Results 141 to 150 of about 1,107 (169)
Some of the next articles are maybe not open access.
Micellar electrokinetic chromatography of proteins
Journal of Chromatography A, 1997Abstract Micellar electrokinetic capillary chromatography (MECC) of proteins is a high resolution capillary electrophoretic (CE) analysis method that utilizes the hydrophobic and electrostatic interaction of protein analytes with surfactant micelles present in the buffer medium to facilitate separation. Through the manipulation of the protein-micelle
Mark A. Strege, Avinash L. Lagu
openaire +1 more source
Journal of Pharmaceutical and Biomedical Analysis, 2001
Micellar electrokinetic chromatography (nMEKC) method was applied to the determination of the partition behaviour between water and micelle for a group of antibiotics using sodium dodecyl sulphate (SDS) as an anionic model surfactant. In the method, the running buffer contains both the micelles and the drug, and the injected solution contains the same ...
Y, Mrestani, Z, Marestani, R H, Neubert
openaire +2 more sources
Micellar electrokinetic chromatography (nMEKC) method was applied to the determination of the partition behaviour between water and micelle for a group of antibiotics using sodium dodecyl sulphate (SDS) as an anionic model surfactant. In the method, the running buffer contains both the micelles and the drug, and the injected solution contains the same ...
Y, Mrestani, Z, Marestani, R H, Neubert
openaire +2 more sources
Separation of fungicides by micellar electrokinetic capillary chromatography
ELECTROPHORESIS, 1997AbstractCapillary electrophoresis with ultraviolet detection (CE/UV) of selected fungicides (carbendazim, metalaxyl, propiconazole, and vinclozolin) using different buffer compositions was investigated. Capillary zone electrophoresis (CZE) with 10 mM sodium phosphate (pH 7.0) was not useful in separating the four fungicides used in this study. However,
K V, Penmetsa, R B, Leidy, D, Shea
openaire +2 more sources
Analysis of arylamine isomers by micellar electrokinetic chromatography
ELECTROPHORESIS, 2002Analysis of carcinogenic substances is a high-priority area. Carcinogenic arylamines draw the analyst's attention because dyes and pigments are in production and used in large volumes. Identification of carcinogenic isomers of arylamines employing micellar electrokinetic chromatography (MEKC), a mode of capillary electrophoresis was studied as it ...
Rama Jeevan Ganesh, Jeevan +3 more
openaire +2 more sources
Application of micellar electrokinetic chromatography to pharmaceutical analysis
ELECTROPHORESIS, 1990AbstractElectrokinetic chromatography is a new type of analytical separation method which belongs to the group of high performance capillary electrophoretic techniques but whose separation principle is based on that of chromatography. The solute distributes itself between a carrier and the surrounding medium.
H, Nishi, S, Terabe
openaire +2 more sources
Analysis of prostaglandins by micellar electrokinetic capillary chromatography
Journal of Chromatography A, 1997This paper presents a rapid and reliable micellar electrokinetic capillary chromatography (MEKC) method to separate major prostaglandins and thromboxane B2. The running buffer was modified with sodium dodecyl sulfate (SDS). The effects of the SDS concentration on the migration behavior of analytes was also examined.
Y Z, Hsieh, K L, Kuo
openaire +2 more sources
[14] Micellar electrokinetic chromatography
1996Publisher Summary Terabe et al. first demonstrated the use and principle of micellar electrokinetic chromatography (MEKC) based on the suggestion made by Nakagawa. Since then, diverse applications of this method to various organic compounds have been reported.
Norio Matsubara, Shigeru Terabe
openaire +1 more source
Optimization of micellar electrokinetic chromatography
Analytical Chemistry, 1990surfactant concentratlon to use. Another equatlon Is dedved that relates the analysts time to flve parameters: R,, a (rdectlvlty), & r, fJfm, and H/v, (plate helght/electroo#notlc vdoclty). The capacity factor for the best tusddbn k glven by k = (fJfo)1'2, where 1, and I, are the retentbn times of the aqueous and mlceHar phases, respectively.
openaire +1 more source
The use of mixed surfactants in micellar electrokinetic chromatography
ELECTROPHORESIS, 1994AbstractThe use of mixed surfactants for the separation of nine phenylthiohydantoin amino acids (PTH amino acids) by micellar electrokinetic chromatography (MEKC) was examined. The potential of a mixed surfactant system, consisting of cationic and anionic surfactants, for enhancing the selectivity of MEKC separations was explored.
C P, Ong, C L, Ng, H K, Lee, S F, Li
openaire +2 more sources
Chiral Micellar Electrokinetic Chromatography
2004Koji, Otsuka, Shigeru, Terabe
openaire +2 more sources

