Results 171 to 180 of about 2,693 (205)
Some of the next articles are maybe not open access.

A Study of the Quantitative Nondestructive Evaluation Using the Cross Type Magnetic Source and the Magnetic Camera

Key Engineering Materials, 2006
The magnetic camera using magnetic lens is proposed to satisfy the demands such as obtaining the distribution of the magnetic flux leakage (DMFL) on the high lift-off, and improving sensitivity. However, DMFL is strongly affected by the magnetization direction. Therefore, the DMFL has low intensity when the crack is not perpendicular to the magnetizing
Jin Yi Lee, Ji Seong Hwang
openaire   +1 more source

Measurement of Acoustic Properties of Magnetic Fluid and Its Application to Nondestructive Evaluation

Japanese Journal of Applied Physics, 1994
The ultrasonic velocity in a magnetic fluid (MF) on a base of water is measured under different temperatures, frequencies and magnetic fields. Two Kinds of ultrasonic correlation systems are employed. The maximum velocity is observed at 38°C without distinction of frequency.
Kazuhiko Imano Kazuhiko Imano   +1 more
openaire   +1 more source

Nondestructive Evaluation of Magnetic Disk Heads Using a Photoacoustic Microscope

Japanese Journal of Applied Physics, 1997
Nondestructive evaluation of magnetic disk heads is achieved using a photoacoustic microscope (PAM). A qualitative evaluation for gap or an isolation area of the heads is performed with photoacoustic amplitude and phase images. Resolution achieved is about 2 micrometer. A crack in a ferrite region and a bubble in a glass filler is observed
openaire   +1 more source

Nondestructive evaluation of magnetic materials by ferromagnetic-resonance photothermal-deflection spectroscopy

Canadian Journal of Physics, 1986
Detection of ferromagnetic resonance (FMR) by photothermal beam deflection has been used to study the spatial inhomogeneity of magnetic properties. The technique has been applied to measure the depth dependence of FMR in layered recorder tapes and to determine the lateral variation of the demagnetizing field in metal–glass ribbons.
U. Netzelmann   +3 more
openaire   +1 more source

New development of sensitive magnetic sensors for nondestructive evaluation of structural materials

SPIE Proceedings, 2005
The diagnosis of iron-based materials was performed by using many magnetic sensors such as a small Hall element for leakage flux observations after polarizations, a locally sensitive fluxgate sensor available down to 100pT, by a pick-up coil for magnetic noise observation and by a triple-fold coil for eddy current detector.
Koji Yamada   +4 more
openaire   +1 more source

Carburization depth evaluation from magnetic nondestructive testing

NDT & E International, 2023
Benjamin Ducharne   +7 more
openaire   +1 more source

Advanced Quantitative Magnetic Nondestructive Evaluation Methods — Theory and Experiment

1979
The scale of fatigue crack phenomena is reviewed in relation to the size detection capabilities of nondestructive evaluation methods. Several features of the fatigue phenomena which should be considered in developing nondestructive characteriziation methods are tabulated and briefly discussed. A qualitative assessment of such factors in relation to the
J. R. Barton   +3 more
openaire   +1 more source

Carbon Nanotube Based Magnetic Tunnel Junctions for Electromagnetic Nondestructive Evaluation

MRS Proceedings, 2002
AbstractSpin coherent transport in carbon nanotubes enables single-nanotube devices for magnetic field sensing. This unique transport property of single walled carbon nanotubes (SWCNTs) has been studied for development into advanced sensors for nondestructive evaluation (NDE).
Buzz Wincheski   +3 more
openaire   +1 more source

Nondestructive Evaluation of Irradiation Embrittlement of SQV2A Steel by Using Magnetic Method

AIP Conference Proceedings, 2006
Irradiation embrittlement of SQV2A steel was evaluated by magnetic methods. Thermal aging (TA) and electron irradiation (EI) specimens were prepared to evaluate the thermal aging and the irradiation damage effects separately. B‐H loops changed with TA and EI.
openaire   +1 more source

Numerical Consideration of Magnetic Camera for Quantitative Nondestructive Evaluation

Key Engineering Materials, 2004
Jin Yi Lee, Do Won Seo, Tetsuo Shoji
openaire   +1 more source

Home - About - Disclaimer - Privacy