Results 61 to 70 of about 7,162 (246)
Fast Coordinated Control of DFIG Wind Turbine Generators for Low and High Voltage Ride-Through [PDF]
This paper presents a fast coordinated control scheme of the rotor side converter (RSC), the Direct Current (DC) chopper and the grid side converter (GSC) of doubly fed induction generator (DFIG) wind turbine generators (WTGs) to improve the low voltage ...
Ackermann +7 more
core +2 more sources
This study aims to improve the low-voltage ride-through (LVRT) capabilities of wind power plants (WPPs) during various types of grid faults, such as line-to-ground (L-G), double line-to-ground (LL-G), line-to-line (L-L), and three-phase-to-ground (LLL-G)
Abdallah Fouad +6 more
semanticscholar +1 more source
This paper focuses on enhancing the resilience of Power Park Modules (PPMs), connected to the grid via power electronic units, under asymmetrical voltage sag conditions.
Fathia Letaief +3 more
semanticscholar +1 more source
The terminal-connected series dynamic braking resistor (SDBR) is applied to assist the low-voltage ride-through (LVRT) of the doubly-fed induction generator (DFIG). With the fault current and switch-in of the SDBR, the stator voltage oscillates, thus the
Jieie Huang +7 more
semanticscholar +1 more source
FAULT RIDE-THROUGH CAPABILITY AND DAMPING IMPROVEMENT IN DFIG [PDF]
Doubly-fed induction generator wind turbine is susceptible to faults and requires crowbar protection. When the crowbar is triggered, the rotor is short circuited over the crowbar impedance.
Dolara, Alberto +5 more
core
Advanced Control Strategy of DFIG Wind Turbines for Power System Fault Ride Through [PDF]
This paper presents an advanced control strategy for the rotor and grid side converters of the doubly fed induction generator (DFIG) based wind turbine (WT) to enhance the low-voltage ride-through (LVRT) capability according to the grid connection ...
Dong, Zhao Yang +4 more
core +2 more sources
Research on low voltage ride-through strategies for doubly-fed wind farms during asymmetric faults
This paper addresses the issue of enhancing the low voltage ride-through (LVRT) capability of doubly-fed wind farms during asymmetric faults. This research is of critical importance for ensuring the safe and stable operation of the power grid and the ...
Li Botong +5 more
doaj +1 more source
Reactive current injection protocol for low-power rating distributed generation sources under voltage sags [PDF]
Voltage sags are one of the main problems in transmission and distribution networks. This study proposes a voltage support control scheme for grid-connected low-power rating inverters under voltage sags.
Camacho Santiago, Antonio +4 more
core +2 more sources
A P-Q Coordination Control Strategy of VSC-HVDC and BESS for LVRT Recovery Performance Enhancement
Voltage source converter (VSC)-based multi-terminal direct current (MTDC) transmission technology has been a research focus, and the low-voltage ride-through (LVRT) and recovery in receiving-end systems is one of the major problems to consider.
Zhen Wang +3 more
semanticscholar +1 more source
Study on a small‐signal analysis method for PMSG considering LVRT control and frequency regulation
In a high proportion of new energy grids or a 100% new energy source of power grid, the dynamic performance of PMSG under fault conditions is very important.
Fan Xiao +5 more
doaj +1 more source

