Results 41 to 50 of about 179,844 (314)
Eletrodo modificado com surfactante zwiteriônico para detecção de antioxidantes [PDF]
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas, Programa de Pós-Graduação em Química, Florianópolis, 2014.Neste trabalho, a superfície de um eletrodo de carbono vítreo foi modificada com filmes ...
Silva, Cristiano Pochmann da
core
A Depolarizing Leak in Sodium Bicarbonate Cotransporter NBCe1 Causes Brain Edema
ABSTRACT Objectives SLC4A4 encodes electrogenic sodium bicarbonate cotransporter NBCe1, prominently expressed in kidney and brain. Recessive loss‐of‐function variants in SLC4A4 cause proximal renal tubular acidosis, no brain edema. In the brain, NBCe1 is expressed by astrocytes, where it regulates pH and mediates astrocyte volume changes.
Quinty Bisseling +16 more
wiley +1 more source
ABSTRACT Objective Variants in SLC6A1, encoding the GABA transporter 1 (GAT‐1), cause epilepsy, autism spectrum disorder, and developmental delay via loss of GABA uptake, impaired trafficking, and ER retention. We previously found that 4‐Phenylbutyrate (PBA), an FDA‐approved drug, restores GABA uptake and reduces seizures in SLC6A1‐related disorders ...
Melissa B. DeLeeuw +5 more
wiley +1 more source
A novel chemically modified electrode based on polyaniline/titanium carbide nanoparticles (PANI/nano-TiC) was developed by electrochemically co-polymerization of aniline and nano-TiC.
Zhencui Su +5 more
doaj +1 more source
Chemically modified electrodes for electrocatalysis
Abstract At a modified electrode, electrocatalysis is accomplished by an immobilized redox substance acting as an electron transfer mediator between the electrode and a reaction substrate. Such mediated electrocatalysis is possible with monomolecular and multimolecular layers of the redox substance. The electron transfer mediation can
openaire +2 more sources
This study presents a reversible temperature sensor with high switching ratio, ∼103. The device is fabricated using PET‐ITO and carbon nanotube dispersions in alkane. Considering its application in cold chain logistics, a proof‐of‐concept with LED is showcased. Thus, a temperature drop below the threshold temperature (crystallization temperature of the
Sunil Kumar Behera +8 more
wiley +1 more source
Electrochemical Behavior and the Detection Limit of Ascorbic Acid on a Pt Modified Electrode
The electrochemical behavior of ascorbic acid (AA) at the DL-Alanine (DL-Ala) polymer film modified platinum electrode (DL-Ala/Pt electrode) had been studied by using cyclic voltammetry.
H.M. Rageh +3 more
doaj +1 more source
Electrochemical Analysis of Tryptophan using a Nanostructuring Electrode with Multi-walled Carbon Nanotubes and Cetyltrimethylammonium bromide Nanocomposite [PDF]
Multi-walled carbon nanotubes (MWCNTs) were immobilized on the surface of a glassy carbon electrode (GCE) in the presence of cetyltrimethylammonium bromide (CTAB) to form a MWCNTs-CTAB nanocomposite-modified electrode.
Ghasem Karim-Nezhad +3 more
doaj +1 more source
The corrosion performance of AlSi7Mg and AlSi10Mg alloys produced through selective laser melting (SLM) was examined under compressive stress in a chloride environment. Electrochemical analyses, including open‐circuit potential (OCP), potentiodynamic polarization (CPP), and electrochemical impedance spectroscopy (EIS), were complemented by scanning ...
Femi John Akinfolarin +2 more
wiley +1 more source
Imprinted Zeolite Modified Carbon Paste Electrode as A Selective Potentiometric Sensor for Blood Glucose [PDF]
Imprinted zeolite modified carbon paste electrode as a potentiometric sensor for glucose analysis in blood serum sample has been developed. In this study, the type of used zeolite was TS-1.
Herwin Predianto, .- +5 more
core

