Results 191 to 200 of about 882,801 (311)

Topological Photonic Devices and Circuits at Terahertz Frequencies

open access: yesLaser &Photonics Reviews, EarlyView.
This review examines how 3D topological insulators and emerging topological photonic phases enable robust, low‐loss and defect‐immune terahertz devices. Fundamental properties, device implementations and topological transport mechanisms are surveyed, revealing new opportunities for reconfigurable, high‐performance THz components and scalable ...
Samane Kalhor   +3 more
wiley   +1 more source

Ambiguities in Assigning Single‐Crystal NMR Data to Individual Atoms in the Crystal Structure: A Case Study of Hambergite, Be2$$ {}_2 $$BO3$$ {}_3 $$OH, by 9Be and 11B NMR Spectroscopy, XRD Measurements and DFT Calculations

open access: yesMagnetic Resonance in Chemistry, EarlyView.
The fundamental question of how to assign NMR resonances to specific atoms in the unit cell is addressed by using the 9Be and 11B spectra of the natural mineral hambergite as a model system. ABSTRACT The NMR interaction tensors of 9Be and 11B of hambergite, Be2$$ {}_2 $$BO3$$ {}_3 $$OH, were derived from single‐crystal NMR experiments.
Jennifer Steinadler   +6 more
wiley   +1 more source

Narrow Linewidth Distributed Bragg Reflectors Based on InGaN/GaN Laser. [PDF]

open access: yesMicromachines (Basel), 2019
Xie W   +5 more
europepmc   +1 more source

Simultaneous Detection of GABA and Glycine Using MEGA‐PRESS With TE Optimization at 3T

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To achieve the simultaneous acquisition of gamma‐aminobutyric acid (GABA) and glycine (Gly) using a MEGA‐PRESS sequence with an optimized TE at 3T. Methods MEGA‐PRESS simulations were performed at TEs 60‐88 ms to determine the optimal TE for Gly detection with minimal myo‐Inositol (mI) overlap and maximal GABA detection sensitivity ...
Justin R. Singer, Kimberly L. Chan
wiley   +1 more source

Study on Linewidth and Phase Noise Characteristics of a Narrow Linewidth External Cavity Diode Laser. [PDF]

open access: yesSensors (Basel)
Hu S   +10 more
europepmc   +1 more source

Postexercise Lactate Clearance, T2 Relaxation, and J‐Modulation in Human Skeletal Muscle Measured With Double‐Quantum Filtered 1H MRS at 7 T

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose 1H MRS lactate measurements are potentially valuable for studying energy metabolism in working skeletal muscle, but some technical obstacles need to be overcome. Spectral filtering to isolate the lactate signal from overlapping lipid resonances shows promise.
Kostiantyn Repnin   +6 more
wiley   +1 more source

Efficient, high-power, narrow-linewidth, continuous-wave quantum-dot semiconductor comb laser. [PDF]

open access: yesSci Rep
Buyalo M   +5 more
europepmc   +1 more source

Dynamics of Purification in Cu2O

open access: yesphysica status solidi (b), EarlyView.
Rydberg excitons in Cu2O have been shown to be highly efficient in neutralizing and screening charged impurities, which is referred to as purification. In this manuscript, the dynamics of the purification process are investigated under varying probe exciton‐ and plasma density. The transient absorption of Rydberg excitons is analyzed and five different
Binodbihari Panda   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy