Results 21 to 30 of about 16,726,829 (263)
Microgrids are able to dispatch power to distribution systems with the advancement of power electronics-based inverters. As per IEEE-1547-2018 standards, Microgrid has to maintain voltage of 0.88 < V < 1.1 p.u (per unit) and frequency of 58.8< f_0 < 61.2
Bangar Raju Lingampalli +1 more
doaj +1 more source
Intelligent Islanding Detection of Microgrids Using Long Short-Term Memory Networks
This paper presents a new intelligent islanding detection scheme (IIDS) based on empirical wavelet transform (EWT) and long short-term memory (LSTM) network to identify islanding events in microgrids.
Syed Basit Ali Bukhari +3 more
doaj +1 more source
Unintentional Passive Islanding Detection and Prevention Method with Reduced Non-Detection Zones
Islanding detection and prevention are involved in tandem with the rise of large- and small-scale distribution grids. To detect islanded buses, either the voltage or the frequency variation has been considered in the literature. A modified passive islanding detection strategy that coordinates the V-F (voltage–frequency) index was developed to reduce ...
Sowmya Ramachandradurai +2 more
openaire +2 more sources
This paper develops an islanding classification mechanism to overcome the problems of non-detection zones in conventional islanding detection mechanisms.
Ahteshamul Haque +5 more
doaj +1 more source
Non-invasive and non-contact automatic jaundice detection of infants based on random forest [PDF]
Jaundice is a common phenomenon in neonates and a significant cause of morbidity and mortality. Early detection of jaundice is still a significant challenge.
Ali Al-Naji +9 more
core +1 more source
Active islanding detection techniques majorly affect power quality due to injected harmonic signals, whereas passive methods have a large non-detection zone (NDZ).
Sareddy Venkata Rami Reddy +4 more
doaj +1 more source
Automatic non-volcanic tremor detection in the Mexican subduction zone [PDF]
Desarrollo de un algoritmo de detección de tremores no-volcánicos (TNV). Un TNV ocurre en el rango de frecuencia de 1 – 10 Hz, pero el ruido ambiental alto ocurre por encima de los 2 Hz en muchas de las estaciones del MesoAmerican Seismic Experiment ...
Allen Husker +3 more
doaj +2 more sources
RFMFA Technique for Islanding Detection Scheme in Integrated DG System
EEE 1547 specifies time limits for the completion of DG interconnection tasks, and one of these tasks is the detection of islanding, which must be completed within two seconds of the task's start.
Katta Venkata Reddy, Tharun Kommaddi
doaj +1 more source
DG System Using PFNN Controllers for Improving Islanding Detection and Power Control
In this study, an intelligent controlled distributed generator (DG) system is proposed for tracking control and islanding detection. First, a DC/AC inverter with DC power supply is adopted to emulate a DG system and control the active and reactive power ...
Kuang-Hsiung Tan, Chien-Wu Lan
doaj +1 more source
A comprehensive literature review of conventional and modern islanding detection methods
Distributed Energy Resources (DER) offer significant advantages by means of raising reliability of distribution system, providing clean source of electricity and reduction in fossil fuel consumption.
Nauman Ali Larik +4 more
doaj +1 more source

