protection sometimes appears to be quite slow to operate considering the prospective short circuit. Laboratory tests provided an opportunity to better characterize these arcing faults and prove that they ...
A. Hamel, A. Gaudreau, M. Cote
openaire   +1 more source

Low Voltage Ultra-Thin Wall Primary Cable

2023
<div class="section abstract"> <div class="htmlview paragraph">This standard covers ultra-thin wall low voltage primary cable intended for use at a nominal system voltage of 60 VDC (60 VAC rms) or less in surface vehicle electrical systems.
openaire   +1 more source

Cable ampacity practice for low voltage and medium voltage power cables

IEEE 1988 Annual Textile Industry Technical Conference, 2003
The 1987 National Electrical Code (NEC) permits the use of additional ampacity tables covering various installation situations. These tables cover low-voltage installations rated 0 to 2000 V and medium-voltage installations for cables rated 2001 to 35000 V.
openaire   +1 more source

Low-Voltage Ultrathin Wall Primary Cable

2017
<div class="section abstract"> <div class="htmlview paragraph">This SAE Standard covers low-voltage, ultrathin wall, primary cable intended for use at a nominal system voltage of 60 V DC or less in surface vehicle electrical systems. The tests are intended to qualify cables for normal applications with limited exposure to fluids and ...
openaire   +2 more sources

Conductive-rubber shielded low-voltage cables - An update

IEEE Transactions on Industry Applications, 1987
Recent efforts to fabricate and test a conductive-rubber shielded cable for shuttle-car applications has shown progress, especially in regards to lower-volume-resistivity shield materials. Earlier work had indicated a need for volume resistivities on the order of 100 Ω.cm or less.
James N. Tomlinson, Lloyd A. Morley
openaire   +1 more source

Irregular Low-Voltage Electrical Cables

2023 IEEE IAS Electrical Safety Workshop (ESW), 2023
Danilo Ferreira De Souza   +2 more
openaire   +1 more source

Cabling Requirements for Low-Voltage DC Systems

2023 IEEE Fifth International Conference on DC Microgrids (ICDCM), 2023
George Govaerts   +3 more
openaire   +1 more source

Home - About - Disclaimer - Privacy