Comparison of Non-contact Tonometry and Goldmann Applanation Tonometry Measurements in Non-pathologic High Myopia [PDF]
PurposeTo compare intraocular pressure (IOP) values obtained using Goldmann applanation tonometry (IOPGAT) and non-contact tonometry (IOPNCT) in a non-pathologic high myopia population.MethodsA total of 720 eyes from 720 Chinese adults with non ...
Fengbin Lin, Weijing Cheng, Yunhe Song
exaly +4 more sources
A detailed methodology to model the Non Contact Tonometry: a Fluid Structure Interaction study [PDF]
Understanding the corneal mechanical properties has great importance in the study of corneal pathologies and the prediction of refractive surgery outcomes. Non-Contact Tonometry (NCT) is a non-invasive diagnostic tool intended to characterize the corneal
Elena Redaelli +6 more
doaj +2 more sources
Ocular surface displacement with and without contact lenses during non-contact tonometry. [PDF]
PurposeTo evaluate the displacement of the central ocular surface during non-contact tonometry with and without soft contact lenses and determine the factors associated with the displacement of the central ocular surface and intraocular pressure (IOP ...
Ulfah Rimayanti +5 more
doaj +2 more sources
The influence of topical anesthetic and fluorescein on non-contact tonometry measurements using ultra-high-speed dynamic Scheimpflug [PDF]
This study aimed to investigate the effects of topical anesthetic and fluorescein drops on intraocular pressure (IOP), central corneal thickness (CCT) and biomechanical properties as measured by Corvis ST (CST-Oculus; Wezlar, Germany) in healthy eyes.
Marcelo Macedo +5 more
doaj +2 more sources
Coupled biomechanical response of the cornea assessed by non-contact tonometry. A simulation study. [PDF]
The mechanical response of the cornea subjected to a non-contact air-jet tonometry diagnostic test represents an interplay between its geometry, the corneal material behavior and the loading.
Miguel Á Ariza-Gracia +4 more
doaj +2 more sources
Corneal Biomechanical Assessment with Ultra-High-Speed Scheimpflug Imaging During Non-Contact Tonometry: A Prospective Review [PDF]
Pedro Manuel Baptista,1,2 Renato Ambrosio Jnr,3– 7 Luis Oliveira,1 Pedro Meneres,1,2 Joao Melo Beirao1,2 1Ophthalmology Department, Centro Hospitalar Universitário do Porto, Porto, Portugal; 2Instituto de Ciências Biomédicas ...
Baptista PM +4 more
doaj +2 more sources
Non-contact tonometry: predicting intraocular pressure using a material—corneal thickness—independent methodology [PDF]
Introduction: Glaucoma, a leading cause of blindness worldwide, is primarily caused by elevated intraocular pressure (IOP). Accurate and reliable IOP measurements are the key to diagnose the pathology in time and to provide for effective treatment ...
Elena Redaelli +6 more
doaj +2 more sources
Comparison of intraocular pressure measured by Goldman applanation tonometer, noncontact tonometer and trans-palpebral tonometer [PDF]
Background To evaluate reliability and agreement of non-contact tonometry (NCT) and trans-palpebral tonometry (TPT) compared with Goldmann-applanation tonometry (GAT).
Madhu Thapa +3 more
doaj +2 more sources
Comparison of rebound tonometry and non-contact airpuff tonometry to Goldmann applanation tonometry
Purpose: The aim of this study was to compare the intraocular pressure measurements obtained from healthy subjects with the rebound tonometry, non-contact airpuff tonometry, and Goldmann applanation tonometry in different age groups.
Sevil Karaman Erdur +2 more
exaly +2 more sources
The influence of ocular parameters on intraocular pressure values measured by different devices and the development of an optimized prediction model in a myopic population [PDF]
Objective: To investigate the associations between ocular parameters—mean keratometry (Km), spherical equivalent (SE), central corneal thickness (CCT), axial length (AL), corneal hysteresis (CH), and corneal resistance factor (CRF)—and intraocular ...
Wei Gan +5 more
doaj +2 more sources