Results 71 to 80 of about 2,212 (228)
The Research of Verifying Low Voltage Ride through of Double-Fed Wind Turbine Generator System and Voltage Dropping Simulation [PDF]
In order to maintain the stable operation of grid system, the grid company requires wind turbine generator system with low-voltage ride through (LVRT) capability.
Lei Chen +3 more
core +1 more source
Sequence extraction-based low voltage ride-through control of grid-connected renewable energy systems [PDF]
Various faults can cause voltage sag in the power grid at different voltage levels across the network. Balanced or unbalanced voltage sags lead to grid instability by tripping off a large number of wind or solar power plants from the electric power ...
Achour, Y. +17 more
core +1 more source
Preventive Control Considering Stability Constraints for Repeated Low Voltage Ride Through Events
This paper proposes a voltage stability preventive control strategy that accounts for repeated low‐voltage ride‐through characteristics. The method first partitions the system and constructs a short‐term voltage stability assessment index that effectively incorporates repetitive LVRT events, while offline generating a corresponding set of anticipated ...
Zhichong Cao +5 more
wiley +1 more source
Aiming at the problem of low voltage ride through (LVRT) of the generation side uncontrollable rectifying permanent magnet wind turbine in the low voltage microgrid, the operating characteristics of the permanent magnet synchronous generator (PMSG) wind ...
Haichuan ZHAO +3 more
doaj +1 more source
Enhanced critic‐only DQN with smoothing enables continuous SVC control for damping inter‐area oscillations. The state selection via participation and residue analysis captures critical key modes. Orthogonal array efficiently tunes hyperparameters with low cost.
Gunawan Dewantoro +3 more
wiley +1 more source
Symmetrical low voltage ride-through of a 250 kW Brushless DFIG [PDF]
The Brushless Doubly-Fed Induction Generator (Brushless DFIG) shows commercial promise for wind power generation due to its lower cost and higher reliability when compared with the conventional Doubly-Fed Induction Generator (DFIG).
Malliband, P +7 more
core
This paper analyses the distribution of fault current samples for both external and internal faults conditions and quantifies the differences in the features by using the third‐order cumulant and kurtosis. On this basis, a pilot protection scheme was proposed for transmission lines wind farm transmission line connected to VSC station.
Ziliang Wu +7 more
wiley +1 more source
In practical engineering, large-scale wind power integration typically requires long-distance transmission lines to deliver power to load centers. The resulting weak sending-end systems lack support from synchronous power sources.
Yunpeng Wang +5 more
doaj +1 more source
Addressing Distance Relay Mal‐Operation in Low‐Inertia Grids: A PLL‐Informed Power Swing Assessment
A key advantage of the proposed approach is its independence from PLL control settings, relying solely on locally measured electrical quantities, which ensures robust, fast, and practical implementation in existing commercial distance relays. ABSTRACT The increasing penetration of inverter‐based resources (IBRs) has substantially reduced system inertia
Ahmad Reza Baghaei +2 more
wiley +1 more source
Voltage Sag Detection in Grid-Connected Photovoltaic Power Plant for Low Voltage Ride-Through Control [PDF]
Background: Due to the high level of photovoltaic power plants (PVPPs) penetration into power grids, disconnections of these plants during faults are no longer possible as it may cause problems concerning stability, quality, and operation of the power ...
Muhamad Zahim, Sujod, Al-Shetwi, Ali Q.
core +1 more source

