Results 11 to 20 of about 16,726,829 (263)

A simple technique for islanding detection with negligible non-detection zone [PDF]

open access: yes2009 IEEE Power & Energy Society General Meeting, 2009
Although active islanding detection techniques have smaller nondetection zones than passive techniques, active methods could degrade the system power quality and are not as simple and easy to implement as passive methods. The islanding detection strategy, proposed in this paper, combines the advantages of both active and passive islanding detection ...
H. Zeineldin, J. Kirtley
semanticscholar   +4 more sources

Islanding detection scheme for converter‐based DGs with nearly zero non‐detectable zone [PDF]

open access: yesIET Generation, Transmission & Distribution, 2019
This study presents a new method for detecting an islanding event in a microgrid with embedded converter-based distributed generation (DG). Unlike other schemes, the proposed scheme injects negligible perturbations into the microgrid after the generation
O. Gupta, M. Tripathy, V. Sood
semanticscholar   +2 more sources

Avoiding the Non-Detection Zone of Passive Loss-of-Mains (Islanding) Relays for Synchronous Generation by Using Low Bandwidth Control Loops and Controlled Reactive Power Mismatches [PDF]

open access: yesIEEE Transactions on Smart Grid, 2014
Generation connected to electrical distribution systems requires reliable and timely detection of loss of-mains (islanding). Passive loss of mains detection relays typically use measurements of parameters such as frequency, phase, and the magnitudes of ...
A. Roscoe, G. Burt, C. Bright
semanticscholar   +5 more sources

Sandia frequency shift parameter selection for multi-inverter systems to eliminate non-detection zone

open access: yesIET Renewable Power Generation, 2011
Among frequency drift islanding detection methods, Sandia frequency shift (SFS) is considered as one of the most effective methods in detecting islanding conditions for grid connected photovoltaic (PV) inverters. The performance of the SFS method during an islanding condition and its non-detection zone (NDZ) depends to a great extent on its parameters.
H. Zeineldin, S. Conti
semanticscholar   +2 more sources

Islanding Detection Methods and Challenges for Distribution Generation: A Technological Review

open access: yesIEEE Access
Islanding detection poses a significant technical challenge for the reliable operation of grid-connected photovoltaic (PV) systems, particularly as the deployment of distributed generation (DG) increases across modern power networks.
Farshad Aslani, Shuhui Li
doaj   +2 more sources

Proposed Sandia frequency shift for anti-islanding detection method based on artificial immune system

open access: yesAlexandria Engineering Journal, 2018
Sandia frequency shift (SFS) is one of the active anti-islanding detection methods that depend on frequency drift to detect an islanding condition for inverter-based distributed generation.
A.Y. Hatata   +2 more
doaj   +2 more sources

Angular symmetrical components-based anti-islanding method for solar photovoltaic-integrated microgrid

open access: yesAutomatika, 2023
This article examines how an innovative Angular Symmetrical Components of Voltages be applied to islanding detection and voltage unbalance factor estimation at a photovoltaic inverter-based distribution unit. Positive and Negative Sequence Components are
V. Arivumani, Sujatha Balaraman
doaj   +1 more source

Islanding Detection with Reduced Non-Detection Zones and Restoration by Reconfiguration

open access: yesEnergies, 2023
The development and use of PV (Photovoltaic), Wind, and Hydro-based Distributed Generation (DG) is presently on the rise worldwide for improving stability and reliability, and reducing the power loss in the distribution system with reduced emission of harmful gases.
Sowmya Ramachandradurai   +3 more
openaire   +2 more sources

Implementation and Critical Analysis of the Active Phase Jump with Positive Feedback Anti-Islanding Algorithm

open access: yesEnergies, 2022
The protection against the unintentional islanding of Grid-Tied inverters is an important electrical security issue addressed by the main Standards. This concern is justified in face of the fact that unintentional islanding can lead to abrupt variations ...
Ênio Costa Resende   +2 more
doaj   +1 more source

An Islanding Detection Technique for Inverter-Based Distributed Generation in Microgrids

open access: yesEnergies, 2020
This article proposes a new passive islanding detection technique for inverter-based distributed generation (DG) in microgrids based on local synchrophasor measurements.
Mazaher Karimi   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy