Results 51 to 60 of about 28,234 (242)
Abstract Objective To assess the feasibility, technical performance, and safety of a novel endovascular electroencephalogram (eEEG) electrode, EP‐01, designed for minimally invasive seizure localization in patients with drug‐resistant epilepsy. Methods This single‐center, prospective, exploratory trial enrolled five patients with drug‐resistant ...
Kota Araki +9 more
wiley +1 more source
Abstract Objectives The study aimed to assess the feasibility of recording electrically evoked compound action potentials (ECAPs) from the rat spinal cord. To achieve this, we characterized electrophysiological responses of dorsal column (DC) axons from electrical stimulation and quantified the relationship between ECAP and motor thresholds (ECAPTs and
Birte Elisabeth Dietz +3 more
wiley +1 more source
Epilepsy surgery: From bench to the clinics
Abstract Objective Recent advances in epilepsy surgery in patients with intractable epilepsy make it possible to study the mechanism of epilepsy in human brains. However, the true extent and propagation of each epileptogenic area from the epileptogenic focus in each patient is still difficult to perform “epilepsy cure” by surgery.
Tatsuya Tanaka
wiley +1 more source
Abstract Objective To evaluate the effects of bilateral caudal zona incerta (cZi) deep brain stimulation (DBS) for Parkinson's disease (PD) one year after surgery and to create anatomical improvement maps based on patient‐specific simulation of the electric field.
Rasmus Stenmark Persson +6 more
wiley +1 more source
ABSTRACT Background The robotic‐assisted extended “Sistrunk” approach (RESA) is a minimally invasive technique providing access to hypopharyngeal and laryngeal structures via a submental incision and vallecular pharyngotomy, bypassing the base of tongue.
Bartosz Wojtera +5 more
wiley +1 more source
ABSTRACT Background Following promising initial results of the robotic‐assisted extended “Sistrunk” approach (RESA) that uses a submental incision to hypopharyngeal and laryngeal tumors, bypassing the base of tongue, we report its further development: submental approach robotic‐assisted neck dissection (SARAND), intended to enable bilateral neck ...
Bartosz P. Wojtera +5 more
wiley +1 more source
High‐Throughput Quantitative Chemical Shift‐Encoded MRI of the Liver
ABSTRACT Background Access to MRI is limited by lengthy exam times and inefficient utilization. Focused protocols can reduce exam times, but workflow variability and inefficient room turnaround contribute to conservative scheduling with long exam slots.
Garrett C. Fullerton +10 more
wiley +1 more source
Complicaciones asociadas con la histeroscopia
Objetivo: describir las complicaciones más frecuentes en la histeroscopia comparando las técnicas mediante energía monopolar y la bipolar. Metodología: búsqueda en las bases de datos ELSEVIER, EBSCO, NCBI, SCIENCEDIRECT, SciELO y PUBMED/MEDLINE ...
Nathalia Andrea Cerón +3 more
doaj +1 more source
Diffusion MRI of the Body: Beyond PGSE‐EPI
ABSTRACT Diffusion magnetic resonance imaging (dMRI) is a widely used clinical imaging technique which is sensitive to changes in tissue microstructure including cellularity, perfusion, and tissue damage. DMRI has been used in whole‐body imaging as well as in targeted imaging of every major anatomical region.
Matthew T. Cherukara +6 more
wiley +1 more source
A Novel In Vitro Sensing Configuration for Retinal Physiology Analysis of a Sub-Retinal Prosthesis
This paper presents a novel sensing configuration for retinal physiology analysis, using two microelectrode arrays (MEAs). In order to investigate an optimized stimulation protocol for a sub-retinal prosthesis, retinal photoreceptor cells are stimulated,
Kyung Hwan Kim +6 more
doaj +1 more source

