Results 161 to 170 of about 1,244 (195)
Some of the next articles are maybe not open access.

Spectroscopy on a modulated magneto-optical trap

Optics Letters, 1998
We demonstrate a new type of high-resolution two-photon frequency modulation (FM) spectroscopy with cold atoms in a magneto-optical trap. Instead of modulating the probe as in ordinary FM spectroscopy, we modulate the trap itself by FM of the trapping beams.
Sørensen, Jens Lykke   +2 more
openaire   +3 more sources

A magneto-optical trap for radioactive atoms

SPIE Proceedings, 2013
This paper presents the recent results of the TrapRad/Francium collaboration whose final aim is the measurement of the Atomic Parity Non-Conservation effect (APNC) in Francium atoms stored in a Magneto – Optical Trap (MOT) built at the Laboratori Nazionali di Legnaro (LNL) of the National Institute for Nuclear Physics (INFN).
E. Mariotti   +10 more
openaire   +3 more sources

Circular Magneto-Optical Trap for Neutral Atoms [PDF]

open access: yesJournal of the Physical Society of Japan, 2008
We propose and experimentally demonstrate a novel scheme to magneto-optically trap neutral atoms in a ring shaped trap that can be used to transfer atoms into a circular magnetic trap with high density. This inturn enables to evaporatively cool atoms and study the behaviour of ultra cold gases in a periodic 2-dimensional potential. The circular magneto-
Makoto Morinaga
exaly   +3 more sources

Magneto-Optical Trap of Cadmium

International Conference on Quantum Information, 2007
We achieve the first magneto-optical trap of Cadmium. When integrated with a nearby ion trap, this allows for the possibility of protecting quantum information from environment perturbations via charge neutralization of trapped ions.
M.-S. Chang   +7 more
openaire   +1 more source

Trapping of Radioactive Atoms: the Legnaro Francium Magneto-Optical Trap

Physica Scripta, 2003
Experiments aimed at laser cooling and trapping of radioactive atoms are nowadays operational at several laboratories. They open up a bridge between atomic and nuclear physics, allowing new precise spectroscopic measurements and detailed analysis of nuclear decay processes.
ATUTOV, S. N.   +14 more
openaire   +5 more sources

The Blue-Detuned Magneto-Optical Trap

2017
It has been more than 30 years since the first demonstration of a magneto-optical trap (MOT) using sodium atoms. Since then the MOT has revolutionised the field of atomic physics by facilitating the emergence of a broad range of productive avenues of research using atoms prepared at low temperatures and high densities.
openaire   +2 more sources

Magneto-optical trapping of Fermionic potassium atoms

Physical Review A, 1998
We have trapped ${}^{40}\mathrm{K}$ in a vapor-cell magneto-optical trap starting from a natural abundance sample. This rare, weakly radioactive atom is a fermion. The number of trapped atoms is approximately 8000, with a density of $\ensuremath{\sim}{10}^{8}$ atoms/${\mathrm{cm}}^{3}$.
CATALIOTTI, FRANCESCO SAVERIO   +7 more
openaire   +2 more sources

Observation of a single atom in a magneto-optical trap

Optics Letters, 1994
Fluorescence from Cs atoms in a magneto-optical trap is detected under conditions of very low atomic density. Discrete steps are observed in the fluorescent signal versus time and are associated with the arrival and departure of individual trapped atoms.
Z, Hu, H J, Kimble
openaire   +2 more sources

Spatial distribution of atoms in a magneto-optical trap

Physical Review A, 1993
We present a theoretical analysis to explain the origin of different spatial distributions of laser-cooled sodium atoms in a magneto-optical trap. Such distributions, which include spherical clouds, rings, and rings with cores, are attributed to the radiation pressure due to misaligned Gaussian beams acting on each individual atom.
, Bagnato   +5 more
openaire   +2 more sources

Improved magneto-optic trapping in a vapor cell

Optics Letters, 1992
We have captured 3.6 x 10(10) cesium atoms in a magneto-optic trap loaded from a vapor cell. The 300-fold increase in the number of trapped atoms compared with that of previous research was accomplished by using larger laser intensities and 4-cm-diameter laser beams. The loading time constant was as short as 0.2 s.
K E, Gibble, S, Kasapi, S, Chu
openaire   +2 more sources

Home - About - Disclaimer - Privacy