Results 111 to 120 of about 542 (127)
Characterization and optimization of image quality as a function of reconstruction algorithms and parameter settings in a Siemens Inveon small-animal PET scanner using the NEMA NU 4-2008 standards [PDF]
Abstract The image reconstruction algorithms provided with the Siemens Inveon small-animal PET scanner are filtered backprojection (FBP), 3-dimensional reprojection (3DRP), ordered subset expectation maximization in 2 or 3 dimensions (OSEM2D/3D) and maximum a posteriori (MAP) reconstruction. This study aimed at optimizing the reconstruction parameter
Eric P Visser +2 more
exaly +2 more sources
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Physics in Medicine and Biology, 2022
Abstract An avalanche photodiode (APD)-based small animal positron emission tomography (PET)-insert was fully evaluated for its PET performance, as well as potential influences on magnetic resonance imaging (MRI) performance. This PET-insert has an extended axial field of view (FOV) compared with the previous design to increase system ...
Jonathan A Disselhorst +2 more
exaly +3 more sources
Abstract An avalanche photodiode (APD)-based small animal positron emission tomography (PET)-insert was fully evaluated for its PET performance, as well as potential influences on magnetic resonance imaging (MRI) performance. This PET-insert has an extended axial field of view (FOV) compared with the previous design to increase system ...
Jonathan A Disselhorst +2 more
exaly +3 more sources
Performance Evaluation of a PEM Scanner Using the NEMA NU 4—2008 Small Animal PET Standards
IEEE Transactions on Nuclear Science, 2010The recently published NEMA NU 4-2008 Standards has been specially designed for evaluating the performance of small animal PET scanners used in preclinical applications. In this paper, we report on the NU 4 performance of a clinical positron emission mammography (PEM) system. Since there are no PEM specific performance test protocols available, and the
Weidong Luo +2 more
exaly +2 more sources
Performance evaluation of the small-animal PET scanner ClairvivoPET using NEMA NU 4-2008 Standards
Physics in Medicine and Biology, 2015The aim of this study was to evaluate the performance of ClairvivoPET using NEMA NU4 standards. The ClairvivoPET incorporates a LYSO dual depth-of-interaction detector system with 151 mm axial field of view (FOV). Spatial resolution, sensitivity, counting rate capabilities, and image quality were evaluated using NEMA NU4-2008 standards.
K, Sato +11 more
openaire +2 more sources
Molecular Imaging and Biology, 2016
The Tera-Tomo 3D image reconstruction algorithm (a version of OSEM), provided with the Mediso nanoScan® PC (PET8/2) small-animal positron emission tomograph (PET)/x-ray computed tomography (CT) scanner, has various parameter options such as total level of regularization, subsets, and iterations. Also, the acquisition time in PET plays an important role.
Anastasios Gaitanis +2 more
exaly +3 more sources
The Tera-Tomo 3D image reconstruction algorithm (a version of OSEM), provided with the Mediso nanoScan® PC (PET8/2) small-animal positron emission tomograph (PET)/x-ray computed tomography (CT) scanner, has various parameter options such as total level of regularization, subsets, and iterations. Also, the acquisition time in PET plays an important role.
Anastasios Gaitanis +2 more
exaly +3 more sources
Physics in Medicine and Biology, 2014
In this work a comparison between experimental and simulated data using GATE and PeneloPET Monte Carlo simulation packages is presented. All simulated setups, as well as the experimental measurements, followed exactly the guidelines of the NEMA NU 4-2008 standards using the microPET R4 scanner.
F D, Popota +7 more
openaire +2 more sources
In this work a comparison between experimental and simulated data using GATE and PeneloPET Monte Carlo simulation packages is presented. All simulated setups, as well as the experimental measurements, followed exactly the guidelines of the NEMA NU 4-2008 standards using the microPET R4 scanner.
F D, Popota +7 more
openaire +2 more sources
Performance evaluation of a small‐animal PET scanner with 213 mm axis using NEMA NU 4‐2008
Medical PhysicsAbstractBackgroundLong‐axis positron emission tomography (PET) has emerged as one of the recent research directions in PET due to its ability to significantly enhance sensitivity and counting performance for low‐dose imaging, rapid imaging, and whole‐body dynamic imaging.PurposeThe PET system presented in this study is a long‐axis animal PET based on ...
Qing, Wei +15 more
openaire +2 more sources
2023 IEEE Nuclear Science Symposium, Medical Imaging Conference and International Symposium on Room-Temperature Semiconductor Detectors (NSS MIC RTSD), 2023
P. L. Bebié +2 more
openaire +1 more source
P. L. Bebié +2 more
openaire +1 more source
Assessment of the easyPET-3D system performance: NEMA NU 4-2008 standards and animal model
A tomografia por emissão de positrão (PET, do inglês positron emission tomography) dedicada à imagiologia não-invasiva in vivo de modelos animais é uma ferramenta essencial nas atividades de investigação, contribuindo para a caracterização de modelos de patologias humanas, desenvolvimento e validação de novos medicamentos e radiofármacos, e avaliação ...openaire +1 more source