Results 221 to 230 of about 13,029,295 (332)
An in situ electroplating approach for MEX 3D printing is proposed, enabling copper deposition during the fabrication of conductive polymers. The method combines a printer‐integrated plating head, ML‐based g‐code control, and stop‐and‐go printing, achieving near‐bulk copper conductivity and enabling fully embedded, assembly‐free electronic components ...
Gianluca Percoco +5 more
wiley +1 more source
CFD Mechanistic Modeling of a Monolithic Chromatography System: Challenges and Opportunities. [PDF]
Coimbra JC +4 more
europepmc +1 more source
A Pressure Microsensor Made of Parylene‐C for Use as Medical Implant
A monolithic parylene‐C pressure sensor with gold strain gauges provides 6.2 μV$\mu{\rm V}$·mmHg$\cdot{\rm mmHg}$−1$^{-1}$ sensitivity. The morphology of a sputtered thin film strain sensor is granular/columnar, which results in a high gauge factor of 7.5. Thermal bonding and parylene‐C coating create a hermetic cavity.
Ann‐Kathrin Klein +2 more
wiley +1 more source
Optimizing biometric system selection via complex spherical fuzzy einstein aggregation operators. [PDF]
Kanwal S +3 more
europepmc +1 more source
ABSTRACT Quantifying oral polymorphonuclear neutrophils (oPMNs) is a clinically validated approach for assessing periodontal inflammation. However, current methods, such as manual hemocytometry and flow cytometry, are time‐consuming (>3 h), require invasive sampling, and depend on staining and complex instrumentation, making them unsuitable for point ...
Mohsen Hassani +9 more
wiley +1 more source
Age-structured mechanical models for tumor growth. [PDF]
Levy D, Lim H, Mellet A, Wildes M.
europepmc +1 more source
Liquid metal additives are processed in elastomer host resulting in highly conductive and stretchable composites. The material functions as a piezoresistive sensor with minimal drift, low stiffness, and enhanced operating range. The film can replace wires to charge a mobile phone at ∼350% strain and monitors bodily motion in real‐time via a portable ...
Patryk Wojciak +3 more
wiley +1 more source
Comparative Analysis of the Application of Five-, Seven- and Nine-Roll Sheet Straightening Using Numerical Tools. [PDF]
Stradomski G +5 more
europepmc +1 more source
A stress‐normalised sensitivity metric (S = G/Y) is introduced as a materials‐level benchmark for intrinsically piezoresistive nanocomposites. By decoupling electromechanical response (G) from stiffness (Y), the framework enables direct comparison across diverse systems and clarifies design trade‐offs for wearable sensors.
Conor S. Boland
wiley +1 more source
This study shows that a lightweight blackbox neural network provides a practical, cost‐effective solution for bidirectional process prediction in laser‐induced graphene (LIG) fabrication. Achieving high predictive performance with minimal overhead, the approach democratizes machine learning (ML) for resource‐limited environments.
Maxim Polomoshnov +3 more
wiley +1 more source