Results 51 to 60 of about 22,749,812 (200)
Under identical conditions, we benchmark PID against Fuzzy‐Logic control for a single‐phase H‐bridge inverter. FLC achieves faster rise/settling with lower THD and better disturbance rejection than tuned PID while requiring explicit rule design—offering a reproducible baseline and deployment guidance for power‐quality‐constrained inverter applications.
Baraa Taha +4 more
wiley +1 more source
Enhancing LVRT Capability of DFIG-Based Wind Turbine Systems with SMES Series in the Rotor Side
The necessary Low Voltage Ride Through (LVRT) capability is very important to wind turbines. This paper presents a method to enhance LVRT capability of doubly fed induction generators- (DFIGs-) based wind turbine systems with series superconducting ...
Xiao Zhou, Yuejin Tang, Jing Shi
doaj +1 more source
Decentralized energy systems are gaining momentum, and microgrids have become a vital component of the modern power landscape. Yet, maintaining power quality within these systems presents ongoing challenges due to the presence of nonlinear loads, variable renewable energy sources, and frequent switching operations.
Mahnoor Zahid +5 more
wiley +1 more source
Voltage dip generator for testing wind turbines connected to electrical networks [PDF]
This paper describes a new voltage dip generator that allows the shape of the time profile of the voltage generated to be configured. The use of this device as a tool to test the fault ride-through capability of wind turbines connected to the electricity
N. Herrero +28 more
core +1 more source
This study establishes a hybrid microgrid model integrating a Doubly Fed Induction Generator (DFIG), a photovoltaic (PV) array, and a battery energy storage system, and proposes a coordinated control framework. The DFIG regulates DC‐bus voltage through the grid‐side converter and performs maximum power tracking via the rotor‐side converter, while the ...
Chunyan Li +4 more
wiley +1 more source
Improving Low Voltage Ride-through Capabilities for Grid Connected Wind Turbine Generator [PDF]
Low Voltage Ride-Through (LVRT) is one of the most dominant grid connection requirements to be met by Wind Energy Conversion Systems (WECS). In presence of grid voltage dips, a mismatch is produced between the generated active power and the active power ...
Tank, Ishwari +2 more
core +1 more source
Aiming at the modeling problem of bipolar distributed photovoltaic (DPV) cluster, this paper proposes a clustering equivalent modeling method based on clustering algorithm. First, by analyzing the detailed model of bipolar DPV, it is found that the indexes that can reflect its steady‐state and dynamic characteristics mainly include energy storage ...
Tianyu Zhang, Hassan Haes Alhelou
wiley +1 more source
Low-voltage ride-through (LVRT) is one of the most important criteria for integrating wind energy into the power grid. Based on grid connection codes, wind generators must remain connected during fault conditions.
Mahyar Gholizadeh +5 more
doaj +1 more source
Enhancing LVRT Capability of DFIG-Based Wind Turbine Systems with SMES and STATCOM
Nowadays, renewable energy technologies such as a wind turbine have experienced a rapid growth in the world. Doubly Fed Induction Generators (DFIGs) are extensively used in variable speed wind power plants due to their advantages that include reduced ...
Mahmoud Khamaira +2 more
doaj
ABSTRACT This paper presents a comprehensive review of recent global research on voltage control in distribution systems with high penetration of distributed generation. First, it examines voltage regulation challenges in distribution systems that integrate distributed generation.
Htutzaw Hein +6 more
wiley +1 more source