Results 51 to 60 of about 554 (136)

Voltage Control Strategies in Distribution Systems With High Distributed Generation Penetration: Models, Methods and Future Research

open access: yesIET Energy Systems Integration, Volume 8, Issue 1, January/December 2026.
ABSTRACT This paper presents a comprehensive review of recent global research on voltage control in distribution systems with high penetration of distributed generation. First, it examines voltage regulation challenges in distribution systems that integrate distributed generation.
Htutzaw Hein   +6 more
wiley   +1 more source

Research on low voltage ride-through strategies for doubly-fed wind farms during asymmetric faults

open access: yesInternational Journal of Electrical Power & Energy Systems
This paper addresses the issue of enhancing the low voltage ride-through (LVRT) capability of doubly-fed wind farms during asymmetric faults. This research is of critical importance for ensuring the safe and stable operation of the power grid and the ...
Li Botong   +5 more
doaj   +1 more source

Active Low‐Voltage Ride‐Through Control Strategy for Wind Turbines to Improve Transient Stability in Power Systems

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
Based on the characteristic of wind turbine LVRT influencing system power balance, this study proposes a method utilising active LVRT control to achieve transient stability. A transient stability control strategy is developed by integrating active LVRT with deep reinforcement learning while introducing a disturbance‐level‐based coordinated control ...
Guangyao Yu   +6 more
wiley   +1 more source

Improved Phase Comparison Phase‐to‐Phase Distance Protection for Transmission Lines Connected to Energy Storage Power Stations Based on Polarisation Voltage Phase Reconstruction

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
This paper studies the fault characteristics of the energy storage power station's transmission lines and its influence on the traditional phase comparison distance protection, under different charging and discharging operating conditions. An improved phase comparison distance protection based on polarisation voltage phase reconstruction is proposed ...
Haoyu Zhu   +4 more
wiley   +1 more source

Preventive Control Considering Stability Constraints for Repeated Low Voltage Ride Through Events

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
This paper proposes a voltage stability preventive control strategy that accounts for repeated low‐voltage ride‐through characteristics. The method first partitions the system and constructs a short‐term voltage stability assessment index that effectively incorporates repetitive LVRT events, while offline generating a corresponding set of anticipated ...
Zhichong Cao   +5 more
wiley   +1 more source

Value‐Based Reinforcement Learning for Inter‐Area Oscillations Mitigation in PV‐Integrated Power Systems

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
Enhanced critic‐only DQN with smoothing enables continuous SVC control for damping inter‐area oscillations. The state selection via participation and residue analysis captures critical key modes. Orthogonal array efficiently tunes hyperparameters with low cost.
Gunawan Dewantoro   +3 more
wiley   +1 more source

Admittance‑Based Two‑Stage Optimisation of GFM‑STATCOM Parameters for Transient Voltage Support in DFIG Wind Farms

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
This paper builds an admittance model for a DFIG‐STATCOM parallel system. Based on the system, the paper provides a method to optimise the control of the STATCOM, which aims to increase the performance of the system during symmetrical faults .
Wenhao Du   +5 more
wiley   +1 more source

Higher‐Order Statistics Based Pilot Protection Scheme for Wind Farm Transmission Line Connected to VSC Station

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
This paper analyses the distribution of fault current samples for both external and internal faults conditions and quantifies the differences in the features by using the third‐order cumulant and kurtosis. On this basis, a pilot protection scheme was proposed for transmission lines wind farm transmission line connected to VSC station.
Ziliang Wu   +7 more
wiley   +1 more source

Addressing Distance Relay Mal‐Operation in Low‐Inertia Grids: A PLL‐Informed Power Swing Assessment

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
A key advantage of the proposed approach is its independence from PLL control settings, relying solely on locally measured electrical quantities, which ensures robust, fast, and practical implementation in existing commercial distance relays. ABSTRACT The increasing penetration of inverter‐based resources (IBRs) has substantially reduced system inertia
Ahmad Reza Baghaei   +2 more
wiley   +1 more source

Mitigating Grid Stability Risks From Large AI Data Centres: A Three‐Mode Supervisory Control Framework for Centralized UPS Systems

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
A three‐mode supervisory control framework for centralized data centre UPS systems mitigates the grid stability risks posed by large AI facilities during transmission faults. The framework coordinates current‐limited reactive‐priority allocation, a minimum‐draw policy to limit aggregate load withdrawal and rate‐limited post‐fault recovery, extended to ...
Mohamed Shamseldein
wiley   +1 more source

Home - About - Disclaimer - Privacy