Results 81 to 90 of about 2,640 (229)
Voltage sags often disrupt the normal functioning of sensitive equipment and distributed generators (DGs), making voltage sag mitigation based on corresponding assessments crucial. Voltage sag characteristics, including voltage magnitude and sag duration,
Xian-yong Xiao +3 more
doaj +1 more source
Water diversion system of the variable speed pumped storage unit with full‐size converter. ABSTRACT This paper aims to study the frequency‐power coupling dynamic response and regulation characteristics of a variable speed pumped storage unit (VSPSU) with full‐size converter (FSC).
Yanhao Li, Kedong Shu, Wencheng Guo
wiley +1 more source
Study on Low Voltage Ride Through for Direct-drive VSCF Wind Power System
New grid regulation brings forward the requirements on wind turbines for having Low Voltage Ride Through(LVRT)capability and supplying reactive power compensation to the grid during voltage sag prcoess.
张宪平
doaj
Low-voltage ride-through control strategy for permanent magnet synchronous generator under weak grid
In order to improve the low-voltage ride-through(LVRT)capability of permanent magnet synchronous generator(PMSG)under weak grid, this paper proposes a low-voltage ride-through control strategy for power support and auxiliary protection of unloading ...
CHEN Zhong, DING Linzhi, GU Chunsong
doaj +1 more source
Minimising the impact of disturbances in future highly-distributed power systems [PDF]
It is expected that future power systems will require radical distributed control approaches to accommodate the significant expansion of renewable energy sources and other flexible grid devices.
Belloni, F.R. +11 more
core +1 more source
In this paper, we propose a method to effectively identify faults and excitation inrush currents in the area by using the characteristics of instantaneous excitation inductance, so as to improve the reliability and accuracy of low‐frequency transformer protection in offshore wind power low‐frequency transmission system.
Shuping Gao +6 more
wiley +1 more source
Research on the Technology of Low Voltage Ride-through for Grid-connected Photovoltaic Inverter
It analyzes the current commonly used LVRT (low voltage ride-through) solutions, presents a new LVRT SPLL (software phase locked loop) technique which is simpler and faster, and designs a grid-connected PV (photovoltaic) inverter based on the SPLL ...
WANG Nan, CHEN Yifeng, WU Hengliang
doaj
This paper aims to investigate the improvement of the low voltage ride-through (LVRT) in grid-connected photovoltaic (PV) systems by applying the Gold Rush Optimization (GRO) algorithm to design system PI controllers.
Yasmin GH. Mousa +5 more
doaj +1 more source
In this paper, a novel low voltage ride-through (LVRT) technique for three-phase grid-connected inverters is proposed. The proposed technique consists of two parts: a nonlinear phase locked loop based on complex-coefficient filters (NLCCF-PLL) and an ...
Guangyu Sun +4 more
doaj +1 more source
Since the stator of DFIG-based wind turbines is directly connected to the grid, it is dramatically affected by transient situations that may occur on the grid side. In order to meet grid code requirements, reactive power support must be provided to keep the DFIG connected to the grid during the transient state. To achieve this, Low Voltage Ride Through
M. Kenan Döşoğlu, Muhsin Uğur Doğan
openaire +2 more sources

