Results 1 to 10 of about 248 (101)

SAFIR-I: first NEMA NU 4-2008-based performance characterization [PDF]

open access: yesEJNMMI Physics, 2023
Background Small Animal Fast Insert for MRI detector I (SAFIR-I) is a novel Positron Emission Tomography insert for a $$7\,\hbox {T}$$ 7 T Bruker BioSpec 70/30 Ultra Shield Refrigerated Magnetic Resonance Imaging (MRI) system.
Pascal Bebié   +5 more
doaj   +5 more sources

Comments on the NEMA NU 4-2008 Standard on Performance Measurement of Small Animal Positron Emission Tomographs [PDF]

open access: yesEJNMMI Physics, 2020
The National Electrical Manufacturers Association’s (NEMA) NU 4-2008 standard specifies methodology for evaluating the performance of small-animal PET scanners.
Patrick Hallen   +2 more
doaj   +6 more sources

Performance evaluation of the ACTIVE 7 MAX benchtop preclinical PET scanner in accordance with the NEMA NU 4-2008 standard [PDF]

open access: yesEJNMMI Physics
Introduction ACTIVE 7 MAX is a compact benchtop preclinical PET scanner dedicated to high sensitivity and high-resolution imaging of small animals.
Haihao Wang   +10 more
doaj   +4 more sources

NEMA NU 4-2008 comparison of preclinical PET imaging systems. [PDF]

open access: yesJ Nucl Med, 2012
The National Electrical Manufacturers Association (NEMA) standard NU 4-2008 for performance measurements of small-animal tomographs was recently published. Before this standard, there were no standard testing procedures for preclinical PET systems, and manufacturers could not provide clear specifications similar to those available for clinical systems ...
Goertzen AL   +18 more
europepmc   +5 more sources

Performance based on NEMA NU-4 2008 Standard of CDTN/CNEN’s Small Animal PET Scanner

open access: yesBrazilian Journal of Radiation Sciences, 2022
This study aimed to evaluate the general performance of the preclinical PET scanner (LabPET Solo 4, GE) at CDTN/CNEN using the NEMA NU 4-2008 protocol.
Rodrigo Modesto Gadelha Gontijo   +3 more
doaj   +2 more sources

Image quality assessment using NEMA NU 4/2008 standards in small animal PET scanner

open access: yesBrazilian Journal of Radiation Sciences, 2019
In Brazil, there are few microPET in use and a quality control protocols standardization are needed to harmonize their use in the research field. Thus, the purpose of this study is to characterize the image quality performance of the microPET scanner ...
Rodrigo Modesto Gadelha Gontijo   +3 more
doaj   +6 more sources

Performance evaluation of the IRIS XL-220 PET/CT system, a new camera dedicated to non-human primates [PDF]

open access: yesEJNMMI Physics, 2022
Background Non-human primates (NHP) are critical in biomedical research to better understand the pathophysiology of diseases and develop new therapies. Based on its translational and longitudinal abilities along with its non-invasiveness, PET/CT systems ...
Frédéric Boisson   +13 more
doaj   +2 more sources

NEMA characterization of the SAFIR prototype PET insert [PDF]

open access: yesEJNMMI Physics, 2022
Background The SAFIR prototype insert is a preclinical Positron Emission Tomography (PET) scanner built to acquire dynamic images simultaneously with a 7 T Bruker Magnetic Resonance Imaging (MRI) scanner.
Parisa Khateri   +4 more
doaj   +2 more sources

NEMA NU‐4 2008 performance evaluation of Xtrim‐PET: A prototype SiPM‐based preclinical scanner [PDF]

open access: yesMedical Physics, 2019
PurposeXtrim‐PET is a newly designed Silicon Photomultipliers (SiPMs)‐based prototype PET scanner dedicated for small laboratory animal imaging. We present the performance evaluation of the Xtrim‐PET scanner following NEMA NU‐4 2008 standards to help optimizing scanning protocols which can be achieved through standard and reliable system performance ...
Habib Zaidi   +2 more
exaly   +7 more sources

Contrast-enhanced small-animal PET/CT in cancer research: strong improvement of diagnostic accuracy without significant alteration of quantitative accuracy and NEMA NU 4-2008 image quality parameters. [PDF]

open access: yesEJNMMI Res, 2013
Abstract Background The use of iodinated contrast media in small-animal positron emission tomography (PET)/computed tomography (CT) could improve anatomic referencing and tumor delineation but may introduce inaccuracies in the attenuation correction of the PET images.
Lasnon C   +5 more
europepmc   +4 more sources