Results 191 to 200 of about 472,625 (280)
Some of the next articles are maybe not open access.
Open-Circuit Fault Diagnosis of NPC Inverter Based on Improved 1-D CNN Network
IEEE Transactions on Instrumentation and Measurement, 2022With the increasing popularization of a three-level neutral point clamped (NPC) inverter, realizing an accurate and fast fault diagnosis is also required.
Weibo Yuan +5 more
semanticscholar +1 more source
IEEE Journal of Emerging and Selected Topics in Power Electronics, 2022
Three-level neutral-point-clamped (NPC) inverter is used in many industrial applications due to its attractive advantages in terms of harmonics content, achieved power level, and electromagnetic interference reduction.
A. Zorig, S. Barkat, A. Sangwongwanich
semanticscholar +1 more source
Three-level neutral-point-clamped (NPC) inverter is used in many industrial applications due to its attractive advantages in terms of harmonics content, achieved power level, and electromagnetic interference reduction.
A. Zorig, S. Barkat, A. Sangwongwanich
semanticscholar +1 more source
IEEE Journal of Emerging and Selected Topics in Power Electronics, 2023
Due to the open-circuit fault of neutral-point-clamped (NPC) inverter having the characteristics of solid concealment and multiple fault modes, it is necessary to study an accurate and efficient fault diagnosis method to detect and locate the fault in ...
Feng Xie +5 more
semanticscholar +1 more source
Due to the open-circuit fault of neutral-point-clamped (NPC) inverter having the characteristics of solid concealment and multiple fault modes, it is necessary to study an accurate and efficient fault diagnosis method to detect and locate the fault in ...
Feng Xie +5 more
semanticscholar +1 more source
Adaptive Dead-Time Compensation for High-Frequency Three-Level Sparse NPC Inverter
IEEE Journal of Emerging and Selected Topics in Power Electronics, 2023A promising three-level (3L) topology for ultrahigh-speed (UHS) motor applications is a sparse neural point clamped (SNPC) inverter that can generate 3L voltage output and is the cheapest among other 3L counterparts.
Aleksandr Sheianov, Xi Xiao, Xudong Sun
semanticscholar +1 more source
Cascaded Transformers-Based Multilevel Inverters With NPC
IEEE Transactions on Industrial Electronics, 2022The basic structure and generalization of two cascaded transformer multilevel inverters (CTMIs) are proposed in this paper. Such configurations are based on cascaded symmetrical transformers coupled to two-level (2L) legs and three-level (3L) neutral-point clamped (NPC) legs. One configuration has a shared 2L leg, connected to all transformers.
Amanda Pereira Monteiro +3 more
openaire +1 more source
IEEE transactions on power electronics, 2022
In this article, a novel pulsewidth modulation (PWM) technique is proposed for an existing space vector hysteresis current controller (SVHCC) scheme.
R. Chavali, A. Dey, B. Das
semanticscholar +1 more source
In this article, a novel pulsewidth modulation (PWM) technique is proposed for an existing space vector hysteresis current controller (SVHCC) scheme.
R. Chavali, A. Dey, B. Das
semanticscholar +1 more source
IEEE transactions on power electronics, 2023
Neutral point clamped inverter (NPC) features low harmonics, high efficiency, and low voltage stress, et al. NPC is widely applied in renewable energy power generation systems, such as wind turbine power and photovoltaic. However, due to unbalanced power
Xiaobiao Wang +3 more
semanticscholar +1 more source
Neutral point clamped inverter (NPC) features low harmonics, high efficiency, and low voltage stress, et al. NPC is widely applied in renewable energy power generation systems, such as wind turbine power and photovoltaic. However, due to unbalanced power
Xiaobiao Wang +3 more
semanticscholar +1 more source
Design and Implementation of Three-phase Three Level NPC Inverter
2023 7th International Conference on Trends in Electronics and Informatics (ICOEI), 2023The three-level NPC PWM inverter is a type of multilevel inverter that provides a higher quality of output wave form compared to traditional two-level inverter.
D. G +5 more
semanticscholar +1 more source
Optimal design of NPC and Active-NPC transformerless PV inverters
2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG), 2012Targeting at a cost-effective deployment of grid-connected PhotoVoltaic (PV) systems, this paper presents a new methodology for the optimal design of transformerless PV inverters, which are based on the Neutral Point Clamped (NPC) and the Active-Neutral Point Clamped (ANPC) topologies. The design optimization results demonstrate that a different set of
S. Saridakis +2 more
openaire +2 more sources
IEEE Journal of Emerging and Selected Topics in Power Electronics, 2022
The reduction in the cost of photovoltaic (PV) energy is still required to be competitive as an alternative energy source. The efficiency and reliability of PV inverters are important aspects to be enhanced to reduce the cost of PV energy since it is ...
U. Choi, June-Seok Lee
semanticscholar +1 more source
The reduction in the cost of photovoltaic (PV) energy is still required to be competitive as an alternative energy source. The efficiency and reliability of PV inverters are important aspects to be enhanced to reduce the cost of PV energy since it is ...
U. Choi, June-Seok Lee
semanticscholar +1 more source

