Results 61 to 70 of about 1,240 (203)
Sequence extraction-based low voltage ride-through control of grid-connected renewable energy systems [PDF]
Various faults can cause voltage sag in the power grid at different voltage levels across the network. Balanced or unbalanced voltage sags lead to grid instability by tripping off a large number of wind or solar power plants from the electric power ...
Achour, Y. +17 more
core +1 more source
Preventive Control Considering Stability Constraints for Repeated Low Voltage Ride Through Events
This paper proposes a voltage stability preventive control strategy that accounts for repeated low‐voltage ride‐through characteristics. The method first partitions the system and constructs a short‐term voltage stability assessment index that effectively incorporates repetitive LVRT events, while offline generating a corresponding set of anticipated ...
Zhichong Cao +5 more
wiley +1 more source
Analysis of Low Voltage Ride Through Techniques for Grid-Connected Photovoltaic Systems
This paper presents a comparative analysis of different low voltage ride though strategies proposed for operation of a grid connected two stage photovoltaic system under low voltages.
V, Seshadri Sravan Kumar, Naresh, P.
core +1 more source
Enhanced critic‐only DQN with smoothing enables continuous SVC control for damping inter‐area oscillations. The state selection via participation and residue analysis captures critical key modes. Orthogonal array efficiently tunes hyperparameters with low cost.
Gunawan Dewantoro +3 more
wiley +1 more source
Low-voltage ride-through capability improvement of Type-3 wind turbine through active disturbance rejection feedback control-based dynamic voltage restorer [PDF]
Disconnections due to voltage drops in the grid cannot be permitted if wind turbines (WTs) contribute significantly to electricity production, as this increases the risk of production loss and destabilizes the grid.
Abdelmounime El Magri +11 more
core +1 more source
In practical engineering, large-scale wind power integration typically requires long-distance transmission lines to deliver power to load centers. The resulting weak sending-end systems lack support from synchronous power sources.
Yunpeng Wang +5 more
doaj +1 more source
This paper analyses the distribution of fault current samples for both external and internal faults conditions and quantifies the differences in the features by using the third‐order cumulant and kurtosis. On this basis, a pilot protection scheme was proposed for transmission lines wind farm transmission line connected to VSC station.
Ziliang Wu +7 more
wiley +1 more source
Addressing Distance Relay Mal‐Operation in Low‐Inertia Grids: A PLL‐Informed Power Swing Assessment
A key advantage of the proposed approach is its independence from PLL control settings, relying solely on locally measured electrical quantities, which ensures robust, fast, and practical implementation in existing commercial distance relays. ABSTRACT The increasing penetration of inverter‐based resources (IBRs) has substantially reduced system inertia
Ahmad Reza Baghaei +2 more
wiley +1 more source
Voltage Sag Detection in Grid-Connected Photovoltaic Power Plant for Low Voltage Ride-Through Control [PDF]
Background: Due to the high level of photovoltaic power plants (PVPPs) penetration into power grids, disconnections of these plants during faults are no longer possible as it may cause problems concerning stability, quality, and operation of the power ...
Muhamad Zahim, Sujod, Al-Shetwi, Ali Q.
core +1 more source
Wind farms must be linked to the grid during the voltage sag. Therefore, the improvement of low-voltage ride-through (LVRT) capability of wind turbine (WT) is a vitally issue. Protection system based on an interval type-2 fuzzy logic system (IT-2 FLC) is
Altan Gencer
doaj +1 more source