Results 81 to 90 of about 2,640 (229)

Voltage sag assessment method considering low-voltage ride-through of inverter-interfaced distributed generators

open access: yesInternational Journal of Electrical Power & Energy Systems
Voltage sags often disrupt the normal functioning of sensitive equipment and distributed generators (DGs), making voltage sag mitigation based on corresponding assessments crucial. Voltage sag characteristics, including voltage magnitude and sag duration,
Xian-yong Xiao   +3 more
doaj   +1 more source

Frequency‐Power Coupling Dynamic Response and Regulation Characteristics of Variable Speed Pumped Storage Unit With Full‐Size Converter

open access: yesEnergy Science &Engineering, Volume 13, Issue 2, Page 811-832, February 2025.
Water diversion system of the variable speed pumped storage unit with full‐size converter. ABSTRACT This paper aims to study the frequency‐power coupling dynamic response and regulation characteristics of a variable speed pumped storage unit (VSPSU) with full‐size converter (FSC).
Yanhao Li, Kedong Shu, Wencheng Guo
wiley   +1 more source

Study on Low Voltage Ride Through for Direct-drive VSCF Wind Power System

open access: yesKongzhi Yu Xinxi Jishu, 2010
New grid regulation brings forward the requirements on wind turbines for having Low Voltage Ride Through(LVRT)capability and supplying reactive power compensation to the grid during voltage sag prcoess.
张宪平
doaj  

Low-voltage ride-through control strategy for permanent magnet synchronous generator under weak grid

open access: yesDiance yu yibiao
In order to improve the low-voltage ride-through(LVRT)capability of permanent magnet synchronous generator(PMSG)under weak grid, this paper proposes a low-voltage ride-through control strategy for power support and auxiliary protection of unloading ...
CHEN Zhong, DING Linzhi, GU Chunsong
doaj   +1 more source

Minimising the impact of disturbances in future highly-distributed power systems [PDF]

open access: yes, 2017
It is expected that future power systems will require radical distributed control approaches to accommodate the significant expansion of renewable energy sources and other flexible grid devices.
Belloni, F.R.   +11 more
core   +1 more source

A Low‐Frequency Transformer Protection Method Based on Excitation Inductance Parameter Identification

open access: yesIET Electric Power Applications, Volume 19, Issue 1, January/December 2025.
In this paper, we propose a method to effectively identify faults and excitation inrush currents in the area by using the characteristics of instantaneous excitation inductance, so as to improve the reliability and accuracy of low‐frequency transformer protection in offshore wind power low‐frequency transmission system.
Shuping Gao   +6 more
wiley   +1 more source

Research on the Technology of Low Voltage Ride-through for Grid-connected Photovoltaic Inverter

open access: yesKongzhi Yu Xinxi Jishu, 2013
It analyzes the current commonly used LVRT (low voltage ride-through) solutions, presents a new LVRT SPLL (software phase locked loop) technique which is simpler and faster, and designs a grid-connected PV (photovoltaic) inverter based on the SPLL ...
WANG Nan, CHEN Yifeng, WU Hengliang
doaj  

Comparative analysis of metaheuristic algorithms-based control for enhancing low voltage ride through in grid-connected photovoltaic systems

open access: yesAin Shams Engineering Journal
This paper aims to investigate the improvement of the low voltage ride-through (LVRT) in grid-connected photovoltaic (PV) systems by applying the Gold Rush Optimization (GRO) algorithm to design system PI controllers.
Yasmin GH. Mousa   +5 more
doaj   +1 more source

A Novel Low Voltage Ride-Through Technique of Three-Phase Grid-Connected Inverters Based on a Nonlinear Phase-Locked Loop

open access: yesIEEE Access, 2019
In this paper, a novel low voltage ride-through (LVRT) technique for three-phase grid-connected inverters is proposed. The proposed technique consists of two parts: a nonlinear phase locked loop based on complex-coefficient filters (NLCCF-PLL) and an ...
Guangyu Sun   +4 more
doaj   +1 more source

Enhancement of Low Voltage Ride Through (LVRT) Capability of DFIG-Based Wind Turbines with Enhanced Demagnetization Control Model

open access: yesEnergies
Since the stator of DFIG-based wind turbines is directly connected to the grid, it is dramatically affected by transient situations that may occur on the grid side. In order to meet grid code requirements, reactive power support must be provided to keep the DFIG connected to the grid during the transient state. To achieve this, Low Voltage Ride Through
M. Kenan Döşoğlu, Muhsin Uğur Doğan
openaire   +2 more sources