Results 41 to 50 of about 1,240 (203)
As the grid‐connected interface device of wind and photovoltaic power generation, the voltage source converter (VSC) must pass the low voltage ride‐through (LVRT) test. However, existing literature demonstrates that under weak grid conditions, there is a
Huiqiang Sun +6 more
doaj +1 more source
In the offshore wind farm high-voltage direct-current (HVDC) system, the power delivery capability of the onshore modular multilevel converter (MMC) decreases severely under grid fault, which makes the DC-bus voltage increase rapidly and threatens the ...
Xiaohe Wang +4 more
doaj +1 more source
Abstract In order to study the response characteristics of converters applied in the field of renewable power integration and motor speed regulation when grid fault appears, the traditional LVRT schemes and effects of converters are analyzed, and the integrated design of AC and DC sources scheme based on power electronics technology is ...
Xu Zaide +4 more
openaire +1 more source
Abstract Electric Spring (ES) is an innovative approach for distributed voltage control (DVC) whereas at the same time accomplishing nominal demand-side management (DSM) technique for continuously varying renewable energy sources. In order to demonstrate the efficiency of ES when deployed in enormous quantities across the grid-connected ...
M.D. Udayakumar +4 more
openaire +1 more source
Enabling LVRT Compliance of Electrolyzer Systems Using Energy Storage Technologies
This paper presents a comprehensive techno-economic analysis of different energy storage systems (ESSs) in providing low-voltage ride-through (LVRT) support for power electronics-based electrolyzer systems.
Pankaj Saha +4 more
doaj +1 more source
LVRT Control Strategy For DC Microgrids Considering the Characteristics of PV/Storage/Load
Low voltage ride-through (LVRT) of grid-connected DC microgrid has been driving academic attentions. Firstly, the structure and operation principle of DC microgrids are developed to obtain the analytical expression of DC bus voltage.
Yan LI +4 more
doaj +1 more source
Enhanced wind turbine generator fault ride‐through capability by using hybrid on‐load tap changer
Low‐voltage ride‐through (LVRT) compliance of wind energy conversion systems is one of the significant concerns for both the wind industry and the system operator.
Hazem Karbouj, Zakir Hussain Rather
doaj +1 more source
Fault Ride-Through Control Strategy for Variable Speed Pumped Storage Unit with Full-Size Converter
Fault ride-through is a prerequisite for ensuring continuous operation of a variable-speed pumped storage unit with a full-size converter (FSC-VSPU) and providing support for the renewable energy and power grid.
Huabo Shi +7 more
doaj +1 more source
Mode switching DFIG for low voltage ride through
With the rapid development of world-wide wind energy generation using doubly fed induction generations (DFIGs), low voltage ride through (LVRT) has become a great concern.
Vilathgamuwa, D. Mahinda +3 more
core +1 more source
The capability of a distributed renewable generator (DRG) in providing load low-voltage ride-through (LVRT) is examined. The harnessed renewable power, load demand, and the occurrences of low-voltage incidents are treated as random variables.
Vilathgamuwa, D. Mahinda +4 more
core +1 more source

