Results 31 to 40 of about 22,749,812 (200)
With an increasing share in energy production, wind turbines have to fulfill strict grid requirements to support the grid in case of discontinuities. Here LVRT (Low Voltage Ride Through) compliance is one essential part, where the turbine has to stay ...
Mathias Arbeiter +2 more
doaj +1 more source
Enhanced Low Voltage Ride Through Capability for Grid Connected Wind Energy Conversion System [PDF]
It is obvious that the current era has received much attention in the fields of science and technology, besides the continuous endeavor to provide environmentally friendly and resource-saving alternatives for conventional energy conversion systems.
Althomali, Raed, Alsumiri, Mohammed
core +1 more source
As the grid‐connected interface device of wind and photovoltaic power generation, the voltage source converter (VSC) must pass the low voltage ride‐through (LVRT) test. However, existing literature demonstrates that under weak grid conditions, there is a
Huiqiang Sun +6 more
doaj +1 more source
Abstract In order to study the response characteristics of converters applied in the field of renewable power integration and motor speed regulation when grid fault appears, the traditional LVRT schemes and effects of converters are analyzed, and the integrated design of AC and DC sources scheme based on power electronics technology is ...
Xu Zaide +4 more
openaire +1 more source
Abstract Electric Spring (ES) is an innovative approach for distributed voltage control (DVC) whereas at the same time accomplishing nominal demand-side management (DSM) technique for continuously varying renewable energy sources. In order to demonstrate the efficiency of ES when deployed in enormous quantities across the grid-connected ...
M.D. Udayakumar +4 more
openaire +1 more source
In the offshore wind farm high-voltage direct-current (HVDC) system, the power delivery capability of the onshore modular multilevel converter (MMC) decreases severely under grid fault, which makes the DC-bus voltage increase rapidly and threatens the ...
Xiaohe Wang +4 more
doaj +1 more source
INTRODUCTION: This paper investigates a fault ride-through control strategy for modular multilevel converter (MMC) based converter valves under low-voltage ride-through (LVRT) requirements in large-scale wind power transmission.
Yuhui Chen +3 more
doaj +1 more source
Enhanced wind turbine generator fault ride‐through capability by using hybrid on‐load tap changer
Low‐voltage ride‐through (LVRT) compliance of wind energy conversion systems is one of the significant concerns for both the wind industry and the system operator.
Hazem Karbouj, Zakir Hussain Rather
doaj +1 more source
LVRT Control Strategy For DC Microgrids Considering the Characteristics of PV/Storage/Load
Low voltage ride-through (LVRT) of grid-connected DC microgrid has been driving academic attentions. Firstly, the structure and operation principle of DC microgrids are developed to obtain the analytical expression of DC bus voltage.
Yan LI +4 more
doaj +1 more source
Enabling LVRT Compliance of Electrolyzer Systems Using Energy Storage Technologies
This paper presents a comprehensive techno-economic analysis of different energy storage systems (ESSs) in providing low-voltage ride-through (LVRT) support for power electronics-based electrolyzer systems.
Pankaj Saha +4 more
doaj +1 more source