Results 71 to 80 of about 7,517 (215)

Revolutionization of the Leadless Pacemaker Implantation: Hemodynamic Verification Slashes Vascular Complications

open access: yesReviews in Cardiovascular Medicine
Background: The procedure of implanting a Micra leadless pacemaker (Medtronic PLC, Dublin, Ireland) via transfemoral venous access carries the risk of vascular complications.
Xin Zhang   +3 more
doaj   +1 more source

Impact of Leadless Pacemaker Implantation Position on Subclinical Right Ventricular Perforation

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Introduction Leadless pacemakers are typically implanted in the mid‐septum of the right ventricle (RV) to mitigate the risk of perforation. However, reports on the precise location of these implants are limited. This study aimed to elucidate tine‐based leadless pacemaker position and presence of subclinical RV perforation through computed ...
Young Shin Lee   +16 more
wiley   +1 more source

Jugular Versus Femoral Venous Access for Leadless Pacemaker Implantation: A Systematic Review and Meta‐Analysis

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Background Leadless pacemakers (LPMs) have been shown to reduce complications compared with conventional transvenous pacing. Transfemoral venous access (FA) is the standard implantation approach; however, the transjugular approach (JA) has recently emerged as an alternative strategy, but comparative evidence remains limited.
Federico Giannino   +11 more
wiley   +1 more source

Point-of-Care Electrochemical Diagnostic Developments for Multidrug-Resistant Bacteria: Role of Aptamers and Nanomaterials

open access: yesBiosensors
The unchecked and uncontrolled global spread of multidrug-resistant (MDR) bacteria is a serious challenge to healthcare and modern medicine, and demands diagnostic approaches that are rapid, sensitive, multiplexed, and reliable in point-of-care (POC ...
Kamna Ravi, Baljit Singh
doaj   +1 more source

Leadless Pacemaker Implantation in High‐Risk Patients: Real‐World Outcomes From a Multicenter Israeli Registry

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Introduction Transvenous pacemakers are effective but carry significant short‐ and long‐term complications. Leadless pacemakers were developed to overcome these limitations, however, data in high‐risk patients ineligible for transvenous systems remain limited.
Moshe Katz   +7 more
wiley   +1 more source

Clinical characteristics of bloodstream infection by Parvimonas micra: retrospective case series and literature review

open access: yesBMC Infectious Diseases, 2020
Background Gram-positive anaerobic (GPA) bacteria inhabit different parts of the human body as commensals but can also cause bacteremia. In this retrospective observational study, we analyzed GPA bacteremia pathogens before (2013–2015) and after (2016 ...
Tsuyoshi Watanabe   +5 more
doaj   +1 more source

Management of Congenital Complete Atrioventricular Block in Preterm Neonates With Novel Pacing Method

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Congenital complete atrioventricular block (CCAVB) is a rare autoimmune mediated disorder with a guarded prognosis, particularly when associated with extreme prematurity and severe bradycardia. Recent advances in neonatal care for extremely premature infants with delivery at level IV neonatal intensive care unit and novel pediatric pacing ...
Anusha Bai Kalithkar   +5 more
wiley   +1 more source

ADVANTAGES OF MICRA(tm) PACEMAKER

open access: yes, 2020
Elektrostimulator je uređaj koji omogućuje uspostavljanje pravilnog srčanog ritma. U evoluciji razvoja uređaja za elektrostimulaciju srca pojavio se novi uređaj, MICRAtm elektrostimulator srca.
Labaš, Vedrana
core   +1 more source

Late Extraction of Micra AV and Implantation of Right Atrial Leadless Pacemaker

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Background Tine‐based leadless pacemakers have been commercially implanted over the last 10 years. Retrieval of older devices is rarely discussed and based on rare case reports only. Methods A retrospective review of an extraction case of a Micra AV leadless pacemaker was performed. Internal Review Board approval was obtained.
Lydia Fekadu Messele   +3 more
wiley   +1 more source

A Reassessment of Prophylactic Antibiotics in Low‐Infection‐Risk Electrophysiology Procedures

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Certain electrophysiology (EP) procedures are associated with minimal tissue disruption and do not involve permanent transvenous leads. As a result, these interventions carry a lower risk of device‐ or procedure‐related infection. These procedures include placement of implantable cardiac monitors, leadless pacemakers, and left atrial appendage
Rahel M. Sileshi   +14 more
wiley   +1 more source

Home - About - Disclaimer - Privacy