Results 251 to 260 of about 20,132,521 (307)
Analytical Synthesis of Current-Mode High-Order OTA-C Filters
Chang, Chun-Ming, Al-Hashimi, Bashir M.
core
Some of the next articles are maybe not open access.
Related searches:
Related searches:
M-Mode Ultrasonography in Ocular Emergencies
International Journal of Research and Scientific Innovation, 2022M-Mode, or time-motion display, allows a single beam to emit from the ultrasound transducer along a defined track in conjunction with a recorder that captures all motions that occurs along the path. This mode allows high temporal resolution, thus affording the examiner an excellent view of subtle motions.
Hadi Khazaei +4 more
openaire +1 more source
M-mode echocardiographic values in sheep
American Journal of Veterinary Research, 1987SUMMARY M-mode echocardiograms were recorded from 21 adult sheep (20 ewes, 1 whether). Fifteen echocardiographic measurements were taken and compared with body weights or heart rates, using linear regression equations. Significant correlations (P < 0.05) were found when body weight was compared with left ventricular internal dimensions in systole ...
B L, Moses, J N, Ross
openaire +2 more sources
The M-mode echocardiogram in Fabry's disease
American Heart Journal, 1980Fabry's disease results from deficient activity of the enzyme alpha-galactosidase A. Cardiac abnormalities result from glycosphingolipid deposition in the myocardium, valvular tissue, and vessel walls. A noninvasive method to examine these abnormalities would be useful in the evaluation of patients.
J L, Bass +4 more
openaire +2 more sources
Ultrasonic M-Mode Technique in Ophthalmology
Archives of Ophthalmology, 1969The use of the M-mode or time-dependent intensity modulated ultrasound technique for ophthalmologic investigations is described. This technique provides the investigator with a means for monitoring structural changes in the eye during physiologic or pharmacologic experimental conditions, or a combination of both, and is particularly useful in studying ...
D J, Coleman, R, Weininger
openaire +2 more sources
Auto-biometric for M-mode echocardiography
SPIE Proceedings, 2010In this paper we present a system for fast and accurate detection of anatomical structures (calipers) in M-mode images. The task is challenging because of dramatic variations in their appearances. We propose to solve the problem in a progressive manner, which ensures both robustness and efficiency.
Wei Zhang 0018 +2 more
openaire +1 more source
Pitfalls and limitations of M-mode echocardiography
American Heart Journal, 1977Newer diagnostic applications as well as the ability of obtaining physiologic information has resulted in a greater interest in echocardiography. As with any new technique, certain classical criteria have not been found to be as specific and diagnostic as was originally believed.
M N, Kotler +3 more
openaire +2 more sources
Video controlled M‐mode biometry
Acta Ophthalmologica Scandinavica, 1995ABSTRACT To increase the accuracy of intraocular lens power calculation, an interface between an ultrasonic A‐scanning device and a personal computer was created, allowing for an on‐line interpretation of the ultrasonogram in an M‐mode fashion. On the same computer display, a video recording of the movements of the transducer probe relative to the eye ...
P K, Jensen, R, Rask, T, Olsen
openaire +2 more sources
Anatomical M‐Mode: An Old–New Technique
Echocardiography, 2003The M‐mode (motion mode) technique has improved the diagnostic possibilities of echocardiography due to its high temporal resolution. The use of a two‐dimensional (2D) image as a basis for M‐mode analysis at a defined line, independent of the transducer orientation, namely the anatomic M‐mode (AMM), has been proposed from the beginning of 2D ...
CARERJ, Scipione +9 more
openaire +3 more sources
Echocardiography: M-Mode and Two-Dimensional Methods
Annals of Internal Medicine, 1980We review the basic similarities and differences of currently used M-mode and two-dimensional (2D) echocardiography. Discrete categories of disease are used to show the relative strengths of M-mode and 2D methods. The format of 2D echocardiography is well suited to analyze congenital heart disease, consequences of coronary artery disease, and ...
R L, Popp +3 more
openaire +2 more sources