Results 41 to 50 of about 28,693,335 (281)

Inebilizumab in AQP4‐Seropositive NMOSD: One‐Year Follow‐Up From a Multicenter, Real‐World Study

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective Real‐world evidence on inebilizumab among neuromyelitis optica spectrum disorder (NMOSD) patients is lacking. This study assessed inebilizumab among Chinese patients with aquaporin 4 autoantibody (AQP4‐IgG)‐seropositive NMOSD in a real‐world setting.
Mengcui Gui   +10 more
wiley   +1 more source

Right ventricular function in transcatheter mitral and tricuspid valve edge-to-edge repair

open access: yesFrontiers in Cardiovascular Medicine, 2022
Since transcatheter edge-to-edge repair (TEER) has become a valuable therapy in the treatment of both, mitral (MR) and tricuspid regurgitation (TR), the question of optimized patient selection has gained growing importance.
Lukas Stolz   +18 more
doaj   +1 more source

James Teer Interview, March 24, 1996 [PDF]

open access: yes, 1996
James Teer discusses the Boone and Crockett Club and how he became a member in the early 1970s because of the Club’s accomplishments in conservation. He talks about the Club’s decision to acquire the Theodore Roosevelt Memorial Ranch in Montana and the ...
Teer, James
core  

Safety and Effectiveness of Concomitant Mitral Transcatheter Edge-to-Edge Repair and Left Atrial Appendage Closure

open access: yes, 2023
Background: Concomitant mitral transcatheter edge-to-edge repair (M-TEER) and left atrial appendage closure (LAAC) showed to be a feasible approach to optimize the treatment of patients eligible for both procedures, but mid-term outcomes are unclear ...
Maria Elena Di Salvo   +14 more
core   +1 more source

Printed Integrated Logic Circuits Based on Chitosan‐Gated Organic Transistors for Future Edible Systems

open access: yesAdvanced Functional Materials, EarlyView.
Edible electronics needs integrated logic circuits for computation and control. This work presents a potentially edible printed chitosan‐gated transistor with a design optimized for integration in circuits. Its implementation in integrated logic gates and circuits operating at low voltage (0.7 V) is demonstrated, as well as the compatibility with an ...
Giulia Coco   +8 more
wiley   +1 more source

Evolution of tricuspid regurgitation after transcatheter edge-to-edge mitral valve repair for secondary mitral regurgitation and its impact on mortality [PDF]

open access: yes, 2022
Aim To evaluate short-term changes in tricuspid regurgitation (TR) after transcatheter edge-to-edge mitral valve repair (M-TEER) in secondary mitral regurgitation (SMR), their predictors and impact on mortality.
Fernández-Vázquez, Felipe   +105 more
core   +1 more source

Counterion Dependent Side‐Chain Relaxation Stiffens a Chemically Doped Thienothiophene Copolymer

open access: yesAdvanced Functional Materials, EarlyView.
Oxidation of a thienothiophene copolymer, p(g3TT‐T2), via different doping strategies and dopant molecules resulted in materials with similar oxidation levels and a high electrical conductivity of ≈100 S cm−1. However, mechanical properties varied significantly, with sub‐glass transition temperatures and elastic moduli spanning from –44°C to –3°C and ...
Mariavittoria Craighero   +12 more
wiley   +1 more source

Evolution of Clinical Indications for Mitral Valve Transcatheter Edge-to-Edge Repair

open access: yesReviews in Cardiovascular Medicine
Mitral valve transcatheter edge-to-edge repair (M-TEER) has evolved from a highly specialized intervention to an essential treatment option for patients with severe mitral regurgitation (MR) who are unsuitable candidates for surgery.
Carla Iglesias-Otero   +4 more
doaj   +1 more source

Evaluating Mitral TEER in the Management of Moderate Secondary Mitral Regurgitation Among Heart Failure Patients [PDF]

open access: yes
Background: Moderate secondary mitral regurgitation (SMR) represents a subgroup of heart failure (HF) patients with treatment restricted to medical therapy.
von Bardeleben R. S.   +16 more
core   +1 more source

Implantable Ionic Memristors Based on Natural Polymer Heterojunctions

open access: yesAdvanced Functional Materials, EarlyView.
We report an implantable natural polymer‐based ionic memristor composed of hyaluronic acid, chitosan, and PDMS. The device achieved 98.94% accuracy in MNIST classification while reducing training time by 36.8% compared with a conventional artificial neural network (ANN).
Dong‐yup Lee   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy