Results 51 to 60 of about 513 (169)

Research on Low Voltage Ride Through for Small Direct-driven Permanent Magnet Wind Turbine in Low Voltage Microgrid

open access: yes发电技术, 2020
Aiming at the problem of low voltage ride through (LVRT) of the generation side uncontrollable rectifying permanent magnet wind turbine in the low voltage microgrid, the operating characteristics of the permanent magnet synchronous generator (PMSG) wind ...
Haichuan ZHAO   +3 more
doaj   +1 more source

Higher‐Order Statistics Based Pilot Protection Scheme for Wind Farm Transmission Line Connected to VSC Station

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
This paper analyses the distribution of fault current samples for both external and internal faults conditions and quantifies the differences in the features by using the third‐order cumulant and kurtosis. On this basis, a pilot protection scheme was proposed for transmission lines wind farm transmission line connected to VSC station.
Ziliang Wu   +7 more
wiley   +1 more source

Addressing Distance Relay Mal‐Operation in Low‐Inertia Grids: A PLL‐Informed Power Swing Assessment

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
A key advantage of the proposed approach is its independence from PLL control settings, relying solely on locally measured electrical quantities, which ensures robust, fast, and practical implementation in existing commercial distance relays. ABSTRACT The increasing penetration of inverter‐based resources (IBRs) has substantially reduced system inertia
Ahmad Reza Baghaei   +2 more
wiley   +1 more source

Wind–Storage Coordinated Control Strategy for Suppressing Repeated Voltage Ride-Through of Units Under Extreme Weather Conditions

open access: yesEnergies
In practical engineering, large-scale wind power integration typically requires long-distance transmission lines to deliver power to load centers. The resulting weak sending-end systems lack support from synchronous power sources.
Yunpeng Wang   +5 more
doaj   +1 more source

Mitigating Grid Stability Risks From Large AI Data Centres: A Three‐Mode Supervisory Control Framework for Centralized UPS Systems

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
A three‐mode supervisory control framework for centralized data centre UPS systems mitigates the grid stability risks posed by large AI facilities during transmission faults. The framework coordinates current‐limited reactive‐priority allocation, a minimum‐draw policy to limit aggregate load withdrawal and rate‐limited post‐fault recovery, extended to ...
Mohamed Shamseldein
wiley   +1 more source

Analysis and Control of Low-Voltage Ride-Through Capability Improvement for PMSG Based on an NPC Converter Using an Interval Type-2 Fuzzy Logic System

open access: yesElektronika ir Elektrotechnika, 2019
Wind farms must be linked to the grid during the voltage sag. Therefore, the improvement of low-voltage ride-through (LVRT) capability of wind turbine (WT) is a vitally issue. Protection system based on an interval type-2 fuzzy logic system (IT-2 FLC) is
Altan Gencer
doaj   +1 more source

Strengthening Renewable‐Rich Weak Grids Through Improved Voltage Stability and Fault‐Ride Through Capability

open access: yesIET Renewable Power Generation, Volume 20, Issue 1, January/December 2026.
To enhance grid stability and resilience in high renewable energy scenarios, this research proposes a cascaded control optimization framework guided by a novel dynamic resilience metric. Validated on a representative Australian grid, the framework significantly reduced voltage overshoot and extended fault clearing times, offering a robust solution for ...
Sadnan Sakib   +4 more
wiley   +1 more source

A Novel ALTSRCFNN‐STSMC Approach for Enhancing Ride‐Through in Hybrid Renewable Systems

open access: yesIET Renewable Power Generation, Volume 20, Issue 1, January/December 2026.
Simulation results demonstrate that the proposed method reduces voltage recovery time by approximately 25% and improves transient voltage stability by about 15% while satisfying low‐voltage ride‐through (LVRT) grid code requirements. ABSTRACT This paper develops a hybrid adaptive control framework for improving low‐voltage ride‐through (LVRT ...
Kai‐Hung Lu   +3 more
wiley   +1 more source

Hierarchical Response Control Method for Voltage Support in DFIGs Considering Fatigue Loads

open access: yesIET Renewable Power Generation, Volume 20, Issue 1, January/December 2026.
This paper proposes a hierarchical response control (HRC) method to address the increased fatigue load on wind turbines during reactive power support for grid voltage stability. By establishing a fatigue sensitivity model and dynamically adjusting control parameters, the method optimally allocates reactive power while avoiding critical shaft ...
Bin Yang   +7 more
wiley   +1 more source

Low-Voltage Ride-Through Capability of a Single-Stage Single-Phase Photovoltaic System Connected to the Low-Voltage Grid

open access: yesInternational Journal of Photoenergy, 2013
The progressive growing of single-phase photovoltaic (PV) systems makes the Distribution System Operators (DSOs) update or revise the existing grid codes in order to guarantee the availability, quality, and reliability of the electrical system.
Yongheng Yang, Frede Blaabjerg
doaj   +1 more source

Home - About - Disclaimer - Privacy