Results 141 to 150 of about 5,131 (213)
Some of the next articles are maybe not open access.
2013 12th International Conference on Environment and Electrical Engineering, 2013
Nowadays wind turbines are generally required to offer ancillary services similar to those provided by conventional generators. One of the most important services wind turbines must offer is to stay connected to the grid in fault situations delivering the reactive current specified in the recent grid codes.
H. Amaris +3 more
openaire +1 more source
Nowadays wind turbines are generally required to offer ancillary services similar to those provided by conventional generators. One of the most important services wind turbines must offer is to stay connected to the grid in fault situations delivering the reactive current specified in the recent grid codes.
H. Amaris +3 more
openaire +1 more source
LVRT-DGFACTS devices in wind farms
2011 International Conference on Power Engineering, Energy and Electrical Drives, 2011This article compares the results recorded in the connection of three types of DGFACTS (DSTATCOM, DVR, UPQC) to a wind farm in order to resolve the issues of LVRT requirements on wind farms equipped with wind turbines with squirrel-cage induction generators.
Melchor Gomez +4 more
openaire +1 more source
IEEE Transactions on Power Systems, 2023
With large scale of wind turbines connected to high impedance AC grid, transient synchronizing stability of PLL (phase locked loop) based WTC (wind turbine converter) during LVRT (low voltage ride through) is increasing concerned.
Qi Hu +5 more
semanticscholar +1 more source
With large scale of wind turbines connected to high impedance AC grid, transient synchronizing stability of PLL (phase locked loop) based WTC (wind turbine converter) during LVRT (low voltage ride through) is increasing concerned.
Qi Hu +5 more
semanticscholar +1 more source
IEEE transactions on power electronics, 2023
The low-voltage ride-through (LVRT) capability of the doubly-fed induction generator (DFIG) based on the conventional excitation converter is insufficient under severe grid faults.
Jia-Teng Gu +6 more
semanticscholar +1 more source
The low-voltage ride-through (LVRT) capability of the doubly-fed induction generator (DFIG) based on the conventional excitation converter is insufficient under severe grid faults.
Jia-Teng Gu +6 more
semanticscholar +1 more source
Control Strategy Study of DFIG with LVRT
2009 International Conference on Energy and Environment Technology, 2009In recent years, the proportion of the wind power in the grid is increasing rapidly. When the grids faults results in voltage decline, the widespread tripping of wind generators could lead to transient instabilities and local or overall blackouts. So it is concerned that the wind turbines merge into the grid and the request of the low voltage ride ...
Xing-jia Yao +3 more
openaire +1 more source
IEEE Transactions on Sustainable Energy, 2023
Similar to emerging regional grid codes, the recently approved IEEE 2800 Standard mandates that inverter-based resources (IBRs) generate negative-sequence current during low-voltage ride-through (LVRT) conditions. The 2800 Standard requires that the IBRs'
H. Mohammadpour +3 more
semanticscholar +1 more source
Similar to emerging regional grid codes, the recently approved IEEE 2800 Standard mandates that inverter-based resources (IBRs) generate negative-sequence current during low-voltage ride-through (LVRT) conditions. The 2800 Standard requires that the IBRs'
H. Mohammadpour +3 more
semanticscholar +1 more source
Study on Transient Characteristic of the DFIG LVRT
Advanced Materials Research, 2013In order to analyze the operational capability of the low voltage ride through ( LVRT) of a gird-connected wind turbine with doubly fed induction generator (DFIG) effectively, it is necessary to evaluate operation characteristics of DFIG under a grid fault.By using the transient principle of the flux of stator and rotor, the expressions of transient ...
Jian Hua Zhang, Rong Luan, Hao Ran Shen
openaire +1 more source
New interconnection standards for Photovoltaic systems are going to be mandatory in some countries. Such that the next generation of PV should support a full range of operation mode like in a power plant and also support Low-Voltage Ride-Through (LVRT ...
Frede Blaabjerg +2 more
exaly +2 more sources
IEEE Journal of Emerging and Selected Topics in Power Electronics, 2023
This article proposes a novel multiobjective control strategy (MOCS) for improving the performance of grid-tied photovoltaic (GTPV) system without phase-locked loop (PLL) operating under abnormal grid voltage conditions such as harmonically distorted ...
M. K. Mishra, V. Lal
semanticscholar +1 more source
This article proposes a novel multiobjective control strategy (MOCS) for improving the performance of grid-tied photovoltaic (GTPV) system without phase-locked loop (PLL) operating under abnormal grid voltage conditions such as harmonically distorted ...
M. K. Mishra, V. Lal
semanticscholar +1 more source
IEEE transactions on industry applications, 2023
This article presents an adaptive neuro-fuzzy based direct power control (DPC) scheme for a grid connected doubly fed induction generator (DFIG) based wind energy conversion system (WECS) incorporated with distance protection and low voltage ride-through
Mohammad Nasir Uddin +2 more
semanticscholar +1 more source
This article presents an adaptive neuro-fuzzy based direct power control (DPC) scheme for a grid connected doubly fed induction generator (DFIG) based wind energy conversion system (WECS) incorporated with distance protection and low voltage ride-through
Mohammad Nasir Uddin +2 more
semanticscholar +1 more source