Results 81 to 90 of about 146,973 (259)

Comparison between defects and micro-notches in multiaxial fatigue – The size effect and the gradient effect [PDF]

open access: yes, 2009
Lien vers la version éditeur: http://www.sciencedirect.com/science/article/pii/S0142112308002156This paper attempts to improve the understanding of the multiaxial high cycle fatigue response of micro sized stress concentrations or notches of different ...
MOREL, Franck, NADOT, Yves, MOREL, Anne
core   +1 more source

Unveiling the Microvasculature: The Index of Microcirculatory Resistance and Its Expanding Role in Cardiovascular Care

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Index of microcirculatory resistance (IMR) is a cutting‐edge, wire‐based tool that advances the capability assessment of coronary microvascular function. By utilizing distal coronary pressure and mean transit time under maximal hyperemia, IMR delivers consistent, reproducible insights into the microvasculature's dynamic health.
Joanna Sohn   +10 more
wiley   +1 more source

Investigation into the selection of viewing configurations for three-component planar Doppler velocimetry measurements. [PDF]

open access: yes, 2007
A method for the calculation of three orthogonal velocity components in planar Doppler velocimetry (PDV) using four or more measured velocity components (to the three typically used) is presented.
Nobes, David S.   +2 more
core  

Review of CFD modelling techniques for single‐phase and multiphase flow in static mixers

open access: yesThe Canadian Journal of Chemical Engineering, EarlyView.
This review synthesizes computational fluid dynamics (CFD) approaches for static mixers, linking hydrodynamics to pressure drop, particle/droplet distributions, mixing metrics, and heat‐transfer performance to guide modelling choices and design decisions. Abstract Static mixers enable compact and low‐energy intensification.
Jussan Jaeger   +7 more
wiley   +1 more source

Informed acceptance and perceptions of the 2025 ILAE seizure classification following structured teaching

open access: yesEpileptic Disorders, EarlyView.
Abstract Objective To assess informed acceptance and perceptions of the 2025 update of the International League Against Epilepsy (ILAE) seizure classification—after participants had received a focused educational introduction to the updated classification. Methods We analyzed anonymized live poll responses from two educational webinars dedicated to the
Sándor Beniczky   +6 more
wiley   +1 more source

Micro-motion feature extraction of space targets based on sinusoidal frequency modulation Fourier transform

open access: yesThe Journal of Engineering, 2019
The space target can be discriminated from other objects by the micro-motion feature difference. The micro-motion features of a space target with precession include the spinning period, the precession angle and the precession period etc. The main work of
Jian Hu   +4 more
doaj   +1 more source

Radar target micro-doppler signature classification

open access: yes, 2008
This thesis reports on research into the field of Micro-Doppler Signature (μ-DS) based radar Automatic Target Recognition (ATR) with additional contributions to general radar ATR methodology.
Smith, G.E.
core  

Flexible wearable electronics for cardiovascular monitoring from surface signals to deep physiological insights

open access: yesFlexMat, EarlyView.
This review organizes flexible wearable electronics for cardiovascular monitoring into four interconnected information layers: surface electrophysiology, hemodynamic sensing, vascular imaging, and biofluid biomarker analysis. This framework clarifies how electrical rhythm, vascular loading, structural and flow‐related features, and biochemical states ...
Qiao Chen   +5 more
wiley   +1 more source

Research progress on the use of the optical coherence tomography system for the diagnosis and treatment of central nervous system tumors

open access: yesIbrain, Volume 11, Issue 1, Page 3-18, Spring 2025.
With the advantages of high‐resolution imaging, efficient image acquisition, intraoperative real‐time detection, and radiation‐free and noninvasive characteristics, optical coherence tomography (OCT) provides accurate diagnosis and effective intraoperative guidance for the minimally invasive diagnosis and treatment of central nervous system (CNS ...
Jiuhong Li   +10 more
wiley   +1 more source

Perceptions and experiences of midwives' regarding the use of the labor care guide at two state hospitals in Khomas region, Namibia

open access: yesInternational Journal of Gynecology &Obstetrics, EarlyView.
Abstract The labor care guide (LCG) is a new tool for monitoring labor, introduced to replace the partograph, which had been used improperly and inconsistently across various contexts. Early research suggests that healthcare practitioners view the LCG as a tool that enhances the quality of care during labor and delivery.
Amalia N. N. Ilonga   +1 more
wiley   +1 more source

Home - About - Disclaimer - Privacy