Results 61 to 70 of about 2,212 (228)

Enhancing LVRT Capability of DFIG-Based Wind Turbine Systems with SMES and STATCOM

open access: yesمجلة جامعة الزيتونة, 2022
Nowadays, renewable energy technologies such as a wind turbine have experienced a rapid growth in the world. Doubly Fed Induction Generators (DFIGs) are extensively used in variable speed wind power plants due to their advantages that include reduced ...
Mahmoud Khamaira   +2 more
doaj  

Modeling and Control of a Multi‐Energy Microgrid With Wind LVRT and Battery Pre‐Synchronization Strategy

open access: yesEnergy Science &Engineering, Volume 14, Issue 1, Page 266-280, January 2026.
This study establishes a hybrid microgrid model integrating a Doubly Fed Induction Generator (DFIG), a photovoltaic (PV) array, and a battery energy storage system, and proposes a coordinated control framework. The DFIG regulates DC‐bus voltage through the grid‐side converter and performs maximum power tracking via the rotor‐side converter, while the ...
Chunyan Li   +4 more
wiley   +1 more source

Dynamic Equivalent Model of Two‐Staged Distributed Photovoltaic Cluster Based on Multiple Clustering Algorithms

open access: yesIET Circuits, Devices &Systems, Volume 2026, Issue 1, 2026.
Aiming at the modeling problem of bipolar distributed photovoltaic (DPV) cluster, this paper proposes a clustering equivalent modeling method based on clustering algorithm. First, by analyzing the detailed model of bipolar DPV, it is found that the indexes that can reflect its steady‐state and dynamic characteristics mainly include energy storage ...
Tianyu Zhang, Hassan Haes Alhelou
wiley   +1 more source

An Adaptive Series-Dynamic-Resistor-Based Protection Scheme for Brushless Doubly- Fed Induction Generator Under Asymmetrical Fault Conditions

open access: yesIEEE Access
Low-voltage ride-through (LVRT) is one of the most important criteria for integrating wind energy into the power grid. Based on grid connection codes, wind generators must remain connected during fault conditions.
Mahyar Gholizadeh   +5 more
doaj   +1 more source

Voltage-induced stresses during Low Voltage Ride Through (LVRT) in the drive train of wind turbines with DFIG

open access: yesRE&PQJ
Nowadays   stochastic   occurrence   of   main   grid   disturbances (LVRT,  FRT)  leads  to  high  level  vibrational  excitation  of  the drive train during operation of wind turbines. Regardless  of  the  drivetrain  design  as a  direct,  hybrid  or  multi-stage  geared  one  in  this  case  high  mechanical  and  electrical stresses should be ...
null Dr.-Ing. Jan Wenske   +1 more
openaire   +1 more source

Voltage Control Strategies in Distribution Systems With High Distributed Generation Penetration: Models, Methods and Future Research

open access: yesIET Energy Systems Integration, Volume 8, Issue 1, January/December 2026.
ABSTRACT This paper presents a comprehensive review of recent global research on voltage control in distribution systems with high penetration of distributed generation. First, it examines voltage regulation challenges in distribution systems that integrate distributed generation.
Htutzaw Hein   +6 more
wiley   +1 more source

Low Voltage Ride through Enhancement for Wind Turbines Equipped With DFIG under Symmetrical Grid Faults [PDF]

open access: yes, 2018
In modern power systems with significant penetration of wind-turbines (WTs), improvement of low voltage ride through (LVRT) capability of WTs equipped with doubly-fed induction generators (DFIGs) is an important issue.
Justo , Jackson J., Mwasilu, Francis A.
core   +1 more source

Active Low‐Voltage Ride‐Through Control Strategy for Wind Turbines to Improve Transient Stability in Power Systems

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
Based on the characteristic of wind turbine LVRT influencing system power balance, this study proposes a method utilising active LVRT control to achieve transient stability. A transient stability control strategy is developed by integrating active LVRT with deep reinforcement learning while introducing a disturbance‐level‐based coordinated control ...
Guangyao Yu   +6 more
wiley   +1 more source

Improved Phase Comparison Phase‐to‐Phase Distance Protection for Transmission Lines Connected to Energy Storage Power Stations Based on Polarisation Voltage Phase Reconstruction

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
This paper studies the fault characteristics of the energy storage power station's transmission lines and its influence on the traditional phase comparison distance protection, under different charging and discharging operating conditions. An improved phase comparison distance protection based on polarisation voltage phase reconstruction is proposed ...
Haoyu Zhu   +4 more
wiley   +1 more source

On the compliance of low-voltage ride-through ability of wind turbine generators [PDF]

open access: yes, 2014
As the number of installed wind turbines in the power system increases, it becomes increasingly necessary to ensure the wind turbines can meet the requirement of low-voltage ride-through (LVRT). Currently, there are several techniques to help the
Wang, Zheng
core  

Home - About - Disclaimer - Privacy