Results 61 to 70 of about 2,366,283 (219)

Porous, rigid metal(III)-carboxylate metal-organic frameworks for the delivery of nitric oxide [PDF]

open access: yes, 2014
This work was supported by CNRS, EU through the ERC-2007-209241-BioMOFs ERC grant (J.F.E., P.H., C.S.). R.E.M. thanks the GEMI Fund and the E.P.S.R.C for funding.
Christian Serre   +29 more
core   +1 more source

Abnormal Expansion Along the Synthesis of Zinc Stannate: A Way for Porous Ceramics Without Addition of Pore Generators

open access: yesJournal of the American Ceramic Society, Volume 109, Issue 2, February 2026.
The abnormal expansion associated with the simultaneous synthesis and sintering of Zn2SnO4 from ZnO and SnO2 is due to the reaction mechanism and correlated with the conversion. This phenomenon opens the way to manufacture porous ceramics without the addition of pore generators, simplifying the process, and especially the thermal treatment.
María José Orts   +3 more
wiley   +1 more source

A novel embedded voltage‐clamped circuit for multilevel modular converters submodule to suppress very fast transient overvoltage

open access: yesHigh Voltage
The submodule in multilevel modular converters experiences a very fast transient overvoltage (VFTO) during switch operation of gas‐insulated switchgear, which also results in overvoltage on power devices, such as thyristors and insulated gate bipolar ...
Hong Shen   +7 more
doaj   +1 more source

An intelligent protection scheme for series-compensated transmission lines connecting large-scale wind farms

open access: yesFrontiers in Energy Research, 2023
Series-compensated transmission lines (SCTLs) are increasingly preferred for transmitting bulk amounts of electricity generated from the present-day large-scale wind farm to the utility grid due to several technical and economic benefits. However, when a
M. S. Prabhu   +4 more
doaj   +1 more source

Computational Model and Experimental Validation of the Influence of Grain‐Boundary Parameters on the Electrical Performance of Arrester Varistor

open access: yesInternational Journal of Ceramic Engineering &Science, Volume 8, Issue 1, January 2026.
This paper presents a calculation model for the nonlinear characteristics of varistors based on a basic conductive mechanism, and it has been verified through experiments. The mechanism of the barrier's effect on electrical performance has been obtained.
Zhengzheng Fu   +7 more
wiley   +1 more source

Comparative Assessment of Lightning Overvoltages at Transformer and Hydrogenerator Terminals Under Nonideal Station‐Side Metal‐Oxide Arrester Conditions

open access: yesIET Electric Power Applications, Volume 20, Issue 1, January/December 2026.
This study comparatively assesses lightning‐overvoltage propagation to the transformer high‐voltage terminal and hydrogenerator busbar of a hydropower plant under prescribed lightning‐current injection and selected nonideal conditions of a station‐side metal‐oxide arrester.
Jiachen Zhang   +9 more
wiley   +1 more source

Study on the Unipolar Impulse Aging Characteristics of ZnO Varistors and Their Condition Monitoring Methods

open access: yesApplied Sciences
Metal-oxide surge arresters (MOSAs) are critical devices for overvoltage protection in power systems, and the aging characteristics of their zinc oxide (ZnO) varistors under impulse and power-frequency voltages exhibit significant differences.
Yongqiang Fan   +7 more
doaj   +1 more source

Accurate Fault Current Phasor Estimation in Series‐Compensated Transmission Lines Using Improved Particle Swarm Optimisation

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
A new evolutionary search algorithm based on improved Particle Swarm Optimisation (PSO) is introduced in this study to estimate the phasor. The performance has been evaluated through extensive simulations considering transient components, harmonics, and frequency changes in noiseless and noisy conditions.
Seyedeh Mina Abed Shiadeh   +2 more
wiley   +1 more source

Determining the effect of bismuth oxide on the microstructure and electrical response of cold‐sintered ZnO varistors

open access: yesJournal of the American Ceramic Society, Volume 109, Issue 1, January 2026.
Abstract Microstructure homogeneity and grain size reduction are needed to ensure the current uniformity and reliability required in metal oxide varistors for DC circuit breakers. Cold sintering (CS)–a low‐temperature digestive liquid and high‐pressure densification process–has previously shown reduced grain growth, but it is not clear how the lower ...
Kayla Y. Chuong   +5 more
wiley   +1 more source

Performance comparison between Metal Oxide Varistor and Gas Discharge Tube against transient overvoltage due to lightning strike: article [PDF]

open access: yes, 2014
This project presents the comparison of the performance protection devices of transient overvoltage due to lightning strike. There were two protection devices compared in this project which is Metal Oxide Varistor (MOV) and Gas Discharge Tube (GDT ...
Johari, Dalina, Ajut, Lawrence
core  

Home - About - Disclaimer - Privacy