Nowadays stochastic occurrence of main grid disturbances (LVRT, FRT) leads to high level vibrational excitation of the drive train during operation of wind turbines. Regardless of the drivetrain design as a direct, hybrid or multi-stage geared one in this case high mechanical and electrical stresses should be ...
null Dr.-Ing. Jan Wenske +1 more
openaire +1 more source
If the linear node voltage equation set obtained from the faulty composite sequential network is solved directly by linear transformation, it is not possible to accurately calculate and obtain the fault current and the voltage at the merging point of IIDG.
Zhuoran Song +5 more
wiley +1 more source
Voltage sags often disrupt the normal functioning of sensitive equipment and distributed generators (DGs), making voltage sag mitigation based on corresponding assessments crucial. Voltage sag characteristics, including voltage magnitude and sag duration,
Xian-yong Xiao +3 more
doaj +1 more source
Power Control Flexibilities for Grid-Connected Multi-Functional Photovoltaic Inverters [PDF]
This study explores the integration issues of next-generation high-penetration photovoltaic (PV) systems, where the grid is becoming more decentralised and vulnerable.
Blaabjerg, Frede +3 more
core +2 more sources
1. Presenting a phasor estimation model for 72‐pulse converters of UIPC device based on artificial neural networks. 2. Using the data of a single terminal to estimate for various types of short circuits on both sides of UIPC. 3. No need for a predetermined threshold value to detect the fault side around UIPC. 4.
Babak Bahadori +2 more
wiley +1 more source
Study on Low Voltage Ride Through for Direct-drive VSCF Wind Power System
New grid regulation brings forward the requirements on wind turbines for having Low Voltage Ride Through(LVRT)capability and supplying reactive power compensation to the grid during voltage sag prcoess.
张宪平
doaj
Low-voltage ride-through control strategy for permanent magnet synchronous generator under weak grid
In order to improve the low-voltage ride-through(LVRT)capability of permanent magnet synchronous generator(PMSG)under weak grid, this paper proposes a low-voltage ride-through control strategy for power support and auxiliary protection of unloading ...
CHEN Zhong, DING Linzhi, GU Chunsong
doaj +1 more source
Minimising the impact of disturbances in future highly-distributed power systems [PDF]
It is expected that future power systems will require radical distributed control approaches to accommodate the significant expansion of renewable energy sources and other flexible grid devices.
Belloni, F.R. +11 more
core +1 more source
Since the stator of DFIG-based wind turbines is directly connected to the grid, it is dramatically affected by transient situations that may occur on the grid side. In order to meet grid code requirements, reactive power support must be provided to keep the DFIG connected to the grid during the transient state. To achieve this, Low Voltage Ride Through
M. Kenan Döşoğlu, Muhsin Uğur Doğan
openaire +2 more sources
Water diversion system of the variable speed pumped storage unit with full‐size converter. ABSTRACT This paper aims to study the frequency‐power coupling dynamic response and regulation characteristics of a variable speed pumped storage unit (VSPSU) with full‐size converter (FSC).
Yanhao Li, Kedong Shu, Wencheng Guo
wiley +1 more source