Results 31 to 40 of about 12,500,295 (288)
The impact of internal asymmetry of induction motors on the supply network
This paper presents the impact of internal asymmetry in induction motors, such as short circuits, close circuits, stator impedance differences and rotor damage, on the supply network in the form of negative and zero-sequence currents, illustrating the ...
Janusz Petryna +3 more
doaj +1 more source
Detection of Internal Faults in Transformers By Negative Sequence Current
Initially it is very difficult to find out internal fault in transformer. These internal fault are hazardous and causes overheating of transformer oil and winding, it consequences as insulation failure because of this uninterrupted power supply cannot be continued. It is more difficult to detect internal fault in small ratting transformer.
Satyam Prakash, Vivek Mishra
openaire +1 more source
prot4EST: translating expressed sequence tags from neglected genomes [PDF]
The genomes of an increasing number of species are being investigated through generation of expressed sequence tags (ESTs). However, ESTs are prone to sequencing errors and typically define incomplete transcripts, making downstream annotation difficult ...
Mark L Blaxter +3 more
core +1 more source
To explore the clustered voltage balancing mechanism of the cascaded H-bridge static synchronous compensator (STATCOM), this paper analyzes the causes of unbalanced clustered voltage. The negative-sequence current caused by the compensation of unbalanced
Yu Jin +4 more
doaj +1 more source
Identification and location method of asymmetric faults in coal mine power network
Three asymmetrical faults of singe-phase grounding, singe-phase line breakage and ferroresonance in coal mine power network are easily misjudged, and existing methods hardly identify the three faults correctly.
WANG Qingliang, QIN Jie, LIU Xinru
doaj +1 more source
The doubly-fed induction generator (DFIG) is considered to provide a low-reactance path in the negative-sequence system and naturally comply with requirements on the negative-sequence reactive current in emerging grid codes.
Yuanzhu Chang +5 more
doaj +1 more source
A study on the negative sequence current injection during LVRT of IBRs
Low Voltage Ride Through (LVRT) behaviour of Inverter Based Resources (IBR) during asymmetrical grid faults is dictated by the requirements of Grid Code (GC) at the Point of Common Coupling (PCC) of the renewable energy plants. Earlier GCs demanded only positive sequence current injection, which gave freedom to inverter manufacturers to implement ...
A. Blázquez +5 more
openaire +1 more source
A computationally efficient current controller for simultaneous injection of both positive and negative sequences [PDF]
This work was supported by the Research Promotion Foundation (RPF, Cyprus, Project KOINA/SOLAR-ERA.NET/1215/06), by the Ministry of National Infrastructure Energy and Water (Israel) and the SOLAR-ERA.NET (European Union's Seventh Framework Programme). © 2017 IEEE. Personal use of this material is permitted.
Ali, Zunaib +3 more
openaire +1 more source
ABSTRACT Pediatric gastroenteropancreatic neuroendocrine neoplasms (GEP‐NENs) are extremely rare and clinically heterogeneous. Management has largely been extrapolated from adult practice. This European Standard Clinical Practice Guideline (ESCP), developed by the EXPeRT network in collaboration with adult NEN experts, provides (adult) evidence ...
Michaela Kuhlen +23 more
wiley +1 more source
Control Aspects of the Dynamic Negative Sequence Current Injection of Type 4 Wind Turbines
© 2014 IEEE. State-of-the-art distributed generation with a fully rated converter only injects positive sequence current into unbalanced faults. Recently, both publications and draft standards have suggested that the injection of negative sequence ...
Neumann, Tobias +3 more
core +1 more source