Results 41 to 50 of about 9,655 (184)

Interleukin-34 as a Robust Predictor of No-Reflow Phenomenon in ST-Elevation Myocardial Infarction: Insights into Inflammatory Mechanisms and Clinical Implications

open access: yesGazi Medical Journal
Objective: ST-elevation myocardial infarction (STEMI) poses a significant challenge despite advances in reperfusion strategies. The “no-reflow” phenomenon, characterized by inadequate microvascular blood flow restoration following successful ...
Mehdi Karasu   +2 more
doaj   +1 more source

Association of Total Ischemia Time with No-Reflow Phenomenon in Patients Presenting with STElevation Myocardial Infarction, Undergoing Primary Percutaneous Coronary Intervention

open access: yesPakistan Armed Forces Medical Journal, 2023
Objective: To find out the association of total ischemic time with no-reflow phenomenon, in terms of Thrombolysis in Myocardial Infarction (TIMI) flow grade, in patients presenting with ST-Elevation Myocardial Infarction and undergoing Primary ...
Waheed Ashraf   +7 more
doaj   +1 more source

Wireless, Adaptable and Fully Implantable Battery‐powered Devices for Optical Stimulation of the Spinal Cord in Small Rodents

open access: yesAdvanced Science, EarlyView.
Current technologies for spinal cord optogenetic stimulation rely on external power sources and face reliability constraints in freely behaving animals. Here, a fully implantable, battery‐powered optoelectronic device is introduced, enabling operation in any selected environment with wireless recharging for months‐long stimulation.
Shahriar Shalileh   +8 more
wiley   +1 more source

Impedance‐Matched High‐Overtone Thickness‐Shear Bulk Acoustic Resonators With Scalable Mode Volume

open access: yesAdvanced Science, EarlyView.
A bottom‐electrode‐free high‐overtone bulk acoustic resonator is achieved by lateral excitation of antisymmetric thickness‐shear modes on a lithium‐niobate‐on‐silicon platform. Planar electrode geometry eliminates conventional loading along the resonance path and confines acoustic energy within the electrode gap.
Zi‐Dong Zhang   +7 more
wiley   +1 more source

Electric‐Current‐Induced Phase Transformation in Cu6Sn5 Below Its Equilibrium Transition Temperature

open access: yesAdvanced Science, EarlyView.
Electric current induces a monoclinic‐to‐hexagonal phase transformation in Cu6Sn5 at a measured bulk temperature of ∼120°C, below the equilibrium transition temperature. Ex situ synchrotron x‐ray diffraction, TEM, and matched thermal controls show that current stressing promotes the formation of a retained hexagonal η‐phase post‐stress state not ...
Shih‐kang Lin   +3 more
wiley   +1 more source

Evaluation of the clinical and procedural predictive factors of no-reflow phenomenon following primary percutaneous coronary intervention

open access: yesResearch in Cardiovascular Medicine, 2015
Background: The no-reflow phenomenon is an uncommon and critical occurrence which myocardial reperfusion does not restore to its optimal level. Several predisposing factors of the no-reflow phenomenon have been identified.
Seifollah Abdi   +4 more
doaj   +1 more source

A nomogram risk prediction model for no-reflow after primary percutaneous coronary intervention based on rapidly accessible patient data among patients with ST-segment elevation myocardial infarction and its relationship with prognosis

open access: yesFrontiers in Cardiovascular Medicine, 2022
BackgroundNo-reflow occurring after primary percutaneous coronary intervention (PCI) in patients with ST-segment elevation myocardial infarction (STEMI) can increase the incidence of major adverse cardiovascular events (MACE).
Yehong Liu   +9 more
doaj   +1 more source

Bridging Performance and Fate: A Framework for Sustainable, Composite‐Based Flexible Electronic Systems

open access: yesAdvanced Electronic Materials, EarlyView.
Composite‐based flexible electronics integrate biodegradable polymers, conductive networks, and multilayer device architectures to balance electrical performance, mechanical durability, and controlled degradation. Interfacial engineering and encapsulation regulate transport stability and operational lifetime, while programmed disassembly enables ...
Sayam, Sangho Cho
wiley   +1 more source

The predictors of no reflow phenomenon after percutaneous coronary intervention in patients with ST elevation myocardial infarction: A meta-analysis

open access: yesIndian Heart Journal, 2018
Objective: To investigate the no reflow risk factors after percutaneous coronary intervention in ST elevation myocardial infarction patients. Method: Sample size, mean ± standard deviation (SD) or frequencies (percent) of normal and no reflow groups were
Jonny Karunia Fajar   +2 more
doaj   +1 more source

Modular Electronic Microrobots With Onboard Sensor‐Program‐Steered Locomotion

open access: yesAdvanced Intelligent Systems, EarlyView.
Modular electronic smartlet microrobots integrate ambient‐light energy harvesting, photodetection, programmable CMOS control, and bubble‐based actuation within a sub‐millimeter fold‐up architecture. A 58‐bit on‐board CMOS chiplet enables sensor–program steered switching between independently addressable actuators, achieving closed‐loop 2D navigation in
Vineeth K. Bandari   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy