Results 51 to 60 of about 21,710,721 (213)
Composite‐based flexible electronics integrate biodegradable polymers, conductive networks, and multilayer device architectures to balance electrical performance, mechanical durability, and controlled degradation. Interfacial engineering and encapsulation regulate transport stability and operational lifetime, while programmed disassembly enables ...
Sayam, Sangho Cho
wiley +1 more source
ABSTRACT Background In patients with acute coronary syndrome (ACS) and multivessel disease (MVD), complete revascularization (CR) improves clinical outcomes compared with culprit‐only percutaneous coronary intervention (PCI). However, the optimal timing of CR, immediate (ICR) versus staged (SCR), remains debated.
Alessandro Gabrielli +7 more
wiley +1 more source
Background: The no-reflow phenomenon is an uncommon and critical occurrence which myocardial reperfusion does not restore to its optimal level. Several predisposing factors of the no-reflow phenomenon have been identified.
Seifollah Abdi +4 more
doaj +1 more source
Coronary Perforation During Excimer Laser Angioplasty in a Patient With Prior Thoracic Radiotherapy
ABSTRACT Background Management of heavily calcified coronary lesions remains challenging despite advances in plaque‐modifying technologies. Excimer laser coronary angioplasty (ELCA) is an effective adjunctive strategy with a low risk of no‐reflow. Case Summary A 75‐year‐old woman with non–ST‐segment elevation acute coronary syndrome and severe left ...
Francesco Maria Sparasci +3 more
wiley +1 more source
Clinical Outcomes of Drug‐Eluting Stents and Drug‐Coated Balloons in Tortuous Small Coronary Lesions
ABSTRACT Background In small, tortuous coronary lesions, the long‐term comparative performance of drug‐coated balloon (DCB) angioplasty versus drug‐eluting stent (DES) treatment remains uncertain, despite both strategies being widely used in contemporary percutaneous coronary intervention (PCI) practice. Aims This study aimed to compare 3‐year clinical
Shunichiro Ishio +6 more
wiley +1 more source
Wettability study of lead free solder paste and its effect towards multiple reflow
Nowadays, wafer bumping using solder paste has come into focus as it provides a low cost method. However, since the industries are moving towards lead-free electronic packaging, a new type of no-clean flux was produced specifically for lead-free solder ...
Idris Siti Rabiatull Aisha +2 more
doaj +1 more source
Objective: To investigate the no reflow risk factors after percutaneous coronary intervention in ST elevation myocardial infarction patients. Method: Sample size, mean ± standard deviation (SD) or frequencies (percent) of normal and no reflow groups were
Jonny Karunia Fajar +2 more
doaj +1 more source
ABSTRACT Background Limited data are available on the use of intravascular ultrasound (IVUS) in patients presenting with ST‐segment elevation myocardial infarction (STEMI). Aims This study aimed to assess the impact of IVUS‐guided primary percutaneous coronary intervention (PCI).
Frederik T. W. Groenland +13 more
wiley +1 more source
Background: Acute myocardial infarction (AMI) constitutes a major health problem with high mortality rates worldwide. In patients with ST-segment elevation myocardial infarction (STEMI), no-reflow phenomenon is a condition that adversely affects response
Halil Fedai +8 more
doaj +1 more source
ABSTRACT Background Intravascular lithotripsy (IVL) has emerged as an effective technique for modifying heavily calcified coronary plaques, facilitating optimal stent expansion while minimizing procedural complications. However, data on periprocedural myocardial injury (PMI) and infarction (PPMI) following IVL remain scarce.
Gwaenaelle Aellen +5 more
wiley +1 more source

