A comprehensive review of LVRT capability and sliding mode control of grid-connected wind-turbine-driven doubly fed induction generator [PDF]

open access: yesAutomatika, 2016
U ovom radu, prikazan je sveobuhvatan pregled strategija primjenjenih za poboljšanje sposobnosti rada tijekom prolaznih smetnji niskog napona mreže za vjetroagregat s dvostruko napajanim asinkronim generatorom (DFIG).
Larbi Boumediene, Abdelkader Mezouar
exaly   +2 more sources

A Dynamic LVRT Solution for Doubly Fed Induction Generators

IEEE Transactions on Power Electronics, 2009
Doubly fed induction generators have become the most common type of wind turbine generators. However, this type of generator is susceptible to grid-side low voltage and short circuits due to existence of a power electronics converter on the rotor side.
Omar Abdel-Baqi, Adel Nasiri
openaire   +1 more source

Impact of ASD settings in its LVRT behaviour

SPEEDAM 2010, 2010
A common matter of concern in industrial installations is that adjustable-speed drives (ASD) trip due to voltage sags. ASD manufacturers are including more and more in these devices settings related to control strategies (e.g. allowable DC voltage levels, etc) in order to improve their Low Voltage Ride Through (LVRT).
C. Carrillo   +4 more
openaire   +1 more source

A Technical Review on LVRT of DFIG Systems

2016
The most important issue with doubly fed induction generator (DFIG) wind turbine is low voltage ride-through performance. To solve this problem, several techniques have been introduced. The paper discusses some of the most commonly used solutions for Low Voltage Ride Through (LVRT) of wind turbine generators which is the most important feature to be ...
Pretty Mary Tom   +4 more
openaire   +1 more source

LVRT-retardation-device for decentralized power plants

2014 Electric Power Quality and Supply Reliability Conference (PQ), 2014
During fault events in the electrical power grid nearby a synchronous generator, the rotor speed of the machine is increased, because dissipated power is below generated power. This may cause high rotor angle excursions and hence the machine to lose synchronism with the power grid.
Norbert Essl, Herwig Renner
openaire   +1 more source

Dynamic Coupling Analysis and Small-Signal Stability for Multi-Parallel PLL-Synchronous VSC-Based Renewable Energy Plants During Asymmetrical LVRT

IEEE Transactions on Sustainable Energy, 2023
Studying the small-signal stability for multi-parallel voltage source converter (VSC)-based renewable energy plants (REPs) during the fault steady-state of low-voltage ride-through (LVRT) in weak grid is significant for designing a stabilized controller ...
Lei Guan, Jun Yao
semanticscholar   +1 more source

A Multi-Objective Bi-Level LVRT Control Strategy for Two-Stage PV Grid-Connected System Under Asymmetrical Faults

IEEE Transactions on Sustainable Energy
With the increasing integration of photovoltaics (PV) into power systems, the low-voltage ride-through (LVRT) control of PV grid-connected systems is drawing significant attention.
Yiqian Wang   +7 more
semanticscholar   +1 more source

An adaptive fuzzy logic control technique for LVRT enhancement of a grid-integrated DFIG-based wind energy conversion system.

ISA transactions, 2023
The fast improvement of wind energy conversion technology with optimization algorithms has recently received a lot of attention. However, their slow convergence speed, huge computational load, and low efficiency are the main drawbacks and to improve ...
Arindam Chakraborty, T. Maity
semanticscholar   +1 more source

Research on LVRT capability of DFIG with demagnetization control

2013 IEEE Energy Conversion Congress and Exposition, 2013
With the stator directly connected to the grid, doubly-fed induction generator is very sensitive to grid disturbance. Demagnetization control depresses the influence of grid fault by accelerating the damping of natural stator flux linkage, improving the performance of doubly-fed induction generator.
Linyuan Zhou   +3 more
openaire   +1 more source

A method of evaluating LVRT capability of wind turbines

2017 IEEE 2nd Advanced Information Technology, Electronic and Automation Control Conference (IAEAC), 2017
The low voltage ride through capability is an important aspect of the operation safety of the wind farm. According to the situation of the lack of effective monitoring of wind turbine operation, a online tracking quantitative evaluation method of wind turbine low voltage ride through capability (LVRT) is brought forward.
Han Yu   +6 more
openaire   +1 more source