Results 51 to 60 of about 2,212 (228)
Given the “carbon neutralization and carbon peak” policy, enhancing the low voltage ride-through (LVRT) capability of wind farms has become a current demand to ensure the safe and stable operation of power systems in the context of a possible severe ...
Botong Li +5 more
semanticscholar +1 more source
Fault Ride-Through Control Strategy for Variable Speed Pumped Storage Unit with Full-Size Converter
Fault ride-through is a prerequisite for ensuring continuous operation of a variable-speed pumped storage unit with a full-size converter (FSC-VSPU) and providing support for the renewable energy and power grid.
Huabo Shi +7 more
doaj +1 more source
Improving Low Voltage Ride-through Capabilities for Grid Connected Wind Turbine Generator [PDF]
Low Voltage Ride-Through (LVRT) is one of the most dominant grid connection requirements to be met by Wind Energy Conversion Systems (WECS). In presence of grid voltage dips, a mismatch is produced between the generated active power and the active power ...
Tank, Ishwari +2 more
core +1 more source
Enhancing Low Voltage Ride Through of Microinverters [PDF]
Photovoltaic-based distributed generation (DG) systems are increasingly integrated into the global electrical grid. The existence of numerous DGs in the electrical grid gives rise to concerns about vulnerability, particularly with regard to voltage sag ...
Sharida, Ali +3 more
core +1 more source
Small‐signal modeling reveals that insufficient system damping positions conjugate poles near the imaginary axis, fundamentally explaining the SFR mechanism. A virtual resistance control is consequently proposed to damp the resonance and effectively suppress SFR, which is validated through Hardware‐in‐the‐Loop experiments.
Yujie Gu +3 more
wiley +1 more source
Enhancing LVRT capability of DFIG using cooperative control of BTFCL and RPC
To integrate the high penetration of power from wind farms into a grid, one of the key requirements posed by new grid codes is Low Voltage Ride Through (LVRT) capability. This paper studies voltage compensation-based methods to improve fault ride-through
K. Gireeshma, S. Chandramohan
doaj +1 more source
Under identical conditions, we benchmark PID against Fuzzy‐Logic control for a single‐phase H‐bridge inverter. FLC achieves faster rise/settling with lower THD and better disturbance rejection than tuned PID while requiring explicit rule design—offering a reproducible baseline and deployment guidance for power‐quality‐constrained inverter applications.
Baraa Taha +4 more
wiley +1 more source
Enhancing LVRT Capability of DFIG-Based Wind Turbine Systems with SMES Series in the Rotor Side
The necessary Low Voltage Ride Through (LVRT) capability is very important to wind turbines. This paper presents a method to enhance LVRT capability of doubly fed induction generators- (DFIGs-) based wind turbine systems with series superconducting ...
Xiao Zhou, Yuejin Tang, Jing Shi
doaj +1 more source
Decentralized energy systems are gaining momentum, and microgrids have become a vital component of the modern power landscape. Yet, maintaining power quality within these systems presents ongoing challenges due to the presence of nonlinear loads, variable renewable energy sources, and frequent switching operations.
Mahnoor Zahid +5 more
wiley +1 more source
Ride through Capability of medium-sized Gas Turbine Generators : Modelling and Simulation of Low Voltage Ride through Capability of Siemens Energy's medium-sized GTG and Low Voltage Ride through Grid Codes requirements at point of connection [PDF]
In order to reduce emissions and achieve sustainable energy systems, renewable energy is increasingly being integrated into the power grid. However, the integration of renewable energy into the grid poses several challenges, including maintaining a ...
Almailea, Daniel
core +2 more sources