Results 51 to 60 of about 608 (186)

Preventive Control Considering Stability Constraints for Repeated Low Voltage Ride Through Events

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
This paper proposes a voltage stability preventive control strategy that accounts for repeated low‐voltage ride‐through characteristics. The method first partitions the system and constructs a short‐term voltage stability assessment index that effectively incorporates repetitive LVRT events, while offline generating a corresponding set of anticipated ...
Zhichong Cao   +5 more
wiley   +1 more source

Value‐Based Reinforcement Learning for Inter‐Area Oscillations Mitigation in PV‐Integrated Power Systems

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
Enhanced critic‐only DQN with smoothing enables continuous SVC control for damping inter‐area oscillations. The state selection via participation and residue analysis captures critical key modes. Orthogonal array efficiently tunes hyperparameters with low cost.
Gunawan Dewantoro   +3 more
wiley   +1 more source

Admittance‑Based Two‑Stage Optimisation of GFM‑STATCOM Parameters for Transient Voltage Support in DFIG Wind Farms

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
This paper builds an admittance model for a DFIG‐STATCOM parallel system. Based on the system, the paper provides a method to optimise the control of the STATCOM, which aims to increase the performance of the system during symmetrical faults .
Wenhao Du   +5 more
wiley   +1 more source

Higher‐Order Statistics Based Pilot Protection Scheme for Wind Farm Transmission Line Connected to VSC Station

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
This paper analyses the distribution of fault current samples for both external and internal faults conditions and quantifies the differences in the features by using the third‐order cumulant and kurtosis. On this basis, a pilot protection scheme was proposed for transmission lines wind farm transmission line connected to VSC station.
Ziliang Wu   +7 more
wiley   +1 more source

Addressing Distance Relay Mal‐Operation in Low‐Inertia Grids: A PLL‐Informed Power Swing Assessment

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
A key advantage of the proposed approach is its independence from PLL control settings, relying solely on locally measured electrical quantities, which ensures robust, fast, and practical implementation in existing commercial distance relays. ABSTRACT The increasing penetration of inverter‐based resources (IBRs) has substantially reduced system inertia
Ahmad Reza Baghaei   +2 more
wiley   +1 more source

Mitigating Grid Stability Risks From Large AI Data Centres: A Three‐Mode Supervisory Control Framework for Centralized UPS Systems

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
A three‐mode supervisory control framework for centralized data centre UPS systems mitigates the grid stability risks posed by large AI facilities during transmission faults. The framework coordinates current‐limited reactive‐priority allocation, a minimum‐draw policy to limit aggregate load withdrawal and rate‐limited post‐fault recovery, extended to ...
Mohamed Shamseldein
wiley   +1 more source

Strengthening Renewable‐Rich Weak Grids Through Improved Voltage Stability and Fault‐Ride Through Capability

open access: yesIET Renewable Power Generation, Volume 20, Issue 1, January/December 2026.
To enhance grid stability and resilience in high renewable energy scenarios, this research proposes a cascaded control optimization framework guided by a novel dynamic resilience metric. Validated on a representative Australian grid, the framework significantly reduced voltage overshoot and extended fault clearing times, offering a robust solution for ...
Sadnan Sakib   +4 more
wiley   +1 more source

A Novel ALTSRCFNN‐STSMC Approach for Enhancing Ride‐Through in Hybrid Renewable Systems

open access: yesIET Renewable Power Generation, Volume 20, Issue 1, January/December 2026.
Simulation results demonstrate that the proposed method reduces voltage recovery time by approximately 25% and improves transient voltage stability by about 15% while satisfying low‐voltage ride‐through (LVRT) grid code requirements. ABSTRACT This paper develops a hybrid adaptive control framework for improving low‐voltage ride‐through (LVRT ...
Kai‐Hung Lu   +3 more
wiley   +1 more source

Low voltage ride-through capability improvement methods for DFIG based wind farm

open access: yesJournal of Electrical Systems and Information Technology, 2018
In this paper the low voltage ride-through (LVRT) capability enhancement of the DFIG based wind farm (WF) is accomplished by using of the existing series devices like the new bridge type fault current limiter (NBFCL), new solid-state fault current ...
Md Emrad Hossain
doaj   +1 more source

A Virtual Synchronous Generator Low-Voltage Ride-Through Control Strategy Considering Complex Grid Faults

open access: yesApplied Sciences
The Virtual Synchronous Generator (VSG) control strategy has garnered widespread application during the low-voltage ride-through (LVRT) of distributed energy resources integrated into power grids, primarily due to its inertia and damping properties ...
Jun Yin   +3 more
doaj   +1 more source

Home - About - Disclaimer - Privacy